Illustration 19.624.010 (A)
Trash Enclosure Requirements for 3 cubic yard bin
| |
---|---|
Alternate A
|
Access / Location Requirements:
|
• Locate trash area(s) with convenient accessibility
for both deposit and pick-up.
| |
• Location(s) shall be approved by the Planning
Division.
| |
• Provide a side or rear access door/gate for
multi-tenant uses.
| |
• Provide a 7 foot high overhead door for trash
pick-up service, with standard garage door hardware and construction.
| |
Construction Requirements:
| |
• Provide 6 inch reinforced block wall construction.
| |
• Provide a 4 inch P.C.C. pad, flush with adjacent
driveway.
| |
• Structural details shall be approved by the
Building Division.
| |
• Provide a 6 inch wide, 8 inch high concrete
curb at base of interior walls for protection of walls from trash
bin.
| |
Design / Finish:
| |
• Block walls shall be of decorative finish
compatible with adjacent structures or walls.
| |
• Decorative beams or other appropriate screening
material shall be provided across the open top to screen trash area
from view from 2nd and 3rd stories.
| |
Note:
| |
• Deviations from these standards may be considered
at the discretion of the Director.
|
Illustration 19.624.010 (B)
Trash Enclosure Requirements for 3 cubic yard bin
| |
---|---|
Alternate B
|
Access / Location Requirements:
|
• Locate trash area(s) with convenient accessibility
for both deposit and pick-up.
| |
• Location(s) shall be approved by the Planning
Division.
| |
• Locate enclosure(s) 4 foot back from adjacent
driveways and parking stalls to preclude gates from swinging out into
vehicles.
| |
Construction Requirements:
| |
• Provide 6 inch reinforced block wall construction.
| |
• Provide a 4 inch P.C.C. pad, flush with adjacent
driveway.
| |
• Structural details shall be approved by the
Building Division.
| |
• Provide a 6 inch wide, 8 inch high concrete
curb at base of interior walls for protection of walls from trash
bin.
| |
• Construct door frames from welded 2 inch
square metal tubing or 2.5 inch angle iron.
| |
• Heavy-duty hinges with a 180 degree swing
shall be welded to door frames and to 2.5 inch square metal tube posts
of a minimum 1/4 inch thickness set in concrete footings.
| |
Design / Finish:
| |
• Block walls shall be of decorative finish
compatible with adjacent structures or walls.
| |
• Material covering door frames shall be durable
and compatible with adjacent buildings. (chainlink and grapestake
are not permitted)
| |
Note:
| |
• Deviations from these standards may be considered
at the discretion of the Director.
|