Table 3-8
Off-Street Parking Space Requirements
| |
---|---|
Land Use
|
Number of Spaces Required
|
Residential Uses
| |
Accessory dwelling units
|
1 space per ADU.
|
Short-term rentals
|
1 space per short-term rental, and the parking space requirements
per single-family dwelling as specified below.
|
Mobile home park or trailer park
|
2 spaces for each unit or 1 space for seniors (62 years or older),
plus 1 guest space for every 5 units; spaces may be tandem.
|
Multi-family
|
1 1/4 spaces per 1 bedroom, 2 spaces for each unit having
2-4 bedrooms, or 3 spaces for 5 or more bedrooms or rooms which could
be used as bedrooms, plus 1 guest space for every 5 units. At least
1 space for each unit shall be covered with a garage or carport.
|
Single- and two-family dwelling
|
2 spaces per dwelling unit with up to 4 bedrooms, dwelling units
with 5 or more bedrooms require 3 spaces at least 1 of which shall
be a covered garage or carport (each space must be at least 9 feet
by 19 feet).
|
Single room occupancy (SRO)
|
1 space per unit or bedroom, 1 space for an on-site manager
where applicable, and 1 space for each additional employee.
|
Recreation, Education, and Public Assembly Uses
| |
Assisted living facility
|
1/2 space per residential unit, plus 1 space per every shift
employee.
|
Colleges; art, craft, music, and dancing schools; and business,
professional and trade schools
|
1 space for every employee, plus 1 space for every 4 students
at planned capacity or 1 space for every 4 auditorium seats, whichever
is greater.
|
Commercial indoor and outdoor recreation
|
1 space for every 4 persons of allowed maximum facility capacity
or occupancy.
|
Convalescent homes, nursing homes, and sanitariums
|
1 space per staff or visiting doctor, plus one space per 2 employees,
plus 1 space for every 4 beds.
|
Day care centers
|
1 space for every employee, plus 2 spaces, plus 1 loading space
for every 5 children.
|
Day care homes
|
2 spaces per dwelling unit, at least 1 space of which shall
be a covered garage or carport.
|
Elementary schools
|
1 space for every employee, plus 1 3/4 spaces for each
classroom, plus a bus loading area.
|
Emergency shelters
|
1 space per 10 occupants, plus 1 space for each staff member.
|
Golf course and driving range
|
4 spaces for each hole on the course, and 1 space for each tee
driving range.
|
Hospitals
|
1 space for every 3 beds, plus 1 space per staff doctor, plus
1 space for every 3 staff.
|
Library
|
1 space for every 250 square feet of gross floor area, plus
1 space per every 5 seats in meeting rooms.
|
Middle and high schools
|
1 space for every employee, plus 2 1/2 spaces for each
classroom, plus a bus loading area.
|
Park and recreational use
|
1 space for every 5,000 square feet of active recreational area
within a park or playground.
|
Places of assembly
|
1 space for every 4 seats or 1 space for every 50 square feet
of net floor area for assembly, whichever is greater.
|
Theater, auditorium, sports arena, stadium, gymnasium
|
1 space for every 5 permanent seats or 40 square feet of gross
floor area, whichever is greater, plus 1 space for each shift employee.
|
Value added agricultural uses and activities (e.g., agricultural
tourism, agricultural retail, equestrian facilities)
|
1 space for each 225 square feet of gross retail floor area,
plus 1 space for every 2 shift employees, plus at least 1 space for
each truck associated with the operation.
|
Retail Uses
| |
All other professional offices
|
1 space per 250 square feet of gross floor area.
|
Banks, lending agencies, financial and governmental institutions,
public utility offices (including drive-up facilities)
|
1 space per 250 square feet of gross floor area.
|
Boat sales, mobile home sales, retail nurseries, and other open
uses not in a structure
|
1 space for every 3,000 square feet of gross floor area, 1 space
for each facility vehicle, plus 1 space for each employee. There shall
be a minimum of 4 spaces.
|
Food establishments with take-out provisions only
|
1 space for every 200 square feet of gross floor area, 1 space
for each facility vehicle, plus 1 space for each shift employee. There
shall be a minimum of 4 spaces.
|
Hotel and motels
|
1 space per guestroom, plus an additional 6 spaces.
|
Medical, dental, optometry, veterinarian, or chiropractic offices
and clinics
|
1 space per 250 square feet of gross floor area, or 6 spaces
per doctor, whichever is less.
|
Research facilities
|
1 space per 300 square feet of gross floor area.
|
Restaurant, cafe, night club, tavern, and other similar places
where food or refreshments are dispensed
|
1 space for every 3 seats or 100 square feet of gross floor
area devoted to dining, whichever is greater, plus 1 space for each
shift employee.
|
Restaurant with take-out service, walk-up, or drive-up windows
and roadside stands
|
1 space for every 3 seats or 100 square feet of gross floor
area, whichever is greater, plus 1 space for each shift employee,
plus 8 spaces or 8 auto waiting spaces for each exterior service window.
|
Retail uses of any type, unless otherwise listed below
|
1 space for every 250 square feet of gross floor area.
|
Service stations and vehicle repair
|
1 space per 400 square feet of gross floor area, plus 1 space
for each employee, but not less than 3 spaces total (service bays
shall not be counted as part of the required parking).
|
Shopping centers (projects over 200,000 square feet of gross
floor area)
|
1 space per 275 square feet of gross floor area.
|
Temporary or limited term produce stand (selling products grown
on the property)
|
1 space for each 225 square feet of gross retail floor area,
plus 1 space for every 2 shift employees, plus at least 1 space for
each truck associated with the operation.
|
Vehicle sales and repair
|
1 space for every 400 square feet of gross floor area.
|
Industrial Uses
| |
Industrial uses of any type, unless listed below, including
warehouses or structures used exclusively for storage purposes
|
1 spaces for each 1,000 square feet of gross floor area, plus
1 space for each facility vehicle.
|
Machinery sales and wholesale stores
|
1 space for every 800 square feet of gross floor area.
|
Public facility (e.g., communication equipment structure or
electrical substation)
|
1 space for every shift employee.
|
Truck/car wash and maintenance facility
|
1 1/2 spaces per service bay, plus 1 space per every shift
employee.
|
Table 3-9
ADA Parking Space Requirements
| |
---|---|
Number of Off-Street Vehicle Spaces Provided
|
Minimum Number of ADA Accessible Parking Spaces Required
|
1-40
|
1
|
41-80
|
2
|
81-120
|
3
|
121-160
|
4
|
161-300
|
5
|
301-400
|
6
|
401-500
|
7
|
Over 500
|
One for each 200 additional spaces
|
Table 3-10
Minimum Off-Street Parking Dimensions
| ||||
---|---|---|---|---|
Parking Angle
(degrees)
|
Space Width
(feet)
|
Curb Length
(feet)
|
Space Depth
(feet)
|
Drive Aisle
(feet)
|
0 (Parallel)
|
9
|
22
|
9
|
14
|
30
|
9
|
N/A
|
18
|
14
|
45
|
9
|
N/A
|
20
|
15
|
60
|
9
|
N/A
|
21
|
18
|
90
|
9
|
N/A
|
19
|
24 (two-way aisle)
|
Table 3-11
Electric and Alternative Fuel Vehicle Parking Space Requirements
| |
---|---|
Number of Off-Street Vehicle Spaces Provided
|
Minimum Number of Electric and Alternative Fuel Vehicle Parking
Spaces Required
|
1-9
|
None Required
|
10-25
|
1
|
26-50
|
3
|
51-75
|
6
|
76-100
|
8
|
101-150
|
11
|
151-200
|
16
|
Over 200
|
At least 8% of the total number of vehicle spaces
|
Table 3-12
Motorcycle Parking Requirements
| ||
---|---|---|
Use
|
Number of Off-Street Vehicle Spaces Provided
|
Minimum Number of Motorcycle Parking Spaces Required
|
Commercial
|
1-25 spaces
|
None required
|
26-50 spaces
|
1 space
| |
50-100 spaces
|
2 spaces
| |
Greater than 100 spaces
|
2 spaces, plus 1 space for each 100 vehicle spaces
| |
Residential
|
1-6
|
None required
|
Greater than 6 spaces
|
½ space for every 6 vehicle spaces for more than two
dwelling units
|
Table 3-13
Off-Street Loading Requirements
| ||
---|---|---|
Use
|
Gross Floor Area
|
Loading Spaces Required
|
Commercial and Mixed-Use Uses Including Hospitals and
Institutions
|
Less than 3,500
|
0
|
3,500 – 15,000
|
1
| |
15,001 – 40,000
|
2
| |
40,001 – 80,000
|
3
| |
80,001 – 100,000
|
4
| |
Greater than 100,000
|
5
| |
Hotels and Offices
|
Less than 3,500
|
0
|
3,500 – 40,000
|
1
| |
40,001 – 100,000
|
2
| |
Greater than 100,000
|
3
| |
Industrial Uses
|
Less than 3,500
|
0
|
3,500 – 40,000
|
1
| |
40,001 – 80,000
|
2
| |
80,001 – 100,000
|
3
| |
100,001 – 160,000
|
4
| |
Greater than 160,000
|
5
|