[Ord. No. O-25-2018, 7-12-2018; amended 8-8-2023 by Ord. No. O-11-2023]
The following regulations shall apply to all outdoor luminaires.
[Ord. No. O-25-2018, 7-12-2018; amended 8-8-2023 by Ord. No. O-11-2023]
a. 
Design standards.
1. 
Exterior light fixtures shall be dark sky compliant.
2. 
No exterior light source, including fixtures not mounted on the primary structure, shall be mounted higher than 12 feet measured from the actual grade immediately beneath the light source.
3. 
No flashing, laser, searchlight, strobe, tracing, pulsating, or neon exterior lighting is permitted.
4. 
No recreational court, including tennis courts, basketball courts, or sports courts shall be artificially illuminated after 10:00 p.m.
5. 
No outdoor light fixture shall be operated by a dusk-to-dawn timer or sensor, unless it is motion-sensor activated. Motion-sensor light fixtures shall be controlled to shut off after 10 minutes, and shall not be triggered by activity located off the property.
6. 
Lighting elements installed to illuminate windows shall not be directly visible by pedestrians or vehicles.
7. 
Public sidewalks classified as S2 or S3 shall conform to the Morristown Partnership Lighting Standards. See Appendix C for Morristown Partnership Lighting Standards specifications.[1]
[1]
Editor's Note: See § 30A-3.
[Ord. No. O-25-2018, 7-12-2018; amended 8-8-2023 by Ord. No. O-11-2023]
Outdoor lighting levels shall meet the standards in the following table:
Lighting Standard
Light Classification
LZ-1
LZ-2
LZ-3
Zones
R, Estate Overlay (R), MF-1, MF-2
PWN Overlay (MF-2), Critical Infrastructure (MF-2), MF-3, Neighborhood Overlay (MF-3), MX-1, Retail Overlay (MX-1), MX-2, TC, Transitional (TC) H, H-1
Large Lot Overlay (MX-2), Morristown Green Overlay (TC), Transit Overlay (TC), Headquarters Plaza Overlay (TC)
Maximum footcandles at property line
0.5 at property line; 2.0 at sidewalk frontage
0.5 at property line; 3.0 at sidewalk frontage
0.5 at property line; 3.0 at sidewalk frontage.
Sidewalks/public spaces (footcandles)
0.5 - 2
1 - 3
1 - 3
Parking/driveways (footcandles)
0.5 - 2
1 - 3
1 - 3
Nonresidential building entrances (permitted within 20 feet of entrance) (footcandles)
3 - 5
5 - 7.5
5 - 10
Primary residential entrance (fully shielded luminaire) (footcandles)
Maximum: 5
5 - 7.5
5 - 10
Other residential entrances (fully shielded luminaire) (footcandles)
Maximum: 3
5 - 7.5
5 - 7.5
Building facade lighting (footcandles)
Maximum: 3
Maximum: 5
Maximum: 10
Landscape lighting (each landscape lighting installation) (footcandles)
Maximum: 2
Maximum: 2
Maximum: 2
Outdoor dining (footcandles)
Maximum: 7
Maximum: 10
Maximum: 15
Bicycle parking (footcandles)
Maximum: 2
1 - 3
1 - 3
Note: