Lighting Standard
|
Light Classification
| ||
---|---|---|---|
LZ-1
|
LZ-2
|
LZ-3
| |
Zones
| |||
R, Estate Overlay (R), MF-1, MF-2
|
PWN Overlay (MF-2), Critical Infrastructure (MF-2), MF-3, Neighborhood
Overlay (MF-3), MX-1, Retail Overlay (MX-1), MX-2, TC, Transitional
(TC) H, H-1
|
Large Lot Overlay (MX-2), Morristown Green Overlay (TC), Transit
Overlay (TC), Headquarters Plaza Overlay (TC)
| |
Maximum footcandles at property line
|
0.5 at property line; 2.0 at sidewalk frontage
|
0.5 at property line; 3.0 at sidewalk frontage
|
0.5 at property line; 3.0 at sidewalk frontage.
|
Sidewalks/public spaces (footcandles)
|
0.5 - 2
|
1 - 3
|
1 - 3
|
Parking/driveways (footcandles)
|
0.5 - 2
|
1 - 3
|
1 - 3
|
Nonresidential building entrances (permitted within 20 feet
of entrance) (footcandles)
|
3 - 5
|
5 - 7.5
|
5 - 10
|
Primary residential entrance (fully shielded luminaire) (footcandles)
|
Maximum: 5
|
5 - 7.5
|
5 - 10
|
Other residential entrances (fully shielded luminaire) (footcandles)
|
Maximum: 3
|
5 - 7.5
|
5 - 7.5
|
Building facade lighting (footcandles)
|
Maximum: 3
|
Maximum: 5
|
Maximum: 10
|
Landscape lighting (each landscape lighting installation) (footcandles)
|
Maximum: 2
|
Maximum: 2
|
Maximum: 2
|
Outdoor dining (footcandles)
|
Maximum: 7
|
Maximum: 10
|
Maximum: 15
|
Bicycle parking (footcandles)
|
Maximum: 2
|
1 - 3
|
1 - 3
|
Note:
|
Given values reflect maximum average footcandles. Footcandles
shall be measured at four to five feet above the finished grade.
|