The purpose of this Chapter is to regulate lighting to balance
the safety and security needs for lighting with the City's desire
to preserve dark skies and to ensure that light trespass and glare
have negligible impact on surrounding property (especially residential)
and roadways.
(Ord. 1501 § 1, 2011)
The provisions of this Chapter apply to all new and existing
land uses, including permanent and temporary uses in all Zoning Districts.
(Ord. 1501 § 1, 2011)
Unless otherwise exempt by Section
17.50.040 (Exempt Lighting), all outdoor lighting fixtures for new multi-Family residential, commercial, industrial, mixed use, and public/quasi-public uses require Site Plan and Design Review approval by the designated Approving Authority pursuant to Section
17.10.060 (Site Plan and Design Review). Any retrofit or amendment to an existing site and/or building lighting that would have a measurable impact on abutting property or views from street right-of-way as determined by the Community Development Director shall require Site Plan and Design Review approval.
(Ord. 1501 § 1, 2011)
The following items shall be exempt from Design Review requirements:
A. All
outdoor light fixtures producing light directly by the combustion
of fossil fuels, such as kerosene lanterns or gas fixtures.
B. Temporary
lights used for holiday decorations.
C. Emergency
lighting erected for official purposes by local, state, or federal
agencies.
D. Lighting
for temporary uses and special events permitted consistent with this
Code.
(Ord. 1501 § 1, 2011)
The following types of lighting are prohibited:
A. Neon
tubing or band lighting along buildings and/or structures as articulation,
except as approved through Design Review and/or Master Sign Program.
B. Search
lights, laser source lights, or any similar high-intensity light,
except for emergency use by police or fire personnel or at their discretion,
or for approved temporary lighting for a special event approved by
the City.
C. Lighting
fixtures operated in such a manner as to constitute a hazard or danger
to persons or to safe vehicular travel.
D. Illumination
of entire buildings.
E. Roof-mounted
lighting except for security purposes.
F. Moving,
flashing, or animated lighting.
G. Light
poles that obstruct pedestrian traffic.
(Ord. 1501 § 1, 2011)
The following standards shall apply to all outdoor lighting.
A. Nuisance
Prevention. All outdoor lighting shall be designed, located, installed,
directed downward or toward structures, shielded, and maintained in
order to prevent glare, light trespass, and light pollution.
B. Maintenance.
Fixtures and lighting shall be maintained in good working order and
in a manner that serves the original design intent.
C. Shielding.
Except as otherwise exempt, all outdoor lighting shall be constructed
with full shielding and/or recessed to reduce light trespass to adjoining
properties. Each fixture shall be directed downward and away from
adjoining properties and public rights-of-way, so that no light fixture
directly illuminates an area outside of the site. Fixtures located
higher than 6 feet above the ground shall have shielding that limits
to angle of the cone of direct illumination to 60 degrees or less.
FIGURE 17.50.060-1: SHIELDING PROVISIONS FOR OUTDOOR LIGHTING
* Outdoor lighting shall be constructed with full shielding
and/or recessed to reduce light trespass to adjoining properties.
|
D. Level
of Illumination. Outdoor lighting shall be designed to illuminate
at the minimum level necessary for safety and security and to avoid
the harsh contrasts in lighting levels between the project site and
adjacent properties. Illumination standards are as follows:
1. Parking
lots, driveways, trash enclosures/areas, public phones, and group
mailboxes shall be illuminated with a minimum maintained 1 foot-candle
of light and an average not to exceed 4 footcandles of light. The
illumination shall not exceed 10 foot-candles in any one location.
2. Pedestrian
walkways shall be illuminated with a minimum maintained 0.5 foot-candle
of light and an average not to exceed 2 foot-candles of light.
3. Entryways
and exterior doors of nonresidential structures shall be illuminated
during the hours of darkness with a minimum maintained 1 foot-candle
of light, measured within a 5-foot radius on each side of the door
at ground level.
4. In
order to minimize light trespass on abutting residential property,
illumination measured at the nearest residential structure or rear
yard setback line shall not exceed the moon's potential ambient illumination
of one-tenth foot-candle.
E. Maximum
Height of Freestanding Outdoor Light Fixtures. The maximum height
of freestanding outdoor light fixtures shall be 20 feet. Height shall
be measured from the finish grade, inclusive of the pedestal, to the
top of the fixture.
F. Energy-Efficient
Fixtures Required. Outdoor lighting shall utilize energy-efficient
(high-pressure sodium, metal halide, low-pressure sodium, hard-wired
compact fluorescent, or other lighting technology that is of equal
or greater efficiency) fixtures and lamps. All new outdoor lighting
fixtures shall be energy efficient with a rated average bulb life
of not less than 10,000 hours.
G. Accent
Lighting. Architectural features may be illuminated by uplighting,
provided that the lamps are low intensity to produce a subtle lighting
effect and no glare or light trespass is produced. Where ever feasible,
solar-powered fixtures shall be used.
H. Signs. Lighting of signs shall be in compliance with Chapter
17.54 (Signs on Private Property) of this Code.
I. Sports
Fields/Outdoor Activity Areas. Where playing fields or other special
activity areas are to be illuminated, lighting fixtures shall be mounted,
aimed, and shielded so that the light falls within the primary playing
area and no significant off-site light trespass is produced. Additionally,
the lights shall be turned off within one hour after the end of the
event.
J. Telecommunications
Towers. Telecommunication towers and related equipment shall be unlit
except as provided below:
1. A
manually operated or motion-detector-controlled light above the equipment
shed door may be provided, except that the light shall remain off
except when personnel are present at night; and
2. The
minimum tower lighting required under FAA regulation; and
3. Where
tower lighting is required, said lighting shall be shielded or directed
downward to the greatest extent possible to ensure that such light
does not spill over onto abutting properties, especially residential
Zoning Districts or uses.
K. Alternative
Designs, Materials, and Installations. The designated Approving Authority
may grant approval of alternatives to this Section as part of a Site
Plan and Design Review permit.
(Ord. 1501 § 1, 2011)