The applicant shall submit the final plat and
street profiles clearly and legibly drawn in India ink on Mylar. These
shall be original drawings or prints on tracing cloth at a scale not
more than 100 feet to one inch. In addition to the tracing cloth drawing,
there shall be submitted four copies of the plans and profiles. The
final plat shall incorporate all of the information as required of
the preliminary plat and shall also include:
A. The proposed subdivision name or identifying title
and the name of the tract in which the subdivision is located; the
name and address of the record owner and applicant; the name, license
number and seal of the registered professional engineer and surveyor
or other designer.
B. Street lines, pedestrian ways, lots, reservations,
easements and areas dedicated to public use.
C. Sufficient data to determine readily the location,
bearing and length of every street, lot line, boundary line and to
reproduce such lines upon the ground.
D. The length and bearing of all straight lines, the
deflection angles, radii, length of curves and central angles of all
curves, tangent distances and tangent bearings shall be given for
each street. All dimensions of the lines of each lot shall be shown
in feet and decimals of a foot. The property boundaries, location,
scale and North points shall also be shown.
E. All offers of dedication with the certificate of approval
of the Town Attorney as to their legal sufficiency.
H. Figures showing the manhole stationing, size of sewers,
surface and sewer invert elevations at manholes and the grade of all
sewers between two adjacent manholes on the profiles.
I. Certification from the applicant's engineer that all
sewers are sufficiently deep to serve adjacent basements, except where
otherwise noted on the plans.
J. Record (as-built) drawings, certified by the applicant's
engineer, showing that sanitary sewers, storm drainage facilities,
manholes, house lateral stubs and all other underground facilities
were constructed by the applicant in accordance with the approved
final plat or in accordance with waivers thereof approved by the Planning
Board and to be submitted after subdivision is completed.
K. Certification of approval by the appropriate public
authority, when and where required, as well as such other certificates,
affidavits, endorsements or other agreements as may be required by
the Planning Board, in the enforcement of this chapter, to include,
but not limited to, the following:
(1) All Town Department heads concerned.
(2) Agencies of the County of Monroe under §§ 239-k,
239-1, 239-m and 239-n (of Article 12-B) of the General Municipal
Law.
(3) The State of New York Department of Transportation
(if applicable).
(4) The Monroe County Health Department.
(5) The Monroe County Water Authority or Sea Breeze and
Vicinity Water District.
(6) Rochester Gas and Electric Corporation.
(7) Rochester Telephone Corporation.
L. Planting. Adequate tree planting may be required of
the applicant. Street trees shall be a minimum of 35 feet and a maximum
of 50 feet on center. Tentative tree species shall be indicated on
the preliminary plan and shall be species which are not susceptible
to salt spray and thrive within the anticipated climatic conditions
of the location. Trees shall be northern-grown or locally grown and
certified disease- and pest-free. Trees shall not be less than 2 1/2
inches in diameter at the base at time of planting. They may be planted
on the owner's property only. Trees must be adequately supported by
guy wires until firmly rooted.
The following documents shall be submitted to
the town:
A. Ten copies of the final plat drawings.
B. Storm drainage computations.
C. Development grading plan.
D. Estimated construction schedule.
E. Engineers estimate for the letter of credit.