A.
Sanitary sewers.
(1)
Minimum requirements shall be as established by the New York State Department of Environmental Conservation, pursuant to Environmental Conservation Law § 17-0301, as amended or changed, and Title 8 of said law (Environmental Conservation Law § 17-0801 et seq., as amended or changed).
(2)
Sewer mains shall be a minimum of eight inches in diameter, except in those areas where the route within the development is part of the Master Sewer Plan. In these areas, the sewer shall be of the diameter called for in the Master Sewer Plan.
(3)
Manhole spacing shall be a maximum of 300 linear feet
(4)
The depth of the sewer shall provide for basement drainage (or slab construction) of all homes within the development. Where, because of topographic conditions, this provision cannot be met, the Plan shall incorporate a note specifying those lots which cannot be served in compliance with this requirement.
(5)
Elevations. Where storm drains are parallel the sanitary sewer system, a minimum of two feet of vertical clearance between the two systems shall be provided to permit the satisfactory installation of laterals.
B.
Sewage lift stations.
(1)
Specific geographic and/or topographic areas may require the use of sewage lift stations to transmit contributory flows to the trunk sewer system. Lift stations shall incorporate the following design requirements: