No person shall use or cause to be used any
hydrocyanic acid, cyanogen or cyanide gas for the purpose of fumigating
any building or other enclosed space in the City without a permit
from the Clerk or otherwise than in accordance with the terms of said
permit or the regulations as herein provided.
The rules and regulations governing the fumigation
of any building or enclosed space in the City by hydrocyanic acid,
cyanogen or cyanide gas shall be those adopted by the United States
Department of Agriculture.
Applications to use hydrocyanic acid, cyanogen
or cyanide gas for fumigating purposes shall be made on the blank
forms furnished by the Clerk. Permits issued as provided herein shall
remain in force until the 31st day of December, unless sooner revoked
by the Council.
It shall be the duty of every holder of a permit
issued in accordance with the provisions of this article to notify
the Police and Fire Departments of the City of the location of the
building or enclosed space to be fumigated, as well as its character
and use and the date and time when fumigation will be performed. This
notification shall be given as aforesaid at least 24 hours prior to
the commencement of such fumigation. No such fumigation shall be performed
unless the Police and Fire Departments have been notified in accordance
with the requirements of this regulation.
No building or enclosed space shall, during
the period of fumigation, be occupied by human beings. It shall be
the duty of the holder of the permit to make or cause to be made a
careful examination of all parts of such building or enclosed space
in order to verify that no human beings have remained therein and
that all necessary precautions have been undertaken to safeguard the
lives and health of all persons occupying buildings adjoining that
in which the fumigation is to be performed.
All crevices, cracks or openings in the building
or portion thereof fumigated leading to the outer air or into adjoining
buildings shall be effectively sealed so as to prevent the escape
of gas during the process of fumigation.
The materials used in fumigating shall be placed
in one or more receptacles of adequate size in the room or rooms to
be fumigated after all openings, except the one used for entry and
exit of the operator, are properly sealed. The operator placing the
sulfuric acid and cyanide shall be properly protected and safeguarded
by suitable properly tested mask and gloves. He alone shall be allowed
in the room or rooms to be fumigated during the placing of the chemicals
and until fumigation is completed and the premises are properly ventilated
and made safe for occupancy.
During the period fumigation is in process a
capable, alert watchman or watchmen shall remain on duty at the entrance
or entrances to the building or enclosed space fumigated and until
the fumigation is completed and the premises are properly ventilated
and made safe for occupancy.