ACPB
|
Allegheny County Plumbing Board, Secretary
Clack Health Center, Plumbing Division
39th Street and Penn Avenue
Pittsburgh, Pennsylvania 15224
| |
AHAM
|
Association of Home Appliance Manufacturers
20 North Wacker Drive
Chicago, Illinois 60606
| |
ANSI
|
American National Standards Institute
1430 Broadway
New York, New York 10018
| |
ARI
|
Air-Conditioning and Refrigeration Institute
1815 North Fort Meyer Drive, Suite 700
Arlington, Virginia 22209
| |
ASTM
|
American Society for Testing and Materials
1916 Race Street
Philadelphia, Pennsylvania 19103
| |
AWWA
|
American Water Works Association
6666 West Quincy
Denver, Colorado 30235
| |
ASME
|
American Society Mechanical Engineers
345 East 47th Street
New York, New York 10017
| |
ASSE
|
American Society of Sanitary Engineering
P.O. Box 40362
Bay Village, Ohio 44140
| |
CISPI
|
Cast Iron Soil Pipe Institute
1499 Chain Bridge Road
McLean, Virginia 22101
| |
FS
|
Federal Specifications, published by the Federal
Specifications Board. Obtainable from the Superintendent of Documents
United States Government Printing Office
Washington D.C. 20402
| |
NSF
|
National Sanitation Foundation
NSF Building
Ann Arbor, Michigan 48106
| |
PDI
|
Plumbing and Drainage Institute
5242 Boulevard Drive
Indianapolis, Indiana 46208
| |
PPI
|
Plastic Pipe Institute — a division of
the Society of the Plastic Industry, Inc.
355 Lexington Avenue
New York, New York 10017
| |
UL
|
Underwriters Laboratories, Inc.
355 Pfingsten Road
Northbrook, Illinois 60062
|
ABS
|
Acrylonitrile Butadiene Styrene
| |
PVC
|
Polyvinyl Chloride
| |
CPVC
|
Chlorinated Polyvinyl Chloride
| |
SPS
|
Standard Pipe Size
| |
SDR
|
Standard Dimensional Ration
| |
PR
|
Pressure Rated
| |
PE
|
Polyethylene
| |
PB
|
Polybutylene
| |
IBVM
|
Internal Back Vent System
| |
PW
|
Potable Water
| |
WD
|
Water Distribution
| |
DWV
|
Drainage, Waste, Vent
| |
SR
|
Styrene Rubber
| |
CW
|
Corrosion Waste
| |
MJ
|
Mechanical Joint
| |
CPE
|
Chlorinated Polyethylene
|
BOCA
|
Building Officials and Code Administrators International,
Inc.
4051 W. Flossmoor Road
Country Club Hills, Illinois 60477
| |
National Standard Plumbing Code
|
National Association of Plumbing Heating, Cooling
Contractors
P.O. Box 6808
Falls Church, Virginia 22046
| |
Southern Standard Plumbing Code
|
Building Code Congress
900 Montclair Road
Birmingham, Alabama 35203
| |
Uniform Plumbing Code
|
International Association of Plumbing and Mechanical
Officials
5032 Alhamnbra Avenue
Los Angeles, California 90032
|
EPA (state)
|
Environmental Protection Agency
Region III
841 Chestnut Building
Philadelphia, Pennsylvania 19107
| |
EPA (federal)
|
Environmental Protection Agency
1626 K Street, Northwest
Washington, D.C. 20460
| |
DER (state)
|
Department of Environmental Resources
Bureau of Community and Environmental Control
Box 2357
Second Floor Executive House
Harrisburg, Pennsylvania 17120
| |
DER
|
Department of Environmental Control
Bureau of Community and Environmental Control
Regional Office
600 Highland Building
121 S. Highland Avenue
Pittsburgh, Pennsylvania 15206
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Brass Pipe S.P.S.
|
All building classifications
|
H-27.1-67; B-43-80
|
ANSI; ASTM
| |
Copper Pipe S.P.S.
|
All building classifications
|
H-26.1-67; B-42-83
|
ANSI; ASTM
| |
Copper Tube — Types K & L; Types WK,
WL and WM
|
All building classifications
|
H-23.1-70; B-88-83
|
ANSI; ASTM
|
(2)
|
Cast Iron Pressure Pipe; Cast Iron Ductile Iron
Pipe
|
All building classifications
|
A-21.1-67; A-377-79; A-21.51-81
|
ANSI; ASTM; ANSI
| |
ABS Pipe: Schedules 40 & 80
|
All building classifications
|
D-1527-82; NSF No. 14
|
ASTM; NSF
|
(1)
|
ABS; SDR-PR Pipe
|
All building classifications
|
D-2282-83; NSF No. 14
|
ASTM; NSF
|
(1)
|
PVC Pipe: Schedules 40 80 & 120
|
All building classifications
|
D-1785-83; NSF No. 14
|
ASTM; NSF
|
(1)
|
PVC; SDR-PR PIPE
|
All building classifications
|
D-2241; NSF No. 14
|
ASTM; NSF
|
(1)
|
PVC; SDR-PR PIPE
|
All building classifications
|
D-2241; NSF No. 14
|
ASTM; NSF
|
(1)
|
PVC; Vinyl Iron
|
All building classifications
|
C-900-81
|
ANSI; AWWA
|
(1)
|
PVC Tubing
|
All building classifications
|
D-2740-76; NSF No. 14
|
ASTM; NSF
|
(1)
|
PE Pipe; SDR-PR — I.D.
|
All building classifications
|
D-2239-83; NSF No. 14
|
ASTM; NSF
|
(1)
|
PE Tubing
|
All building classifications
|
D-2737-83; NSF No. 14
|
ASTM; NSF
|
(1)
|
PB Pipe; PB Tubing
|
All building classifications
|
D-2666-83; NSF No. 14
|
ASTM; NSF
|
(1)
|
SDR-PR I.D.; PB Pipe
|
All building classifications
|
D-2662-83; NSF No. 14
|
ASTM; NSF
|
(1)
|
SDR-PR O.D.; PB Pipe
|
All building classifications
|
D-3000-73; NSF No. 14
|
ASTM; NSF
|
(1)
|
NOTES:
| |
---|---|
1.
|
All approved plastic pipe for potable water
transmission must bear National Sanitation Foundation NSF (P.W.) Seal
of Approval. Piping shall have a minimum working pressure of 160 PSI
at 73° F. Fittings, joining and installation methods shall comply
with Applicable Standards.
|
2.
|
Solders and fluxes used for the installation
or repair of potable water supply systems shall not contain more than
0.2% lead. Solder paste and flux shall conform to ASTM B-813.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Brass Pipe S.P.S.
|
All building classifications
|
H-27.1-67; B-43-80
|
ANSI; ASTM
| |
Copper Pipe S.P.S.
|
All building classifications
|
H-26.1-67; B-42-83
|
ANSI; ASTM
| |
Threadless Copper Pipe (TP)
|
All building classifications
|
H-26.1-73; B-302-82
|
ANSI; ASTM
| |
Copper Tube — Types K, L and M Types WK,
WL and WM
|
All building classifications
|
H-23.1-70; B-88-83
|
ANSI; ASTM
|
(1b)
|
Forge Welded Copper Tube Types WK, WL and WM
|
All building classifications
|
B-447-80
|
ASTM; NSF
|
(1b)
|
Galvanized Steel Pipe
|
All building classifications
|
B-125.2-72; A-120-82
|
ASTM; NSF
|
(1a)
|
Polybutylene (PB) Plastic Tubing
|
One to Four Family Structures — Hot &
Cold
|
D-3309-81b; NSF No. 14
|
ASTM; NSF
|
(2)
|
CPVC Pipe, Fittings and Cement
|
All building classifications Hot and Cold
|
D-2846-82 NSF No. 14
|
ASTM NSF
|
(3)
|
Re-Tube Cross-Linked Polyethylene Tubing
|
One to Four Family Structures — Hot &
Cold
|
NSF No. 14
|
NSF
|
(2)
|
NOTES:
| |||
---|---|---|---|
1.
|
a.
|
Flexible Couplings and Fittings as per § 860-93 may be used in lieu of screwed joints and screwed fittings on Schedule 40, Steel Pipe for water distribution systems. All Pipe, fittings, and flexible type couplings shall be galvanized.
| |
b.
|
Solders and fluxes used for the installation
or repair of potable water supply systems shall not contain more than
0.2% lead.
| ||
2.
|
a.
|
Installation shall be in accordance with Manufacturers
recommendations and Code Requirements.
| |
b.
|
(PB) Tubing limited to one to four family structures-New-Remodeling-Rehab.
| ||
c.
|
Tubing shall conform to applicable ASTM and
NSF Standards and be so marked.
| ||
d.
|
Maximum hot water temperature not to exceed
180° F.
| ||
e.
|
Water Distribution Pressure not to exceed 80 P.S.I. (§ 860-177B).
| ||
f.
|
Tubing to be run straight, in uniform alignment,
utilize proper fittings for change of direction and be supported every
three feet for all sizes in this specification with smooth plastic
or plastic coated non-binding hangers to allow for expansion and contraction
and eliminate noise transmission. Tubing shall not be rigidly anchored.
| ||
g.
|
Joints or connections will not be permitted
underground or under concrete floor slabs.
| ||
h.
|
Approved joints and connections utilizing barbed
brass fittings and aluminum compression bands crimped with approved
tools or celcon fittings and nuts with approved flared connections.
| ||
i.
|
Proper adapter or transition fittings to be
used for connections to equipment, or other approved piping material.
Only listed teflon thread tape or plastic thread lubricant shall be
used for threaded connections. Conventional pipe thread compounds,
putty, linseed oil base products and unknown mixtures shall not be
used.
| ||
j.
|
Piping to be sized according to code requirements.
| ||
k.
|
Connection to water heaters: PB Tubing may be
directly connected to a storage type water heater provided a minimum
of six inches is maintained between the flue of gas fired water heater
and the PB Tubing. However, it is recommended that a minimum six inches
of metal pipe be installed between the hot water outlet and the PB
system. On instantaneous type heaters, an 18-inch minimum of approved
metal pipe is required.
| ||
l.
|
A properly executed warranty against defective
material or workmanship be furnished to the homeowner by the system
manufacturer.
| ||
3.
|
CPVC Installation Requirements.
| ||
a.
|
Installation shall be in accordance with Manufacturers
recommendations applicable Standards and Code Requirements.
| ||
b.
|
Identification — The pipe, fittings and
solvent cements shall be marked in accordance with ASTM D —
2846 and with the NSF symbol.
| ||
c.
|
Maximum hot water temperature not to exceed
180° F.
| ||
d.
|
Water distribution pressure not to exceed 80 P.S.I. (§ 860-177B).
| ||
e.
|
Pipe to be run straight, in uniform alignment,
utilize proper fittings for change of direction and be supported every
three feet for all sizes in this specification with smooth plastic
or plastic coated non-binding hangers to allow for expansion and eliminate
noise transmission.
| ||
f.
|
Thermal Expansion — The linear thermal
expansion rate for CPVC is approximately 1/2 in /10° F. temperature
change for each 100 ft. of pipe or tubing. Installation of long runs
of pipe require 1/16 to 3/32 in. longitudinal clearance per foot of
run to accommodate thermal expansion. Proper design installation requires
offsets of 12 in. or more for every straight 10 ft. run of pope to
absorb thermal movement. Pipe should not be anchored rigidly to a
support but rather be secured with broad, smooth hangers providing
for a degree of movement.
| ||
g.
|
Piping to be sized and pressure tested according
to Code Requirements.
| ||
h.
|
Water Heaters — pipe and fittings covered
by this installation requirement are not intended for use at temperatures
above 180° F. CPVC Pipe may be directly connected to a storage
type water heater provided a minimum of six in. is maintained between
the flue of gas fired water heaters and the CPVC pipe. However, it
is recommended that a minimum six in. of metal pipe be installed between
the hot water outlet and the CPVC system. Instantaneous type water
heaters — CPVC system's may not be suitable for use on this
type heater. Approval of pipe manufacturer and his design requirements
are required if system is to be used with instantaneous heater.
| ||
i.
|
Approved adapter or transition fittings to be
used for connections to equipment or other approved piping material.
| ||
j.
|
Step-by-step Assembly — Correct assembly
requires the following:
| ||
1.
|
Cut the pipe square;
| ||
2.
|
Remove burrs;
| ||
3.
|
Check for interference fit;
| ||
4.
|
Clean both pipe and fittings with a recommended
CPVC cleaner or by light sanding or both;
| ||
5.
|
Apply a liberal coat of CPVC solvent cement
to the pipe and a light coat of cement to the fitting;
| ||
6.
|
Assemble immediately by bottoming the pipe in
the fitting socket and rotating a quarter turn as the joint is assembled;
and
| ||
7.
|
Remove excess cement from the joint.
| ||
k.
|
Caution: Joints mistakenly made with only a
cleaning solvent may pass the usual cold water pressure check, but
can be expected to fail later in hot water service. As a result pressure
tests will require the hot water tank to be activated and normal working
temperatures attained during test.
| ||
6.
|
Schedule 40, NSF Seal required, solvent cement
shall meet the latest applicable standards for use on PVC/ABS and
the co-mingling of PVC and ABS is prohibited. The pipe shall be protected
from fastener penetration where pipe passes through partitions by
the use of 16-gauge steel plates or equal protection. Installations
shall be in accordance with manufacturers recommendations or installation
standards covering material. Approved expansion joints at three story
intervals or as recommended by manufacturer will be required for high-rise
construction.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe & Fittings Extra Heavy
& Service Weight
|
All building classifications
|
A-112.5.1-73; A-74-82
|
ANSI; ASTM
|
(1)
|
Hubless Cast Iron Soil Pipe & Fittings
|
All building classifications
|
301-82
|
CISPI
|
(2)
|
Brass Pipe S.P.S.
|
All building classifications
|
H-27-1-67; B-43-80
|
ANSI; ASTM
|
(3)
|
Copper Pipe S.P.S.
|
All building classifications
|
H-26.1-67; B-42-83
|
ANSI; ASTM
|
(3)
|
Copper Tube Types K, L, M & DWV
|
All building classifications
|
H-23.1-70; B-306-81
|
ANSI; ASTM
|
(4)
|
Galvanized Steel Pipe
|
All building classifications
|
B-125.2-70; A-120-82
|
ANSI; ASTM
|
(5)
|
Polyvinyl Chlorine PVC Schedule 40
|
All building classifications
|
NSF-DWV; D-2665-82
|
NSF; ASTM
|
(6)
|
ABS Schedule 40 Foam Core
|
All building classifications
|
F-628-81
|
ASTM;
|
(6)
|
Acrylonitrile Butadiene Styrene (ABS) Schedule
40
|
All building classifications
|
NSF-DWV; D-2661-81
|
NSF; ASTM
|
(6)
|
PVC Schedule 40 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(6)
|
COEX ABS DWV
|
All building classifications
|
D-2661-81
|
ASTM
|
(6)
|
NOTES:
| |
---|---|
1.
|
Caulked or gasket joints meeting ASTM Standard
C-564-82.
|
2.
|
As approved in § 860-68A.
|
3.
|
Utilizing cast iron screwed drainage fittings.
|
4.
|
Where urinals are to be installed on a copper
or copper alloy type DWV system, including all copper DWV materials,
the Administrative Authority will require acceptable design criteria
such as, but not limited to, automatic flushing units (Ultraflow)
— an electric push button controlled water distribution system
to be installed in accordance with manufacturers recommendations and
code requirements, to prevent the degradation of copper or copper
allow DWV by the action of urine.
|
5.
|
Minimum size 2 1/2 inches.
|
6.
|
Schedule 40, NSF Seal required, solvent cement
shall meet the latest applicable standards for use on PVC/ABS and
the co-mingling of PVC and ABS is prohibited. The pipe shall be protected
from fastener penetration where pipe passes through partitions by
the use of 16-gauge steel plates or equal protection. Installations
shall be in accordance with manufacturers recommendations or installation
standards covering material. Approved expansion joints at three story
intervals or as recommended by manufacturer will be required for high-rise
construction.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe & Fittings Extra Heavy
& Service Weight
|
All building classifications
|
A-112.5.1-73; A-74-82
|
ANSI; ASTM
|
(1)
|
Hubless Cast Iron Soil Pipe & Fittings
|
All building classifications
|
301-82
|
CISPI
|
(2)
|
Polyvinyl Chloride PVC Schedule 40
|
All building classifications
|
NSF-DWV; D-2665-82
|
NSF; ASTM
|
(3)
|
ABS Schedule 40 Foam Core
|
All building classifications
|
F-628-813
|
ASTM
|
(3)
|
Acrylonitrile Butadiene Styrene ABS Schedule
40
|
All building classifications
|
NSF (DWV); D-2661-81
|
NSF; ASTM
|
(3)
|
Clay Pipe Extra Strength
|
One to Four Family Structures
|
C-700-83
|
ASTM
|
(4)
|
PVC Schedule 40 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(6)
|
COEX ABS DWV
|
All building classifications
|
D-2661-81
|
ASTM
|
(6)
|
NOTES:
| ||
---|---|---|
1.
|
Caulked or gasket joints meeting ASTM Standards
C564-82.
| |
2.
|
As approved in Section § 860-68A..
| |
3.
|
Schedule 40, NSF seal is required, solvent cement
shall meet the latest applicable standards for use on PVC/ABS and
the co-mingling of PVC and ABS is prohibited. Installation shall be
in accordance with manufacturers recommendations or installation standards
covering material.
| |
4.
|
Vitrified clay sewer pipe for underground building
drains in one to four family structures may be used subject to the
following installation requirements:
| |
a.
|
Pipe shall be extra strength with premium joints.
| |
b.
|
Cut sections of pipe shall have oakum and poured
— bitumastic joints or approved preformed factory joints.
| |
c.
|
Tops of hubs or fittings shall finish flush
or below basement floors where change in pipe material will occur.
| |
d.
|
Requirement of a cleanout at end of main runs,
where main is not an extension of stack. Additional cleanouts along
main run spaced not more than 50 feet apart.
| |
e.
|
Pipe shall be laid on a four inch bed of compacted
slag, sand or equivalent granular material, and an envelope of the
same material at sides and top of pipe. Slag shall be high lime basic
reaction. Minimum thickness of encasement shall be six inches on each
side of pipe, minimum of four inches from top of pipe to underside
of slab, and 12 inches above top of pipe elsewhere. Installations
shall be in accordance with ASTM C-12 Specifications.
| |
f.
|
All vitreous clay ells shall be long radius
type to permit four inches granular cover over top of pipe under floor
slab.
| |
g.
|
Concrete encasement of 3,000 lbs. compressive
strength four inch thick, around and under all vitreous clay traps
and ells as protection against breakage due to settlement or cleanout
operation by rodding.
| |
h.
|
Soil and waste stacks above ground shall be
adequately supported so that no weight load is imposed on the building
drainage system.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe & Fittings Extra Heavy
& Service Weight
|
All building classifications
|
A-112.5.1-73; A-74-82
|
ANSI; ASTM
|
(1)
|
Hubless Cast Iron Soil Pipe & Fittings
|
All building classifications
|
301-82
|
CISPI
|
(2)
|
PVC Schedule 40
|
All building classifications
|
NSF-DWV; D-2665-82
|
NSF; ASTM
|
(3)
|
ABS Schedule 40
|
All building classifications
|
NSF (DWV); D-2661-81
|
NSF; ASTM
|
(3)
|
ABS Schedule 40 Foam Core
|
All building classifications
|
F-628-81
|
NSF; ASTM
|
(3)
|
Clay Pipe Extra Strength
|
One to Four Family Structures
|
C-700-83
|
ASTM
|
(4)
|
PVC Schedule 40 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(3)
|
COEX ABS DWV
|
All building classifications
|
D-2661-81
|
ASTM
|
(3)
|
NOTES:
| ||
---|---|---|
1.
|
Caulked or gasket joints meeting ASTM Standards
C564-82.
| |
2.
|
As approved in Section § 860-68A.
| |
3.
|
Schedule 40, NSF seal is required, solvent cement
shall meet the latest applicable standards for use on PVC/ABS and
the co-mingling of PVC and ABS is prohibited. Installation shall be
in accordance with manufacturers recommendations or installation standards
covering material.
| |
4.
|
Vitrified clay sewer pipe for underground building
drains in one to four family structures may be used subject to the
following installation requirements:
| |
a.
|
Pipe shall be extra strength with premium joints.
| |
b.
|
Cut sections of pipe shall have oakum and poured
— bitumastic joints or approved preformed factory joints.
| |
c.
|
Tops of hubs or fittings shall finish flush
or below basement floors where change in pipe material will occur.
| |
d.
|
Requirement of a cleanout at end of main runs,
where main is not an extension of stack. Additional cleanouts along
main run spaced not more than 50 feet apart.
| |
e.
|
Pipe shall be laid on a four inch bed of compacted
slag, sand or equivalent granular material, and an envelope of the
same material at sides and top of pipe. Slag shall be high lime basic
reaction. Minimum thickness of encasement shall be six inches on each
side of pipe, minimum of four inches from top of pipe to underside
of slab, and 12 inches above top of pipe elsewhere. Installations
shall be in accordance with ASTM C-12 Specifications.
| |
f.
|
All vitreous clay ells shall be long radius
type to permit four inches granular cover over top of pipe under floor
slab.
| |
g.
|
Concrete encasement of 3,000 lbs. compressive
strength four inch thick, around and under all vitreous clay traps
and ells as protection against breakage due to settlement or cleanout
operation by rodding.
| |
h.
|
Soil and waste stacks above ground shall be
adequately supported so that no weight load is imposed on the building
drainage system.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe & Fitting Extra Heavy
& Service Weight
|
All building classifications
|
A-112.5.1-73; A-74-82
|
ANSI; ASTM
|
(1)
|
Hubless Cast Iron Soil Pipe & Fittings
|
All building classifications
|
301-82
|
CISPI
|
(2)
|
Clay Sewer Pipe Extra Strength
|
All building classifications
|
C-700-83
|
ASTM
|
(3)
|
Polyvinyl Chloride PVC Schedule 40
|
All building classifications
|
NSF-DWV; D-2665-82
|
NSF; ASTM
|
(4)
|
Polyvinyl Chloride PVC Sewer Pipe & Fittings
|
All building classifications
|
D-3033-83; D-2729-83; D-3034-83
|
ASTM; ASTM
|
(4), (4a), (4b)
|
PVC — Z46
|
All building classifications
|
F-789-82
|
ASTM
|
(4), (4b)
|
PVC — A2000
|
All building classifications
|
F-949
|
ASTM
|
(4)
|
PVC Schedule 40 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(4)
|
PVC PS 50 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(4)
|
PVC PS 100 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(4)
|
COEX ABS DWV
|
All building classifications
|
D-2661-81
|
ASTM
|
(4)
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
Acrylonitrile Butadiene Styrene ABS Schedule
40
|
All building classifications
|
NSF (DWV); D-661-81
|
NSF; ASTM
|
(4)
|
ABS Composite Sewer Pipe
|
All building classifications
|
D-2680-70
|
ASTM
|
(5), (4a)
|
Acrylonitrile Butadiene Styrene ABS Sewer Pipe
& Fittings
|
All building classifications
|
D-2751-83a
|
ASTM
|
(4), (4a)
|
ABS Schedule 40 Foam Core
|
All building classifications
|
F-628-81
|
ASTM
|
(4)
|
Asbestos Cement Sewer Pipe
|
All building classifications
|
C-428-81
|
ASTM
|
(6), (4a)
|
Bituminized Sewer Pipe
|
One to Four Family Structures
|
D-1861-81
|
ASTM
|
(7), (4a)
|
Concrete Sewer Pipe
|
One to Four Family Structures
|
C-14-82
|
ASTM
|
(8), (4a)
|
NOTES:
| ||
---|---|---|
1.
|
Caulked or gasket joints meeting ASTM Standards
C564-82.
| |
2.
|
As approved in Section § 860-68A.
| |
3.
|
Premium joints conforming with ASTM-C-425-82.
Material shall not be run or laid in same trench as the water service
pipe.
| |
4.
|
Install in accordance with installations standard
covering underground installation of flexible thermoplastic sewer
pipe.
| |
Schedule 40, NSF seal required, solvent cement
shall meet the latest applicable standards for use on PVC/ABS and
the co-mingling of PVC and ABS is prohibited. Installations shall
be in accordance with manufacturers recommendations of installation
standards covering material.
| ||
4a.
|
Non-pressure systems.
| |
4b.
|
Polyvinyl chloride (PVC) sewer pipe fittings
with elastomeric seal joints shall comply with ASTM D3212-81.
| |
5.
|
Joints and factory fabricated fittings conforming
to ASTM designation D 2680-70.
| |
6.
|
Pipe, fittings and adaptors shall be joined
by gaskets meeting the requirements of ASTM D 1878.
| |
7.
|
Limited to one to four family structures —
Installations shall be in accordance with all applicable standards
covering installation procedures. Pipe and fittings to be joined with
accurately machined or tapered joints.
| |
8.
|
Limited one to four family structures. Installation
shall be in accordance with all applicable standards covering installation
procedure. Joining methods shall meet applicable standards.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron
|
All building classifications
|
None Available
| ||
Reinforced Concrete
|
All building classifications
|
None Available
|
(1)
| |
Fiberglass
|
All building classifications
|
None Available
|
(2)
| |
Structural Foam SF 30
|
All building classifications
|
PS-15-69
|
(3)
|
NOTES:
| ||||
---|---|---|---|---|
1.
|
Requires Bituminized Coating.
| |||
2.
|
Fiberglass basins approved by Allegheny County
Health Department Plumbing Board.
| |||
3.
|
As approved by Allegheny County Plumbing Board.
| |||
List of fiberglass basins currently Approved
include:
| ||||
1.
|
Fiberbasins Inc.
|
All Building Classifications
| ||
2.
|
A.K. Plastics Co.
|
All Building Classifications
| ||
3.
|
Jackel-Fiberglass
|
All Building Classifications
| ||
4.
|
Structural Foam SF-30
|
All Building Classifications
| ||
5.
|
Ashland-Plastics
|
Residential
| ||
6.
|
Gerish Fiberglass
|
All Building Classifications
| ||
7.
|
Environmental One Fiberglass Basin
|
All Building Classifications
| ||
8.
|
Liberty Pump #403
|
All Building Classifications
| ||
9.
|
HICO 1300 Super Polyethylene
|
Residential
| ||
10.
|
WRS-5-6 Drainosaur JR.
|
All Building Classification
| ||
11.
|
Liberty Simplex 700 Series
|
All Building Classification
| ||
12.
|
Liberty Duplex 1100 Series
|
All Building Classification
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe & Fitting Extra Heavy
& Service Weight
|
All building classifications
|
A-112.5.1-73; A-74-82
|
ANSI; ASTM
|
(1)
|
Hubless Cast Iron Soil Pipe & Fittings
|
All building classifications
|
301-82
|
CISPI
|
(2)
|
Brass Pipe S.P.S.
|
All building classifications
|
H-27-1-67; B-43-80
|
ANSI; ASTM
|
(3)
|
Copper Pipe S.P.S.
|
All building classifications
|
H-26.1-67; B-42-83
|
ANSI; ASTM
|
(3)
|
Copper Tube Types K, L, M & DWV
|
All building classifications
|
H-23.1-70; B-306-81
|
ANSI; ASTM
|
(4)
|
Galvanized Steel Pipe
|
All building classifications
|
B-125.2-70; A-120-82
|
ANSI; ASTM
|
(5)
|
Polyvinyl Chlorine PVC Schedule 40
|
All building classifications
|
D-2665-82; NSF
|
ASTM; ANSI; NSF
|
(6)
|
PVC Schedule 40 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(6)
|
COEX ABD DWV
|
All building classifications
|
D-2661-81
|
ASTM
|
(6)
|
Acrylonitrile Butadiene Styrene (ABS) Schedule
40
|
All building classifications
|
NSF-DWV; D-2661-81
|
ASTM; ANSI; NSF
|
(6)
|
ABS Schedule 40 Foam Core
|
All building classifications
|
F-628-81
|
ASTM
|
(6)
|
NOTES:
| |
---|---|
1.
|
Caulked or gasket joints meeting ASTM Standard
C-564-82.
|
2.
|
As approved in § 860-68A.
|
3.
|
Utilizing cast iron screwed drainage fittings.
|
4.
|
Utilizing copper DWV solder joint fittings
|
5.
|
Utilizing galvanized malleable iron screwed
fittings.
|
6.
|
Schedule 40, NSF Seal required, solvent cement
shall meet the latest applicable standards for use on PVC/ABS and
the co-mingling of PVC and ABS is prohibited. The pipe shall be protected
from nail penetration where pipe passes through wood partitions by
the use of 16-gauge steel plates or equal protection. Installations
shall be in accordance with manufacturers recommendations or installation
standards covering material. Approved expansion joints at three story
intervals or as recommended by manufacturer will be required for high
rise construction.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe & Fittings Extra Heavy
& Service Weight
|
All building classifications
|
A-112.5.1-73
|
ANSI; ASTM
|
(1)
|
Hubless Cast Iron Soil Pipe & Fittings
|
All building classifications
|
301-82
|
CISPI
|
(2)
|
PVC Schedule 40
|
All building classifications
|
NSF-DWV; D2665-82
|
NSF; ASTM
|
(3)
|
ABS Schedule 40
|
All building classifications
|
NSF-DWV; D-2661-82
|
NSF; ASTM
|
(3)
|
ABS Schedule 40 Foam Core
|
All building classifications
|
F-628-81
|
ASTM
|
(3)
|
Clay Pipe Extra Strength
|
One to Four Family Structures
|
C-700-83
|
ASTM
|
(4)
|
PVC Schedule 40 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(3)
|
COEX ABS DWV
|
All building classifications
|
D-2661-81
|
ASTM
|
(3)
|
NOTES:
| ||
---|---|---|
1.
|
Caulked or gasket joints meeting ASTM Standards
C564-82.
| |
2.
|
As approved in § 860-68A.
| |
3.
|
Schedule 40, NSF seal required, solvent cement
shall meet the latest applicable standards for use on PVC/ABS and
the co-mingling of PVC and ABS is prohibited. Installation shall be
in accordance with manufacturers recommendations or installation standards
covering material.
| |
4.
|
Vitrified clay sewer pipe for underground building
drains in one to four family structures may be used subject to the
following installation requirements:
| |
a.
|
Pipe shall be extra strength with premium joints.
| |
b.
|
Cut sections of pipe shall have oakum and poured
— bitumastic joints or approved preformed factory joints.
| |
c.
|
Tops of hubs or fittings shall finish flush
or below basement floors where change in pipe material will occur.
| |
d.
|
Requirement of a cleanout at end of main runs,
where main is not an extension of stack. Additional cleanouts along
main run spaced not more than 50 feet apart.
| |
e.
|
Pipe shall be laid on a four inch bed of compacted
slag, sand or equivalent granular material, and an envelope of the
same material at sides and top of pipe. Slag shall be high lime basic
reaction. Minimum thickness of encasement shall be six inches on each
side of pipe, minimum of four inches from top of pipe to underside
of slab, and 12 inches above top of pipe elsewhere. Installations
shall be in accordance with ASTM C-12 Specifications.
| |
f.
|
All vitreous clay ells shall be long radius
type to permit four inches granular cover over top of pipe under floor
slab.
| |
g.
|
Concrete encasement of 3,000 lbs. compressive
strength four inch thick, around and under all vitreous clay traps
and ells as protection against breakage due to settlement or cleanout
operation by rodding.
| |
h.
|
Soil and waste stacks above ground shall be
adequately supported so that no weight load is imposed on the building
drainage system.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe & Fitting Extra Heavy
& Service Weight
|
All building classifications
|
A-112.5.1-73; A-74-82
|
ANSI; ASTM
|
(1)
|
Hubless Cast Iron Soil Pipe & Fittings
|
All building classifications
|
301-82
|
CISPI
|
(2)
|
Brass Pipe S.P.S.
|
All building classifications
|
H-27-1-67; B-43-80
|
ANSI; ASTM
|
(3)
|
Copper Pipe S.P.S.
|
All building classifications
|
H-26.1-67; B-42-83
|
ANSI; ASTM
|
(3)
|
Copper Tube Types K, L, M & DWV
|
All building classifications
|
H-23.1-70; B-306-81
|
ANSI; ASTM
|
(4)
|
PVC Schedule 40
|
All building classifications
|
NSF-DWV D-2665-82
|
NSF; ASTM
|
(4)
|
ABS Schedule 40
|
All building classifications
|
NSF-DWV; D-2661-81
|
NSF; ASTM
|
(4)
|
ABS Schedule 40 Foam Core
|
All building classifications
|
FNSF-DWV
|
NSF
|
(4)
|
Galvanized Steel Pipe
|
All building classifications
|
B-125.2-70; A-120-82
|
ANSI; ASTM
|
(5)
|
PVC Schedule 40 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(4)
|
COEX ABS DWV
|
All building classifications
|
D-2661-81
|
ASTM
|
(4)
|
NOTES:
| |
---|---|
1.
|
Caulked or gasket joints meeting ASTM Standard
C-564-82.
|
2.
|
As approved in § 860-68A.
|
3.
|
Utilizing cast iron screwed drainage fittings.
|
4.
|
Schedule 40, NSF Seal required, solvent cement
shall meet the latest applicable standards for use on PVC/ABS and
the co-mingling of PVC and ABS is prohibited. The pipe shall be protected
from nail penetration where pipe passes through wood partitions by
the use of 16-gauge steel plates or equal protection. Installations
shall be in accordance with manufacturers recommendations or installation
standards covering material. Approved expansion joints at three story
intervals or as recommended by manufacturer will be required for high
rise construction.
|
5.
|
Minimum size 2 1/2 inches.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe & Fittings Extra Heavy
& Service Weight
|
All building classifications
|
A-112.5.1-73; A-74-82
|
ANSI; ASTM
|
(1)
|
Hubless Cast Iron Soil Pipe & Fittings
|
All building classifications
|
301-82
|
CISPI
|
(2)
|
PVC Schedule 40
|
All building classifications
|
NSF-DWV; D-2665-82
|
NSF; ASTM
|
(3)
|
ABS Schedule 40
|
All building classifications
|
NSF (DWV); D-2661-81
|
ASTM
|
(3)
|
ABS Schedule 40 Foam Core
|
All building classifications
|
F-628-813
|
NSF; ASTM
|
(3)
|
Clay Pipe Extra Strength
|
One to Four Family Structures
|
C-700-83
|
ASTM
|
(4)
|
PVC Schedule 40 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(4)
|
COEX ABS DWV
|
All building classifications
|
D-2661-81
|
ASTM
|
(4)
|
NOTES:
| |
---|---|
1.
|
Caulked or gasket joints meeting ASTM Standards
C564-82.
|
2.
|
As approved in § 860-68A.
|
3.
|
Schedule 40, NSF seal is required, solvent cement
shall meet the latest applicable standards for use on PVC/ABS and
the co-mingling of PVC and ABS is prohibited. Installation shall be
in accordance with manufacturers recommendations or installation standards
covering material.
|
4.
|
Limited one to four family structures —
same bedding and concrete encasement requirements as required for
building sanitary drains.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe & Fitting Extra Heavy
& Service Weight
|
All building classifications
|
A-112.5.1-73; A-74-82
|
ANSI; ASTM
|
(1)
|
Hubless Cast Iron Soil Pipe & Fittings
|
All building classifications
|
301-82
|
CISPI
|
(2)
|
PVC Schedule 40
|
All building classifications
|
NSF-DWV; D-2665-82
|
NSF; ASTM
|
(4)
|
ABS Schedule 40
|
All building classifications
|
NSF-DWV; D-2661-81
|
NSF; ASTM
|
(4)
|
ABS Schedule 40 Foam Core
|
All building classifications
|
F-628-81
|
ASTM
|
(4)
|
Clay Sewer Pipe Extra Length
|
Limited one to four family structure
|
C-700-83
|
ASTM
|
(3), (4a)
|
PVC — Z 46
|
All building classifications
|
F-789-82
|
ASTM
|
(4), (4b)
|
PVC — A2000
|
All building classifications
|
F-949
|
ASTM
|
(4), (4b)
|
Polyvinyl Chloride
|
All Bldg..
|
D-3033
|
ASTM
|
(4)
|
PVC Sewer Pipe & Fitting
|
Classifications
|
D-3034; D-2729
|
ASTM; ASTM
|
(4a), (4b)
|
ABS Composite Sewer Pipe
|
All building classifications
|
D-2680-76
|
ASTM
|
(4), (4b), (7)
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
Acrylonitrile Butadiene Styrene ABS Sewer Pipe
& Fitting
|
All building classifications
|
D-2751-83a
|
ASTM
|
(4), (4b), (4a)
|
Reinforced Concrete Sewer Pipe
|
All building classifications
|
C-76-83
|
ASTM
|
(4a)
|
Asbestos Cement Sewer Pipe
|
All building classifications
|
C-644-71
|
ASTM
|
(6)
|
Corrugated Galvanized Steel Sewer Pipe
|
All building classifications
|
A-444-71
|
ASTM
|
(8), (4a)
|
Aluminized Corrugated Steel
|
All building classifications
|
M-274-79
|
AASHTO
|
(4a) Only
|
Bituminized Sewer Pipe
|
Limited One to Four Family Structure
|
D-1861-81
|
(4a), (9)
| |
Non-reinforced Concrete Sewer Pipe
|
Limited One to Four Family Structure
|
C-14-82
|
ASTM
|
(5), (4a)
|
Modified Styrene Rubber SR Sewer Pipe
|
D-2852-74
|
ASTM
|
(10), (4a)
| |
Corrugated Polyethylene Drainage Tubing
|
Light Weight Heavy Weight
|
F-405-76b; M-294-831; M-252-811
|
ASTM; AASHTO; AASHTO
|
(10), (4a), (11)
|
Polyethylene Smooth Wall
|
D-3350
|
ASTM
|
(4a), (10)
| |
PVC Schedule 40 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(4)
|
PVC PS 50 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(4)
|
PVC PS 100 Foam Core
|
All building classifications
|
F-891
|
ASTM
|
(4)
|
COEX ABS DWV
|
All building classifications
|
D-2661-81
|
ASTM
|
(4)
|
NOTES:
| ||
---|---|---|
1.
|
Caulked or gasket joints meeting ASTM Standards
C-564-82.
| |
2.
|
As approved in § 860-68A.
| |
3.
|
Premium joints conforming with ASTM C-425-82.
| |
4.
|
Install in accordance with installations standard
covering underground installation of flexible thermoplastic sewer
pipe.
| |
Schedule 40, NSF seal required, solvent cement
shall meet the latest applicable standards for use on PVC/ABS and
the co-mingling of PVC and ABS is prohibited. Installation shall be
in accordance with manufacturers recommendations or installation standards
covering material.
| ||
4a.
|
Non pressure systems.
| |
4b.
|
Joints and fittings using elastomeric seals
shall conform to ASTM 3212-76.
| |
5.
|
Concrete sewer pipe and fittings shall be joined
by means of flexible rubber sealing rings compressed to provide water-tight
joints conforming to ASTM C443, or by listed one-piece molded rubber
couplings. Cement joints are not permitted except for repairs or connections
to existing lines constructed with such joints.
| |
6.
|
Pipe, fittings and adaptors shall be joined
by gaskets meeting the requirements of ASTM D 1869-78.
| |
7.
|
Joints and factory fabricated fittings conforming
to ASTM designation D 2680-76.
| |
8.
|
Bituminized coating required, except where soils
engineering report supports the use of plain galvanized pipe.
| |
9.
|
Limited to one to four family structures. Installations
shall be in accordance with all applicable standards covering installation
procedures. Pipe and fittings to be joined with accurately machined
or tapered joints.
| |
10.
|
Limited to building storm sewers receiving water
from down spouts or conductors not connected to a combination or storm
sewer system but terminating in a street gutter, leaching pit or other
acceptable point of disposal. Material not to be used within five
feet of building or to be over two feet installed depth.
| |
11.
|
Limited to building storm sewers receiving water
from down spouts or conductor not connected to a combination sewer
system. Material not be used with five feet of building.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe
|
All building classifications
|
A-74-82
|
ASTM
|
(1)
|
Clay Sewer Pipe
|
All building classifications
|
C-4-81; C-700-83
|
ASTM
|
(1)
|
Asbestos Cement
|
All building classifications
|
C-508-83
|
ASTM
|
(1)
|
Concrete
|
All building classifications
|
C-14-82; C-76-83
|
ASTM
|
(1)
|
Bituminized Fiber
|
All building classifications
|
D-2311-81
|
ASTM
|
(1)
|
Bituminized Corrugated Steel
|
All building classifications
|
A-444-71
|
ASTM
|
(1)
|
PVC Sewer Pipe
|
All building classifications
|
D-2729-83
|
ASTM
|
(1)
|
Modified Styrene (SR) Plastic
|
All building classifications
|
D-3928-81
|
ASTM
|
(1)
|
Corrugated Polyethylene Drainage Tube Perforated
Form
|
All building classifications
|
F-405-76b
|
ASTM
|
(1)
|
Perforated Polyethylene
|
All building classifications
|
3350-74; M-294-831; M-252-811
|
ASTM
|
(1)
|
Polyethylene Smooth Wall
|
D-3350
|
ASTM
|
(1)
|
NOTES:
| |
---|---|
1.
|
See § 860-167 for foundation drain installation requirements.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Cast Iron Soil Pipe
|
All building classifications
| |||
Concrete — Reinforced
|
All building classifications
| |||
Clay Tile
|
All building classifications
| |||
Masonry
|
All building classifications
| |||
Plastic
|
(1)
| |||
Fiberglass
|
(1)
| |||
Structural Foam SF 30
|
All building classifications
|
(1)
|
NOTES:
| |||
---|---|---|---|
1.
|
Fiberglass and plastic receptors approved by
ACPB:
| ||
1.
|
Fiberglass Basins by Jackel
|
All Building Classifications
| |
2.
|
Fiberglass Basins by Fiberbasin, Inc.
|
All Building Classifications
| |
3.
|
Fiber Basins by A.K.
|
All Building Classifications
| |
4.
|
Polycrock Basins by Genova
|
All Building Classifications
| |
5.
|
Ashland-Plastics
|
Limited One to Four Family Structures
| |
6.
|
Gerish Fiberglass
|
All Building Classifications
| |
7.
|
Jackel SF 22 Structural Foam
|
All Building Classifications
|
Cast Iron
| |
Copper
| |
Lead
| |
Aluminum
| |
Plastic — As approved by ACPB
| |
Johns-Manville — Flex-I-drain
| |
Specialty Products — (RD, RDS, RBD, PBDS,
RASD)
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
| |
---|---|---|---|---|---|
High Silicon Content Cast Iron Pipe
|
All building classifications
|
(CW) Corrosion Waste
|
(1)
| ||
Borosilicate Glass Pipe
|
All building classifications
|
(CW) C-599-70
|
ASTM
|
(2)
| |
Lead Pipe
|
All building classifications
|
(CW)
|
(3)
| ||
Vulcathene — Polypropylene & Polyethylene
Pipe & Fittings; Joints of Heat Fusion or Vultite Compression
Fittings
|
All building classifications
|
Type I D-1248; Type II D-2146
|
ASTM
|
(5)
| |
Fuseal — Polypropylene Pipe & Fittings
— Sch. 40 Joints — Heat Fusion
|
All building classifications
|
NSF (CW); Type I — 29209, D-2146
|
NSF; ASTM
|
(5)
| |
Orion Fittings, Inc.
| |||||
1.
|
Polyprolene & Polyethylene Pipe & Fittings
— Sch. 40, Heat Fusion Joints
|
All building classifications
|
Type II — 2306, D-2146; D-1248
|
ASTM
|
(5)
|
2.
|
Polypropylene Pipe & Fittings — Sch.
40, Type II — Heat Fusion Joints or "Riontite" Mechanical MJ
Coupler System
|
All building classifications
|
D-2146
|
ASTM
|
(5)
|
3.
|
Fire Retardant — Polypropylene Pipe &
Fittings — Sch. 40, Type II — Heat Fusion Joints or "Riontite"
Mechanical MJ Coupler System
|
All building classifications
|
D-2146 (with flame resistant additives)
|
ASTM
|
(5)
|
4.
|
Borosilicate Glass Pipe & Polypropylene
Fittings — Joined by the "Riontite" mechanical MJ System
|
All building classifications
|
DD-G-541-B; C-599-70
|
FS; ASTM
|
(5)
|
Modified Epoxy Resin Plastic Pipe with Silica
or Fiber Fillers
|
All building classifications
|
(CW)
|
(4), (5)
|
NOTES:
| |
---|---|
1.
|
Approved Caulked or Mechanical Compression Coupling
Joints.
|
2.
|
Approved Mechanical Compression Coupling Joints.
|
3.
|
Approved Wiped Joints.
|
4.
|
Approved Mechanical Compression Coupling Joints
or Threaded Joints.
|
5.
|
Installation shall be in accordance with manufacturers
recommendation or installation standards covering materials.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
| |
---|---|---|---|---|---|
High Silicon Content Cast Iron Pipe
|
All building classifications
|
(CW) Corrosion Waste
|
(1)
| ||
Borosilicate Glass Pipe
|
All building classifications
|
(CW) C-599-70
|
ASTM
|
(2), (5)
| |
Lead Pipe
|
All building classifications
|
(CW)
|
(3)
| ||
Vulcathene — Polypropylene & Polyethylene
Pipe & Fittings — Joints of Heat Fusion or Vultite Compression
Fittings
|
All building classifications
|
Type I — D-1248; Type II — D-2146
|
ASTM
|
(6)
| |
Fuseal — Polypropylene Pipe & Fittings
— Sch. 40, Joints — Heat Fusion
|
All building classifications
|
NSF; (CW) Type I — 29209, D-2146
|
NSF; ASTM
|
(6)
| |
Orion Fittings, Inc.
| |||||
1.
|
Polyprolene & Polyethylene Pipe & Fittings
— Sch. 40, Heat Fusion Joints
|
All building classifications
|
Type II-2306 D-2146; D-1248
|
ASTM
|
(6)
|
2.
|
Polypropylene Pipe & Fittings — Sch.
40, Type II — Heat Fusion Joints or "Riontite" Mechanical MJ
Coupler System
|
All building classifications
|
D-2146
|
ASTM
|
(6)
|
3.
|
Fire Retardant — Polypropylene Pipe &
Fittings — Sch. 40, Type II — Heat Fusion Joints or "Riontite"
Mechanical MJ Coupler System
|
All building classifications
|
D-2146 (with flame resistant additives)
|
ASTM
|
(6)
|
4.
|
Borosilicate Glass — Pipe & Polypropylene
Fittings — Joined by the "Riontite" mechanical MJ System
|
All building classifications
|
DD-G-541-B; C-599-70
|
FS; ASTM
|
(5)
|
Modified Epoxy Resin Plastic Pipe with Silica
or Fiber Fillers
|
All building classifications
|
(CW)
|
(4)
|
NOTES:
| ||
---|---|---|
1.
|
Approved Caulked or Mechanical Compression Coupling
Joints.
| |
2.
|
Approved Mechanical Compression Coupling Joints.
| |
3.
|
Approved Wiped Joints.
| |
4.
|
Approved Mechanical Compression Coupling Joints
or Threaded Joints.
| |
5.
|
Installation Requirements for Glass Pipe when
Used Underground:
| |
a.
|
All glass pipe shall be coated with at least
1/8" mastic coating including joints. Coating to be administered before
pipe is placed in ditch. After coating pipe is to be laid on a bed
of eight inches of granulated slag, sand, or sandy loam.
| |
b.
|
Piping, after being laid, to be covered by six
inches of granulated slag, sand, or loam and hand filled to a depth
of 12 inches above top of piping. No large boulders or stones to be
placed on pipe at any time.
| |
c.
|
In lieu of protecting glass pipe with a mastic
coating, the Administrative Authority will accept buried glass pipe
when protected by a proper casing, with a thickness capable of supporting
maximum load conditions that can occur in the specific field application
(Example Bury-Pack)
| |
d.
|
It is required that this pipe after being laid,
and tested, shall be inspected by the Administrative Authority and
the inspector be given time to return for a check on the backfill
operation.
| |
6.
|
Installation shall be in accordance with manufacturers
recommendation or installation standards covering materials.
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
| |
---|---|---|---|---|---|
High Silicon Content Cast Iron Pipe
|
All building classifications
|
(CW) Corrosion Waste
|
(1)
| ||
Borosilicate Glass Pipe
|
All building classifications
|
(CW) C-599-70
|
ASTM
|
(2)
| |
Vulcathene — Polypropylene & Polyethylene
Pipe & Fittings — Joints of Heat Fusion or Vultite Compression
Fittings
|
All building classifications
|
Type I — D-1248; Type II — D-2146
|
ASTM
|
(4)
| |
Fuseal — Polypropylene Pipe & Fittings
— Sch. 40, Joints of Heat Fusion
|
All building classifications
|
NSF (CW) Type I- 29209 D-2146
|
NSF ASTM
|
(4)
| |
Orion Fittings, Inc.
| |||||
1.
|
Polyprolene & Polyethylene Pipe & Fittings
— Sch. 40, Heat Fusion Joints
|
All building classifications
|
Type II — 2306 D-2146; D-1248
|
ASTM
|
(4)
|
2.
|
Polypropylene Pipe & Fittings — Sch.
40, Type II — Heat Fusion Joints or "Riontite" Mechanical MJ
Coupler System
|
All building classifications
|
D-2146
|
ASTM
|
(4)
|
3.
|
Fire Retardant — Polypropylene Pipe &
Fittings — Sch. 40, Type II — Heat Fusion Joints or "Riontite"
Mechanical MJ Coupler System
|
All building classifications
|
D-2146 (with flame resistant additives)
|
ASTM
|
(4)
|
4.
|
Borosilicate Glass Pipe & Polypropylene
Fittings — Joined by the "Riontite" mechanical MJ System
|
All building classifications
|
DD-G-541-B; C-599-70
|
FS; ASTM
|
(4)
|
Modified Epoxy Resin Plastic Pipe with Silica
or Fiber Fillers
|
All building classifications
|
(CW)
|
(3)
|
NOTES:
| |
---|---|
1.
|
Approved Caulked or Mechanical Compression Coupling
Joints.
|
2.
|
Approved Mechanical Compression Coupling Joints.
|
3.
|
Approved Mechanical Compression Coupling Joints
or Threaded Joints.
|
4.
|
Installation shall be in accordance with manufacturers
recommendation or installation standards covering materials.
|
Present Approvals
| ||
---|---|---|
No-hub Coupling
|
CISPI
| |
MG Coupling
|
Familian Corp.
| |
No Hub Coupling II
|
U.S., Pipe and Foundry
| |
Band Seal Couplings
|
Mission Clay Products
| |
Husky 4000
|
Anaco
|
Installation of No-hub joints shall be in accordance
with manufacturers recommendations and code requirements.
|
Anaco Uniflex
|
Indiana Seal
| |
Clos-True Inc.
|
Mission Band Seal
| |
D.F.W. Plastic Inc.
|
Murray Quick Seal
| |
Expert
|
PipeConx
| |
Fernco
|
Plumb-Seal
| |
Fernco Model 1059
|
Presently Approved Materials
|
Areas of Permitted Use or Limitations
|
Standards
|
Source
|
Notes
|
---|---|---|---|---|
Drinking Fountains
|
All building classifications
|
1010-8; A112.19.2M-82
|
ARI; ANSI
| |
Drinking Water Coolers Self Contained Mechanically
Refrigerated
|
All building classifications
|
1010-82
|
ARI
| |
Enameled Cast Iron Plumbing Fixtures
|
All building classifications
|
A112.19.1-79
|
ANSI
| |
Earthen Vitreous Glazed Plumbing Fixtures
|
All building classifications
| |||
Formed Metal Porcelain Enameled Sanitary Ware
|
All building classifications
| |||
Glass-Fiber Reinforced Polyester Resin Bathtubs
|
All building classifications
|
Z124.1-80
|
ANSI
| |
Glass-Fiber Reinforced Polyester Resin Shower
Receptors
|
All building classifications
|
Z124.2-80
|
ANSI
| |
Leisure Jetted Whirlpool Bath
|
All building classifications
|
Z-124.1-80
|
ANSI
| |
Premix Molded Stone Shower Receptor
|
All building classifications
|
CS222-59
|
Disregarding the gelcoated feature
| |
Precast Terrazzo Concrete Shower Receptor
|
All building classifications
|
Meeting FHA Specifications for Materials and
Construction
| ||
Porcelain Enameled Tanks for Domestic Use
|
All building classifications
|
CS115-60
|
CS
| |
Staple Vitreous China Plumbing Fixtures
|
All building classifications
|
CS20-63
|
CS
| |
Staple Porcelain Plumbing Fixtures
|
All building classifications
|
CS4-29
|
CS
| |
Stainless Steel Fixtures
|
All building classifications
|
CS243-62
|
CS
| |
Stills, Water; Portable (without heating device)
for U.S.P. Distilled Water
|
All building classifications
|
RR-S-726(1)50
| ||
Vitreous China Plumbing Fixtures PVC Schedule
40
|
All building classifications
|
A112.19.2-73
|
ANSI
|
Plumbing Fixtures Lacking National Standards
But Approved ACPB on Basis of Individual Reports
|
Name of Approved Fixture
|
Manufacturer
|
Description
|
Areas of Permitted Use or Limitations
|
---|---|---|---|
Lav. "Acrylglas"
|
Acryglas Corp.
|
Acrylic Lav.
|
All Buildings
|
Lav. "Aurora"
|
Aurora Manufacturing Co.
|
Synthetic Marble Lav.
|
All Buildings
|
Lav. "Contura"
|
American Standard
|
Melamine Lav.
|
All Buildings
|
Lav. "Glamourtec"
|
Glamour Industrial Products, Inc.
|
Acrylic Lav.
|
All Buildings
|
Lav. Cultured Marble
|
Pacific Fiberglass Manuf. Co.
|
Synthetic Lav.
|
All Buildings
|
Lav. Cultured Marble
|
Mathews Marble Manuf.
|
Synthetic Lav.
|
All Buildings
|
"Ramic" — Tub & Wall Units, Shower
& Wall Units & Lavs.
|
P.F.D. Inc.
|
Acrylic & Fiberglass Tub Wall, Shower &
Lav. Units
|
All Buildings
|
"Neuway" Closet Tank
|
Crane Co.
|
ABS Closet Tank
|
All Buildings
|
"Flushmatic" Closet Tank
|
Water Control Products N.A. Inc.
|
Water Saving Closet Tank
|
All Buildings
|
"Geberit" Closet Tank
|
Geberit Manuf. Co.
|
Water Saving Closet Tank
|
All Buildings
|
"Microphor" Model LF-21- Low Flush Water Closet
|
Microphor, Inc.
|
Water Saving Toilet
|
All Buildings
|
Ultra-One/G
|
Eljer Corporation
|
Water Saving Water Closet Combination
|
All Buildings
|
Water Coolers
|
Oasis
|
Drainless Free Standing
|
All Buildings
|
Ultra Low Flush
|
IFO Cascade
|
Water Saving Water Closet Combination
|
All Buildings
|
Table A — Suds Pressure Relief Vent
| ||
---|---|---|
Waste Size
|
Relief Vent Size
| |
1 1/2
|
2
| |
2
|
2
| |
2 1/2
|
2
| |
3
|
3
| |
4
|
3
| |
5
|
4
| |
6
|
5
| |
8
|
6
|
Table B — Extent of Suds Pressure
Zones for Various Size Soil and Waste Piping
| |||
---|---|---|---|
Extent of Zone (Measure From Fittings)
| |||
Stack Size
|
"U" (Upstream)
|
"D" (Downstream)
| |
1 1/2"
|
5'0"
|
1"6"
| |
2"
|
7'0"
|
1"6"
| |
2 1/2"
|
8'0"
|
2'0"
| |
3
|
10'0"
|
2'6"
| |
4"
|
13'0"
|
3'6"
| |
5"
|
17'0"
|
4'0"
| |
6"
|
20'0"
|
5'0"
|
Standard
|
Source
|
Remarks
| |
---|---|---|---|
Air Gap Standards
|
A40.4
|
ANSI
| |
Pipe — Applied Atmospheric type Anti-Siphon
Devices (Vacuum Breakers)
|
1001-82
|
ASSE
| |
Vacuum Breakers — Anti-Siphon —
Pressure Type
|
1020-82
|
ASSE
| |
Hose Connection Vacuum Breakers
|
1011-82
|
ASSE
| |
Backflow Preventers With Intermediate Atmospheric
Vent
|
1012-78
|
ASSE
| |
Reduced Pressure Principle — Back Pressure
Backflow Preventers
|
1013-80; C506
|
ASSE; AWWA
| |
Double Check Valve Type — Back Pressure
— Back flow Preventers
|
1015-80; C506
|
ASSE; AWWA
| |
Water Closet Flush Tank Ball Cocks
|
1002-79
|
ASSE
| |
Hand (Telephone) Showers
|
1014-79
|
ASSE
| |
Diverters for Plumbing Faucets With Hose Spray
Anti-Siphon Type, Residential Application
|
1025-78
|
ASSE
| |
Wall Hydrant, Frost Proof Automatic Drainage,
Anti-Backflow Types
|
1019-78
|
ASSE
|
Standards
|
Source
|
Notes
| |
---|---|---|---|
Automatic Storage Type Water Heaters with input
less than 50,000 BTU per hour, Approval Requirements for Vol.1
|
Z21.10.1-71
|
ANSI
| |
Circulating Tank, Instantaneous and Automatic
storage type water heaters — Approval Requirements for Vol.
III
|
Z21.10.3-71
|
ANSI
| |
Water Heaters, Side Arm Type
|
Z21.1-2.63
|
ANSI
| |
Draft Hoods, Listing Requirements for
|
A21.12-71
|
ANSI
| |
Electric Water Heaters
|
174-56
|
UL
| |
Home Laundry Equipment, Plumbing Requirements
for
|
A197.2-73 1007-79
|
ANSI ASSE
| |
Household Dishwasher, Plumbing Requirements
for
|
A197.1-73 1006.79
|
ANSI ASSE
| |
Household Food Waste Disposer Units, Plumbing
Requirements for
|
A197.3-73 1008-79
|
ANSI ASSE
| |
Vents, Gas
|
441-64
|
UL
| |
Raypak — Heating and Potable Water System
|
Pipe Sizes
(inches)
|
Inside Diameter
|
Length
(inches)
|
Minimum Weight Each
| |
---|---|---|---|---|
2
|
2 1/4
|
4 1/2
|
1 lb. 0 oz.
| |
3
|
3 1/4
|
4 1/2
|
1 lb. 12 oz.
| |
4
|
4 1/4
|
4 1/2
|
2 lb. 8 oz.
|
Pipe Sizes
(inches)
|
Minimum Weight Each
| |
---|---|---|
1 1/4
|
6 oz.
| |
1 1/2
|
8 oz.
| |
2
|
14 oz.
| |
2 1/2
|
1 lb. 6 oz.
| |
3
|
2 lb. 0 oz.
| |
4
|
3 lb. 8 oz.
|
Chloraloy 240
| |
Carlisle Sure-Seal Butyl Rubber membrane
| |
DTS Chlorinated Polyethylene Water proofing
membrane manufactured by Oatey Company
|
Genoval Snap Fit
| |
Specialty Products — Triple "O" Ring
| |
W-F Products — Flexible PVC
|
Alcan Aluminum Pipe
|
Aqua-Flo Connectors — Flexible Metal Connectors
|
Bondstrand Fiberglass Pipe — Potable Water
|
Brass Craft Polylock Fitting
|
Broan Ductless Fan Model 686-686SF Air Freshener
|
Canplas/Backwater Valve — Residential
|
ETI Ultra Rib Sewer Pipe
|
Facet Glos Lavs
|
Fernco Flexible Fittings
|
Fernco Coupling Model 1059
|
Flushtrol Flush Valve
|
Forge Welded Copper Tubing WK WL WM
|
Grabber Fitting for potable water
|
IFO Cascade — Ultra low flushtoilet
|
Leisure Jetted Whirlpool Bath
|
Oasis Drinking Fountain — Drainless free
standing
|
Raychem HWAT System
|
Raypak — Heating and Potable Water System
|
Rothenberger R System
|
T. Drill
|
Black & Galvanized Steel Pipe
|
ANSI B125.270-ASTM A12-69
|
Cast Iron Pressure Pipe
|
ANSI A21.1-67 — ASTM A377-79
|
Cast Iron Pressure Pipe Fittings
|
ANSI A21.10-71
|
Cast Iron Screwed Fittings (125 and 250 lbs.)
|
ANSI B16.4063 — ASTM A126.66
|
Cast Iron Soil Pipe and fittings Extra heavy
and Service Weight
|
ANSI A112.5.1-68 — ASTM A74-82
|
Hubless Cast Iron Sanitary System with No-hub
System Fittings
|
CISPI — 301-82
|
Cast Iron Threaded Drainage Pipe
|
ANSI A40.5-43
|
Cast Iron Threaded Drainage Fittings
|
ANSI B16.12-77
|
Cast Iron Water Pipe 2" x 2 1/2"
|
ANSI — A21.12-71 — AWWA 112.65
|
Malleable Iron fittings, (Threaded) 150 lbs.
|
ANSI B16.3-77
|
Galvanized Pipe and Fittings
|
FS — WWP-40BB(1)-64
|
Wrought Iron Pipe
|
ANSI B34.2-66 — ASTM A72-66
|
Pipe Threads (except drymeal)
|
ANSI — B2.1-68
|
Valves, Cast Iron, Gate, 125 and 250 lbs. Threaded
and Flanged
|
F.S. WW-V-589-66
|
Cast Bronze Fittings for Flared Copper Tubes
|
ANSI — B16.26-75
|
Cast Bronze Screwed Fittings (125 and 250 lbs.)
|
ANSI — B16.15-78
|
Cast Bronze Solder Joint Drainage Fittings (DWV)
|
ANSI — B16.23-76
|
Cast Bronze Solder Joint Pressure Fittings
|
ANSI — B16.18-78
|
Bronze Flanges and Flanged Fittings (150 &
300 lbs.)
|
ANSI — B16.24-62
|
Copper Pipe S.P.S.
|
ANSI — H26.1-67
|
ASTM — B42-83
| |
Copper Pipe Threadless (TP)
|
ANSI — H23/3-67
|
ASTM — B75-81a
| |
Seamless Copper Tube
|
ANSI — H23.3-67
ASTM — B75-62
|
Copper Water Tube Types K.L. & M.
|
ANSI — H23.3-67
ASTM — B88-83
|
Copper Drainage Tube Type DWV
|
ANSI — H23.6-67
ASTM — B306.81
|
Seamless Brass Tube
|
ANSI — H23.6-67
|
ASTM — B135.71a
| |
Seamless Red Brass Pipe
|
ANSI — H27.1-67
ASTM — B43-80
|
Wrought Copper and Bronze Solder Joint Pressure
Fittings
|
ANSI — B16.22-80
|
Wrought Copper and Wrought Copper Alloy Solder
Joint Drainage Fittings
|
ANSI — B16-29-80
|
Lead Pipe and Traps
|
FS WW-P-350b-76
|
Unions, Brass and Bronze, 250 lbs.
|
FS WW-U-516a-67
|
Valve, Ball
|
FS WW-V-35a-65
|
Valves, Bronze; Angle, Check and Globe, 125
& 150 lbs; threaded and Flanges
|
FS WW-V-51a-(2)-54
|
Valves, Bronze; Gate, 125 & 150 lbs, Threaded
& Flanged
|
FS WW-V-54c-66
|
Pipe Fittings, Bronze and Ferrous (bushings,
plugs and locknuts) threaded
|
FS WW-P-471a(2)-64
|
ASTM
|
NSF
| |
---|---|---|
ABS PI; Sch. 40 & 80
|
D-1527
|
No. 14 P.W.
|
SDR.PR
|
D-2282
|
No. 14 P.W.
|
Composite Sewer Pipe
|
D-2680
| |
ABS Fittings; Socket Sch.40
|
D-2468
|
No. 14 P.W.
|
Socket Sch.80
|
D-2469
|
No. 14 P.W.
|
Threaded Sch.80
|
D-2465
|
No. 14 P.W.
|
ABS-DWV Pipe & Fittings; DWV Sch.40
|
D-2661
|
No. 14 P.W.
|
Sewer
|
D-2751
| |
Composite Sewer Pipe
|
D-2680
| |
ABS Solvent Cement
|
D-2235
| |
PVC Pipe:
| ||
Sch. 40,80,120
|
D-1785
|
No. 14 P.W.
|
SDR-PR
|
D-2241
|
No. 14 P.W.
|
PVC Tubing
|
D-2740
|
No. 14 P.W.
|
PVC Fittings:
| ||
Socket Sch.40
|
D-2466
|
No. 14 P.W.
|
Socket Sch.80
|
D-2465
|
No. 14 P.W.
|
Threaded Sch.80
|
D-2464
|
No. 14 P.W.
|
PVC — Bell — End Pipe: Bell Socket
Joints
|
D-2672
|
No. 14 P.W.
|
Socket Line Couplings: Sch.40 & 80
|
D-3036
|
No. 14 P.W.
|
PVC-DWV Pipe and Fittings:
| ||
DWV Pipe, Sch.40
|
D-2665
|
No. 14 P.W.
|
PVC Sewer Pipe
|
D-2729
| |
Sewer, Type PSP
|
D-3033
| |
Sewer, Type PSM
|
D-3034
| |
PVC Solvent Cement
|
D-2564
| |
CPVC Pipe, Fittings and Cement
|
D-2846 H&C-W.D.
|
No. 14 P.W.
|
PE Pipe: Sch. 40 & 80 O.D.
| ||
Base
|
D-2477
|
No.14 P.W.
|
SDR-PR, I.D. Base
|
D-2239
|
No.14 P.W.
|
PE Tubing
|
D-2737
|
No.14 P.W.
|
PE Smooth Wall
|
D-3350
|
No.14 P.W.
|
Corrugated PE Drainage Tubing
|
F-405-77a
| |
PE Fittings Butt Fusion, Sch. 40
|
D-2610
|
No.14 P.W.
|
Butt Fusion, Sch. 80
|
D-2611
|
No.14 P.W.
|
Socket Fusion for SDR 11.0 PE Pipe
|
D-2683
|
No.14 P.W.
|
PB Pipe:
| ||
SDR-PR, I.D. Base
|
D-2662
|
No.14 P.W.
|
SDR-PR, O.D. Base
|
D-3000
|
No.14 P.W.
|
PB Pipe
|
D-3309 H&C-W.D.
|
No.14 P.W.
|
PB Tubing
|
D-2666
|
No.14 P.W.
|
PB Tubing
|
D-3309 H&C W.D.
|
No.14 P.W.
|
Plastic Insert Fittings for PE & PB Pipe
|
D-2609
|
No.14 P.W.
|
SR Pipe & Fittings
|
D-2852
| |
SR Solvent Cement
|
D-3122
| |
Plastic DWV Fitting Patterns
|
D-3311
| |
Asbestos Cement Non-Pressure Sewer Pipe
|
ASTM C428-81
| |
Asbestos Cement Building Sewer Pipe
|
ASTM-C644-71
| |
Asbestos Cement Pressure Water Pipe
|
ASTM-C296-83
| |
Asbestos Cement Perforated Drain Pipe
|
ASTM C508-83
| |
Bituminized Fiber Sewer Pipe and Fittings
|
ASTM D1861-83
| |
Clay Drain Tile
|
ASTM C4-81
| |
Perforated Bituminized Fibert Drain Pipe
|
ASTM D2312, D2313-65
| |
Vitrified Clay Sewer Pipe, Standard Strength
|
ASTM C-13-65
| |
Vitrified Clay Sewer Pipe, Extra Strength
|
ASTM C200-65
| |
Vitrified Clay Sewer Pipe, Perforated Standard
and Extra Strength
|
ASTM C211-68
| |
Clay Pipe Flexible Joint (compression)
|
ASTM C425-82
| |
Concrete Sewer Pipe
|
ASTM C14-82
| |
Concrete Sewer Pipe, reinforced
|
ASTM C76-83
|
Automatic Relief Valves
|
ANSI Z21.22-79
|
Pressure Reducing Valves for domestic water
Supply Systems
|
ASSE No. 1003-81
|
Brass Cleanout Plugs
|
CS 188-66
|
Caulking Lead, Type I
|
FS-QQ-C-40-63
|
Cement Lining for Cast Iron Pipe
|
ANSI — A21.4-64
|
Chlorinated Polyethylene Sheeting for Shower
Pans
|
ASTM D4068-81
|
Coal-tar Enamel, Protective Coating
|
AWWA — C203-66
|
Compound — Plumbing Fixture Setting
|
FS — TT-P-1536a-77
|
Compression Couplings for Vitrified Clay Plain
End Pipe
|
ASTM — C594-74
|
Compression Joints, Vitrified Clay Pipe Bell
and Spigot Pipe
|
ASTM — C425-82.
|
Copper Sheet, Strip, Plate and Rolled Bar
|
ASTM — B152-83
|
Flange Dimensions, Standard (classes 125 &
250 Cast Iron Flanges, classes 250, 250 & 300 Bronze Flanges)
(land Use)
|
FS-WW-F-406a(1)-43
|
Gaskets, Plumbing Fixture Setting
|
FS-HH-C-116-36
|
Grease Interceptors
|
PDI-G101-82
|
Hangers and Supports, Pipe
|
FS-WW-H-171C(1)-64
|
Plastic Oddities — No Wax Flexible Toilet
Seal Gasket
| |
Plastic Oddities — Back water valves (French
Drain Only)
| |
Rubber Gasketed Joints for Cast Iron and Ductile
Iron Pressure Pipe and Fittings
|
ANSI — A21.11-72
|
Rubber Gaskets for Cast Iron Pipe and Fittings
|
ASTM — C564-82
|
Rubber rings for Asbestos — Cement Pipe
|
ASTM C1869-82
|
Rubber Gaskets for Concrete Sewer Pipe
|
ASTM C433-79
|
Sheet Lead, Grade A
|
FS-QQ-L-201F-2-70
|
Soft Solder
|
FS-QQ-S-571d-63
|
Water Hammer Arresters
|
ANSI — A112.26.1-69; ASSE 1010-82
|