106.6.2. Fee schedule. The fees
for plumbing work shall be as provided for by this chapter.
|
In place of the insertions in the model code text, it shall be clearly understood that all violations of the adopted codes of the City of Nashua shall be subject to the provisions of NRO Chapter 74 and RSA 676:15-17-b, without limitation of any remedy available to the City of Nashua at law or equity.
|
36 inches (914.4 mm)
|
Pertains to building sewers serving septic systems
| |
48 inches (1,219.2 mm)
|
Pertains to other building sewers
|
Where insulated, the Code Official may accept
lesser depths of building sewer placement.
|
501.6. Water temperature control in piping
from tankless water heaters. The temperature of water from
tankless water heaters intended for domestic or personal hygiene use
shall be a maximum of 130° F. (55° C.). A tempering device
conforming to ASSE 1017 shall be installed to control the water temperature.
This provision shall not supersede the requirements for protective
shower valves in accordance with Section 424.4.
|
Water temperatures supplying faucets for domestic
or personal hygiene use shall be limited to a maximum of 130°
F. (55° C.).
|
501.9. Minimum water heater temperatures.Water heaters and indirect-fired hot-water storage tanks shall be
maintained at a minimum temperature of 140° F. (60° C.) and
shall be equipped with a temperature-controlling device conforming
to ASSE 1017 to provide for maximum hot-water temperatures to faucets
in accordance with Section 501.8.
|