Mobile homes shall be structurally sound, effectively
insulated and capable of sustaining designed dynamic loading.
A. Body and body framing.
(1) Body frames shall be designed and constructed as complete
units. Wall and floor surfaces shall be firmly attached to body framing
members. Doors and windows shall be securely framed in place. Framing
and exterior skin shall be surface-treated or painted to prevent deterioration.
(2) Roofs shall be pitched for proper drainage and shall
be weathertight. Roof decks shall be of metal or noncombustible materials.
(3) Wood body framing shall be of seasoned lumber and
shall provide adequate support and rigidity. Members shall be joined
so as to ensure permanent attachment to each other.
(4) Metal body framing shall be of structural formed sections,
riveted, bolted or welded together. Where different metals are joined,
precaution shall be taken to prevent electrolytic action.
(5) Insulation of floors, roof and exterior walls shall
consist of noncombustible materials.
(6) Ventilation shall be provided to minimize deterioration
of structural members from condensation or other causes.
B. Chassis.
(1) The chassis shall extend substantially the length
of the body and shall be capable of supporting the live and dead loads
to which subjected.
(2) The tongue or drawbar shall be secured to the chassis
and shall be capable of supporting the weight of the forward end of
the mobile home. If designed to support gas cylinders, the tongue
shall be of sufficient strength and shall permit secure attachment.
(3) The hitch shall be securely attached to the tongue
so as to become an integral part of the tongue.
(4) Axles, spring assemblies and wheels shall be capable
of supporting the calculated loads.
C. Placement. The placement of a mobile home on a mobile
home stand by jacks or supports shall be such as to ensure the retention
of the mobile home in a fixed position.
A mobile home shall be maintained in a safe
and sanitary condition.
A. Interior. Floors, walls, ceilings, furnishings and
fixtures shall be maintained in a clean and sanitary condition. Exits
shall be maintained free of obstructions.
B. Garbage and refuse. Suitable containers shall be provided
for the temporary storage of garbage and refuse within the mobile
home.
C. Screening. From May 1st to October 1st, entrances
to the mobile home shall be provided with self-closing-type devices
or screens, and windows and other openings used for ventilation shall
be appropriately screened.
D. Extermination. Mobile homes shall be maintained free
from insects, vermin and rodents. Extermination shall be effected
in conformance with generally accepted practice.
E. Flammable materials. Flammable cleaning liquids and
other flammable materials shall be stored in a safe, approved manner.