[Ord. No. 5906 §3(12a.1), 10-25-2005]
The general intent of these regulations and standards is to minimize the impact of future development within the Clayton Road Urban Design District ("CR-UDD") on adjacent residential neighborhoods, promote a mixed-use/residentially-oriented pattern of development that is more compatible with the adjacent neighborhoods than traditional commercial uses found in other areas of the Clayton Road corridor, to increase the predictability and flexibility of future development within the "CR-UDD" and to maintain the "CR-UDD" a visually appealing gateway for the City of Clayton and the adjacent neighborhoods.
[Ord. No. 5906 §3(12a.2), 10-25-2005]
The Clayton Road ("C-2") Urban Design Zoning District encompasses the properties fronting the north side of Clayton Road from Big Bend Boulevard to the east City limits as depicted on the map below:
410-680.tif
[Ord. No. 5906 §3(12a.3), 10-25-2005]
The regulations of this urban design zoning district shall supersede or supplement, as applicable, the regulations of the base zoning district. Where conflict results between the regulations of the urban design zoning district and the provisions of the base zoning district, the provisions of the urban design zoning district shall control.
[Ord. No. 5906 §3(12a.4), 10-25-2005]
The uses permitted by right and by conditional use permit are listed in the Table of Permitted Uses found at the end of this Article. If a "P" (permitted by right) or a "C" (permitted by conditional use permit) is not indicated for a use in the Table, it is prohibited.
[Ord. No. 5906 §3(12a.5), 10-25-2005]
This Section provides definitions specific to the "CR-UDD". Definitions governing all urban design districts inclusive of the "CR-UDD" are found in Chapter 405.
LIVE/WORK UNIT
A structure with a combination of uses where work activities occur and a dwelling unit is included for the business occupant. Such unit shall have only one (1) kitchen and not more than fifty percent (50%) of the structure shall be dedicated for a business use. The dwelling unit shall be occupied by either the owner, the tenant or the owner or tenant's employee. The residence must be the residence of a person responsible for the work performed on the premises.
MAXIMUM EXTENT PRACTICABLE
It is the responsibility of the developer to show clearly and convincingly to the satisfaction of the Plan Commission that, under the circumstances, reasonable efforts have been undertaken to comply with the regulation or requirement, that the cost of additional compliance measures clearly outweigh the potential benefits to the public or would unreasonably burden the proposed project and reasonable steps have been undertaken to minimize any potential harm or adverse impacts resulting from non-compliance.
MIXED-USE DEVELOPMENT
Development containing a mix of complimentary uses within the same building. Typically, mixed-use buildings contain some combination of retail, office and residential uses, with retail uses located at the ground floor and office or residential uses located above. Residential uses shall contain a floor area no less than seven hundred fifty (750) square feet.
[Ord. No. 5906 §3(12a.6), 10-25-2005]
A. 
This Section provides the following standards designed to maintain the pedestrian-oriented, landscaped character of the front setback (where still evident), to avoid creating an imposing, "canyon" of taller buildings along Clayton Road and to establish intersections within the "CR-UDD" as prominent gateways to the adjacent neighborhoods.
B. 
Front setback may be reduced to twelve and one-half (12.5) feet for mixed-use development located on corner lots. Reduced setback shall be allowed within sixty (60) feet of the applicable intersection (as measured from the property line at the back of the sidewalk) and shall only be applicable to lots adjacent to the following intersections:
1. 
DeMun Avenue and Clayton Road;
2. 
Seminary Place and Clayton Road;
3. 
St. Rita Avenue and Clayton Road; and
4. 
Concordia Lane and Clayton Road.
[Ord. No. 5906 §3(12a.7), 10-25-2005]
A. 
This Section is intended to minimize the impact of paving and other hard materials that can detract from the existing green, landscaped character desirable along the north Clayton Road frontage and to maintain the green, landscape character of the front setback where still evident.
1. 
Residential and mixed-use developments shall have no more than thirty percent (30%) of the required front yard setback covered by impervious material. This standard shall not be applicable to commercial development and shall only be applicable to the portion of a corner development where a reduced front setback is not permitted. If a corner development does not opt to reduce the front setback for the area permitted, the above provision would apply to the entire lot frontage.
2. 
Surface parking shall be prohibited between the site's primary building and Clayton Road.
[Ord. No. 5906 §3(12a.8), 10-25-2005]
A. 
This Section is intended to maintain the traditional orientation of buildings and the pedestrian-oriented character of development along the Clayton Road frontage.
1. 
The primary entrance of all new structures shall be oriented towards Clayton Road.
[Ord. No. 5906 §3(12a.9), 10-25-2005; Ord. No. 6430 §1, 6-14-2016]
A. 
This Section provides the following standards to enhance and soften the appearance of new development as viewed from adjacent neighborhoods and Clayton Road, to ensure parking and service areas are screened from adjacent neighborhoods and Clayton Road, and to maintain the tree lined appearance of the Clayton Road frontage by protecting the established tree canopy within the district. Specific requirements are set forth in Article XXX: Trees and Landscaping Regulations.
1. 
The perimeter of all surface parking and service areas shall be screened using one (1) of the following methods:
a. 
A low continuous landscaped hedge a minimum of three (3) feet high, consisting of a double row of shrubs planted three (3) feet on center in a triangular pattern, or
b. 
A low masonry wall or fence three (3) feet high in combination with landscaping (landscaping shall be planted between the wall and the public right-of-way, sidewalk or boundary).
2. 
Existing tree lawns shall be retained as part of any redevelopment project. In instances where the tree lawn has been removed previously, it shall be re-established as part of any redevelopment project.
3. 
Retaining walls shall not exceed five (5) feet in height. Where a larger wall is required to create a transition in grade, a landscape terrace, a minimum of three (3) feet in depth, shall be provided between each five (5) foot wall section.
[Ord. No. 5906 §3(12a.10), 10-25-2005]
A. 
This Section provides the following standards to maintain light access and air circulation for adjacent residential neighborhoods and to maintain visual breaks in development along Clayton Road, particularly when multiple lots are consolidated for a single development.
1. 
A five (5) foot side yard setback shall be provided for all development within the "CR-UDD" with the following exception:
a. 
Town house development:
(1) 
Required side yard setbacks may be reduced or eliminated to allow for creativity in building design, however, the following additional standards shall apply:
(a) 
Building heights shall not exceed three (3) stories or forty-five (45) feet above the average existing grade, whichever is less;
(b) 
Total building length shall not exceed one hundred ten (110) feet and shall contain the required offsets specified in these standards (Partial stories with dormers or sheds may be permitted under sloping roofs. Partial stories shall be completely contained beneath the slope of the roof line); and
(c) 
A five (5) foot side yard setback shall be provided on either end of a multi-unit town home structure where the structure is adjacent to an existing structure or a property not under ownership of the applicant.
[Ord. No. 5906 §3(12a.11), 10-25-2005]
A. 
This Section provides the following standards to maintain visual relief between residential lots south of the alley within the Hi-Pointe/DeMun neighborhood and new development within the "CR-UDD" and to minimize shadowing of residential lots north of the alley.
1. 
A landscape buffer a minimum of four (4) feet shall be provided along the rear building wall to soften its appearance when viewed from the alley or adjacent residences. The landscape buffer shall include evergreen shrubs with an upright growth habit that are a minimum of five (5) feet tall at the time of installation and are spaced a maximum of four (4) feet on center. A variety of other complementary planting material shall also be incorporated to provide visual interest.
2. 
The following incentives shall be provided to increase buffering and open space for by right mixed-use developments:
a. 
Floor area ratio may be increased by 0.1 above the 1.5 floor area ratio maximum for:
(1) 
Each two hundred (200) square feet of usable open space provided in the form of a central courtyard opening onto the alley; or
(2) 
Each additional two (2) feet added to the minimum rear setback.
b. 
The maximum floor area ratio that may be achieved using this incentive shall be two (2.0).
[Ord. No. 5906 §3(12a.12), 10-25-2005]
A. 
This Section provides the following standards to mitigate stormwater runoff caused by new development within the "CR-UDD" onto properties in the adjacent residential neighborhoods.
1. 
To the maximum extent feasible, development shall follow and respect the existing topography of the site. The finished grade of the front yard shall match that of adjacent properties to avoid creating a "stepped" appearance along the Clayton Road frontage.
2. 
Site drainage patterns shall be designed so as to minimize concentrated surface drainage and runoff onto adjacent properties.
3. 
Stormwater drainage shall be connected to a storm sewer where available.
[Ord. No. 5906 §3(12a.13), 10-25-2005]
A. 
This Section provides the following standards to ensure that future development provides an attractive gateway to the City of Clayton, incorporates materials that are compatible with the traditional development character found in the district and adjacent residential neighborhoods and to use materials that provide a sense of permanence and quality.
1. 
Primary building materials shall be limited to masonry materials such as brick or a combination of brick and stone, as traditionally found within the district and adjacent residential neighborhoods. All materials shall be similar in color, texture and scale as those traditionally found within the district and in adjacent residential neighborhoods and the Hi-Pointe/DeMun Historic District. Materials characteristic of the Hi-Pointe/DeMun Historic District include:
a. 
Decorative terra cotta tile (either red unglazed or green glazed) and slate roof accents;
b. 
Decorative brick patterns;
c. 
Cut stone foundations and accents;
d. 
Varied, but muted, brick colors including greens, tans, yellows and browns;
e. 
Varied brick textures ranging from smooth faced to heavily textured; and
f. 
Varied mortar colors including brown, red, light gray and sand, but with black being predominate.
2. 
The following materials shall not be permitted for use as primary building materials or accent materials:
a. 
EIFS;
b. 
"Jumbo" brick;
c. 
Split-faced block; or
d. 
Stucco.
3. 
Retaining walls shall be constructed of materials similar in color, texture and scale as the primary building materials. The following materials shall not be used for any retaining walls visible from Clayton Road, the alley or any adjacent property:
a. 
Wood ties;
b. 
Keystone;
c. 
Windsor; or
d. 
Similar modular block wall systems.
4. 
All exposed concrete walls (such as for the exterior walls of enclosed parking areas) shall be faced with the primary building material and/or a predominant accent material.
[Ord. No. 5906 §3(12a.14), 10-25-2005]
A. 
This Section provides the following standards to ensure that height, mass and bulk of new development does not adversely affect the character of adjacent residential properties or the quality of life of neighboring residents, to maintain visual breaks along Clayton Road, particularly when multiple lots are consolidated for a single development, to maintain light access and air circulation for adjacent residential neighborhoods and emphasize the role of the "CR-UDD" as a gateway to adjacent neighborhoods.
1. 
Buildings that exceed three (3) stories or forty-five (45) feet in height shall step down to the height of the adjacent rear building elevation or thirty (30) feet, whichever is greater. The height of the adjacent rear building elevation shall be measured from the average existing grade of the site to the peak of the roof. The depth of each step shall be a minimum of fifteen (15) feet.
2. 
The following incentive shall be provided to encourage a reduction in total building height for by right mixed-use development:
a. 
An increase in floor area ratio of 0.1 above the 1.5 floor area ratio maximum may be granted for each two (2) foot reduction in height below the allowable maximum.
b. 
The maximum floor area ratio that may be achieved using this incentive shall be two (2.0).
(Note: The ability of an applicant to seek an increased FAR through the "PUD" process would not be affected.)
3. 
A shadow study shall be provided for all new development that exceeds thirty-five (35) feet in height. Such study shall be funded by the applicant and shall be conducted by an independent contractor to the City. The study shall demonstrate that shadows would not have a significant adverse affect on neighboring residents.
4. 
Where multiple lots have been assembled, resulting in a combined lot that is significantly larger than the traditional forty (40) foot lot width typically found within the district, the following standards shall apply:
a. 
For buildings that exceed three (3) stories or forty-five (45) feet in height, one (1) of the following standards or combinations of standards shall apply:
(1) 
Option A:
(a) 
The total length of buildings shall be limited to eighty (80) feet; and
(b) 
Variation in the building facade shall be provided using a combination of accent materials, offsets, windows and other features.
(2) 
Option B:
(a) 
The total length of buildings may be increased to a maximum of one hundred sixty-five (165) feet provided that the building is organized as a series of smaller building modules defined by a gap or separation in the building facade to allow light to penetrate through the "CR-UDD" to the adjacent neighborhood.
(b) 
The gap or separation shall:
(i) 
Be a minimum of five (5) feet in width;
(ii) 
Extend from the top of the first (1st) floor of the building to the top of the roof for buildings up to four (4) stories or fifty-two (52) feet in height; and
(iii) 
Extend from the top of the second (2nd) story of the building to the top of the roof for buildings that exceed four (4) stories or fifty-two (52) feet in height.
(iv) 
For the purposes of satisfying the above standards, the width of building modules may vary dependent upon the total length and design of the building, however, no individual building module shall exceed eighty (80) feet in length.
(3) 
Option C: The total length of a building may be increased to a maximum of one hundred sixty-five (165) feet provided that the building is organized in a courtyard or "u-shaped" configuration and that the courtyard is a minimum of twenty-five (25) feet deep (as measured from the front setback) and a minimum of forty (40) feet in length.
(4) 
Option D:
(a) 
The total length of a building may be increased to a maximum of one hundred sixty-five (165) feet provided that a minimum of three (3) offsets are provided along the front facade of the building.
(b) 
Offsets shall be a minimum of five (5) feet in depth.
b. 
For buildings that are less than three (3) stories or forty-five (45) feet in height, the following standards shall apply:
(1) 
The total length of buildings shall be limited to eighty (80) feet; and
(2) 
Variation in the building facade shall be provided using a combination of accent materials, offsets, windows and other features.
[Ord. No. 5906 §3(12a.15), 10-25-2005]
A. 
This Section provides the following standards to ensure that new development is compatible with the traditional character of original structures within the district and that of adjacent neighborhoods.
B. 
New structures shall incorporate architectural detailing that is compatible with the traditional character of original structures found in the "CR-UDD" and that of structures in adjacent neighborhoods and the Hi-Pointe/DeMun Historic District (i.e., scale and types of materials, roof treatments or other similar features). Architectural accents characteristic of the Hi-Point/DeMun Historic District include:
1. 
Decorative terra cotta roof tile accents;
2. 
Contrasting brick work and limestone or terra cotta accents; and
3. 
Divided light windows above the first (1st) floor level for mixed-use buildings.
C. 
"Warehouse" style architecture typically characterized by a blocky form, flat roof lines and sparse architectural detail shall be prohibited.
D. 
Blank walls, void of windows or architectural detailing are prohibited. All facades visible from Clayton Road frontage or other public right-of-way (including the alley) shall incorporate a similar level of wall articulation and architectural detailing as the front facade.
E. 
Mixed-use and commercial structures shall incorporate large "storefront" windows, architectural detailing and other features at the ground level to maintain a pedestrian-friendly environment at the street edge.
[Ord. No. 5906 §3(12a.16), 10-25-2005]
A. 
The following Section provides revisions to the base "C-2" zoning district regulations in the "CR-UDD" in order to allow for a broader range of uses within the "CR-UDD" to promote neighborhood compatibility and to enhance opportunities for the future redevelopment of mid-block lots, to encourage mixed-use development within the "CR-UDD", particularly at key intersections, where access can be more easily managed and mixed-use can help reinforce these locations as gateways to the adjacent neighborhood, to limit auto-intensive uses that are incompatible with and could potentially be disruptive to adjacent residential neighborhoods and to promote uses within the "CR-UDD" (such as live/work) that generate low volumes of traffic, making them more compatible with adjacent residential neighborhoods.
1. 
For properties located within the "CR-UDD", the following use may be permitted by right, subject to applicable design standards set forth in this Article and in the Zoning Ordinance and subject to site plan review which may include studies to evaluate the potential effects or functions of one (1) or more of the following: lighting, traffic, parking and shadowing:
a. 
Mixed-use development (see definition in Section 410.695).
2. 
Residential uses shall be prohibited on the first (1st) floor of mixed-use developments unless such units are used for live/work purposes.
3. 
For properties located within the "CR-UDD", the following uses may be permitted by conditional use permit or through the planned unit development process, subject to the design standards set forth above.
a. 
Live/work development (see definition in Section 410.695). Such uses are required a live/work occupancy permit to be renewed on an annual basis for the first (1st) three (3) years of such use. Staff will submit an annual report to the City's Plan Commission regarding live/work uses each January for three (3) years.
4. 
Live/work developments containing four (4) or less units shall provide parking as follows:
a. 
One and one-half (1.5) spaces per residential unit and two (2) spaces per one thousand (1,000) square feet of business space.
5. 
Live/work developments containing more than four (4) units shall provide a parking study that demonstrates adequate parking will be provided.
6. 
The following uses may be permitted by conditional use permit or through the planned unit development process, subject to the design standards set forth in this Article and in the Zoning Ordinance:
a. 
Multi-family residential development; and
b. 
Town home residential development.
7. 
To maintain corner properties for commercial and mixed-use development, single-use residential development shall not be permitted within sixty (60) feet of the following intersections:
a. 
DeMun Avenue and Clayton Road;
b. 
Seminary Place and Clayton Road;
c. 
St. Rita Avenue and Clayton Road; and
d. 
Concordia Lane and Clayton Road.
8. 
The following uses shall be prohibited within the "CR-UDD":
a. 
Utility, utility station or substation;
b. 
Gasoline and oil service stations;
c. 
Car wash establishments;
d. 
Surface parking as a primary use; and
e. 
Structured parking as a primary use.
9. 
Surface and structured parking shall continue to be permitted as a primary use for municipal purposes.
[Ord. No. 5906 §3(12a.17), 10-25-2005]
PERMITTED USES FOR "CR-UDD"
Academy (including dancing, painting, theater, karate and similar disciplines).
P
Accessory uses and buildings incidental to permitted uses.
P
Amateur radio, home antennas and associated equipment (subject to Article XXVI of Chapter 405).
P
Art gallery or studio.
P
Automobile agencies.
P
Bakeries limited to the processing of bakery goods for sale only on the premises and consumption off the premises.
C
Banks, savings and loans, credit unions and other financial institutions.
P
Banquet facilities.
P
Catering establishment.
P
Church spires, belfries, monuments, ornamental towers and spires and chimneys exceeding the maximum height in the zoning district may be erected to such height authorized by the Board of Aldermen of the City by conditional use permit or general ordinance.
P
Commercial antennas (subject to Article XXVI of Chapter 405).
P
Day care, nursery, pre-kindergarten, play and special schools and kindergarten.
C
Drive-through establishments for financial institutions.
C
Dry cleaning and dyeing establishment.
P
Funeral homes, mortuaries and undertaking establishments.
C
Grocery stores.
C
Health clubs.
C
Hotel.
C
Institution — Public buildings, hospitals, institutions or schools, when permitted in a district, may be erected to a height not exceeding 110 feet if the building is set back from each yard line at least 1 foot for each foot of additional building height above the height limit otherwise permitted in the district in which the building is built.
C
Kiosk (subject to the provisions of Article II, Section 405.310).
P
Laundry shop — either drop-off or self-service providing no more than 30 machines.
P
Live/work unit (per definition in Section 410.695).
C
Lodge hall or club.
C
Marijuana Dispensary Facility (subject to the performance standards set forth in Section 405.350)
C
Marijuana Testing Facility (subject to the performance standards set forth in Section 405.350)
C
Medical or dental clinic.
P
Messenger and telephone exchange building.
P
Microbreweries.
P
Mixed-use developments (per definition in Section 410.695).
P
Nursing and convalescent home.
C
Offices — Business or professional.
P
Pharmacies.
P
Place of religious worship.
P
Public buildings erected or used by any department of the City, County, State or Federal Government. Public buildings, hospitals, institutions or schools, when permitted in a district, may be erected to a height not exceeding 110 feet if the building is set back from each yard line at least 1 foot for each foot of additional building height above the height limit otherwise permitted in the district in which the building is built.
C
Public interest signs.
C
Recreation building or structure or grounds.
P
Residential — multi-family residential development or town home development.
C
Restaurants (including carry-out, self-seating and full-service) and prepared food dispensing uses.
C
Retail establishments.
P
Schools for business, professional and technical training, but not including outdoor areas for driving or heavy equipment training.
C
Theaters, both live performance and movies.
C
P = Permitted by right
C = Permitted with conditional use permit