[Ord. 2004-O-11, 6/23/2004, § 1]
1. The 2003 International Building Code is amended as follows:
A. Chapter
15, § 1510.3, is hereby amended by adding a new subsection:
1510.3.1 Reroofing when fire-rated plywood underlayment is present.
"New roof coverings shall not be installed without first removing
all existing roof coverings, including the fire-rated plywood underlayment,
where any of the following conditions occur:
1. Where the existing roof or roof covering is water soaked or has deteriorated
to the point that the existing roof or roof covering is not adequate
as a base for additional roofing.
2. When the existing roof covering is wood shake, slate, clay, cement
or asbestos-cement tile.
3. Where the existing roof has two or more applications of any type
of roof covering.
4. Where the existing FRT roof of an attached building was constructed
prior to January 1, 1992.