[Ord. 1996-1, 1/23/1996, § 1500]
1. Off-street parking facilities shall be provided to lessen congestion
in the streets. The facilities required herein shall be available
to patrons throughout the hours of operation of the particular business
or use for which such facilities are provided. As used herein, the
term "parking space" includes either covered garage space or uncovered
parking lot space located off the public right-of-way.
2. Each parking space shall consist of not less than an average of 300
square feet of usable area, for each motor vehicle, including interior
driveways. Notwithstanding the above, all parking spaces shall be
ample in size for the vehicles for which use is intended. The net
parking space per vehicle shall not be less than 10 feet wide and
18 feet long. Parking spaces and the approaches thereto, shall be
stone, gravel, or paved. Whenever parking spaces are opposite each
other and separated by a driveway, said driveway shall be not less
than 20 feet in width.
3. A garage or carport may be located wholly or partially inside the
walls of the principal building, or attached to the outer walls. The
garage may be constructed under a yard or court provided that the
level of such yard or court shall conform to the general level of
the other yards or courts on the lot. The space above an underground
garage shall be deemed to be part of the open space on the lot on
which it is located.
4. Except for residential uses in A, RL, and RM Districts, parking lots
shall be considered as a building for the purpose of determining applicable
setback requirements, unless adjacent to any full depth buffer zone
as required by this ordinance or as modified by other sections of
this chapter.
[Ord. 1996-1, 1/23/1996, § 1501]
1. Any building hereafter erected or converted and any lot hereafter
used shall be provided with not less than the minimum parking spaces
as set forth below, which spaces shall be readily accessible to and
within a reasonable distance from the buildings served thereby. Such
spaces shall be on the same lot as the principal building or open
area, except when otherwise authorized as a special exception. No
parking space shall be provided in the front yard areas of dwelling,
apartment houses and apartment hotels, boarding or rooming houses,
churches or schools, unless authorized as a special exception, except
that in Residential Districts, off-street parking spaces are not permitted
in the front yard except that parking on a paved driveway in a front
yard is allowed. The required parking space shall be located on the
same lot as the principal building or open area in question or contiguous
to said lot whenever possible. In no case shall the required parking
space be located more than 600 feet from the principal use. Off-street
parking facilities shall be provided as follows:
A. Parking Requirements for Dwelling Units.
|
Type Dwelling Unit
|
Spaces per Dwelling Unit
|
---|
|
Dwelling
|
2.0
|
|
Apartment house and apartment houses
|
2.5 x number of dwelling units
|
B. Parking Requirements for Educational and Related Uses.
|
Educational and Related Uses
|
Required Parking Spaces
|
---|
|
Elementary schools
|
Two per each classroom and each other room used by students
plus one space per non-instructional employee.
|
|
High schools
|
Two per each classroom and each other room used by students
plus one for each 10 full-time students plus one space per non-institutional
employee.
|
|
Colleges, junior colleges, technical schools, universities and
related uses
|
As determined by the Zoning Hearing Board
|
|
Other educational uses (in addition to requirements for classroom
|
|
|
(1)
|
Fraternities, sororities, dormitories and related buildings
|
0.5 per bed
|
|
(2)
|
School auditoriums and cafeterias if used for social functions
or as meeting rooms
|
One per each four seats
|
|
(3)
|
Gymnasiums, stadiums, field houses, grandstands and related
structures and facilities, if part of a school
|
One per each four seats
|
|
(4)
|
Day care centers, nursery schools or babysitting services (not
as part of a dwelling)
|
One space per employee on maximum shifts plus spaces equal to
20% of maximum permitted occupancy
|
C. Parking Requirements for Other than Dwelling Units or Educational
Facilities.
|
Uses
|
Required Parking Spaces
|
---|
|
Rooming houses, hotels, motels and tourist houses
|
One per guest room plus one for every two full-time employees
per shift. (See separate requirements for a restaurant if part of
one of these uses)
|
|
Theaters, auditoriums, churches, stadiums or other places of
public or private assembly
|
One per three seats for public or private assembly
|
|
Retail stores
|
One per 200 square feet of gross floor area
|
|
Restaurants and bars
|
One per four customer seats plus one for every employee on the
largest shift
|
|
Office building
|
One per 200 square feet of floor area
|
|
Shopping centers
|
4.5 per 1,000 square feet of gross floor area
|
|
Industrial, wholesale and warehousing establishment (see Subsection 1G)
|
Minimum of one parking space for each employee on the two largest
shifts but not less than one parking space per each 1,000 square feet
of gross floor area, whichever is greater.
|
|
Garages or automobile and gasoline service stations
|
One per 400 square feet of floor or ground area devoted to repair
or service facilities. Shall be in addition to space allocated for
normal storage of motor vehicles.
|
|
Hospitals an sanitariums
|
One per three accommodations (bed) plus one per each employee
on the largest shift
|
|
Open areas used for commercial purposes
|
One per 1,500 square feet of area
|
|
Dance halls, roller rinks, clubs, lodges and other similar places
|
One per 100 square feet of floor area and one per each employee
on the largest shift
|
|
Fast food/drive-in establishments
|
One per two seats plus one per each employee on the largest
shift
|
|
Mortuaries, funeral homes and undertaking establishments
|
One per 100 square feet of gross floor area, one per employee
and one per each piece of mobile equipment, such as hearses and ambulances
|
|
Swimming pools
|
One per each four persons based upon design capacity of the
pool
|
|
Golf courses and country clubs
|
Six per hole or one per two accommodations (such as lockers)
whichever is greater. When such clubs are used as rentals, parking
requirements for restaurants shall apply or whichever is greater.
|
|
Professional offices of physicians, dentists and animal hospitals
and emergency medical treatment facilities
|
One per 250 square feet of gross floor area plus one per employee,
but not less than eight total.
|
|
Public libraries, art galleries, museums and nonrecreational
public facilities
|
One per each 600 square feet of floor area open to the public
|
D. In addition to all of the above minimum requirements, additional
spaces for visitor parking and salesman shall be provided according
to the specific requirements for each use.
E. No part of the public right-of-way of any street or road shall be
used in computing the required area for parking, however, parallel
parking may be permitted along the curb or edge of an access drive
or private road, providing the spaces are not less than eight feet
by 20 feet in addition the required width for the circulation of vehicles.
F. When the parking requirements are not specified herein for a building
or use for which an application for a permit has been filed, the Zoning
Hearing Board shall require that adequate off-street parking space
be provided to serve the needs of the proposed uses in conformance
with the standards set forth above, or upon consideration of all factors
entering into the parking needs of each such use:
G. For Industrial, wholesale and warehousing establishments, the Zoning
Hearing Board may authorize the reduction of the number and size of
paved off-street parking spaces as a special exception in cases where
the applicant can justify a reduction and still provide adequate parking
facilities to serve the proposed uses of the building and/or land
and show reserved areas for expansion of the paved parking for future
uses.
[Ord. 1996-1, 1/23/1996, § 1502]
In parking areas of 1/2 acre or more, at least 5% of the total
area shall be devoted to landscaping within the interior of the parking
area.
[Ord. 1996-1, 1/23/1996, § 1503]
Unobstructed access to and from a street shall be provided.
Such access shall consist of at least one ten-foot lane for parking
areas with less than 20 spaces, and at least two 10 foot lanes for
parking areas with 20 spaces or more. No entrance or exit for any
off-street parking area shall be located within 50 feet of any street
intersection.
[Ord. 1996-1, 1/23/1996, § 1504]
1. All Single-family and two-family dwelling driveways shall conform
to the following:
A. The number of driveways may not exceed two per lot on a street frontage.
B. A driveway may not cross a street right-of-way line.
(1)
Within 50 feet of the right-of-way line of an intersecting street
on the same side of the street.
(2)
Within five feet of a hydrant.
(3)
Within 20 feet of another driveway on the same property.
(4)
Within three feet of the property line.
(5)
Driveways accessing a state highway are allowed only by virtue
of a permit issued by the Pennsylvania Department of Transportation
and no development will be approved without such permit.
C. Driveways may not exceed 20 feet at the right-of-way line.
D. Driveways must be located in safe relationship to sight distance
and barriers to vision. The drive may not exceed a slope of 7% within
15 feet of the street right-of-way line. Where a drive enters a bank
through a cut, the shoulders of the cut may not exceed 50% in slope
within 25 feet of the point the drive intersects the right-of-way.
E. A clear sight triangle in conformance with the Subdivision and Land Development Ordinance [Chapter
22] shall be provided for driveways.
F. Residential single family and single family attached dwelling may
utilize driveways as part of required parking.
G. Any residential dwelling located along and accessing directly an
arterial or collector street shall provide an area to be utilized
as turnaround area-minimum size nine by 10 to the side of the main
driveway so that entrance to the road can be performed in a safe manner.
[Ord. 1996-1, 1/23/1996, § 1505]
1. Number Per Lot. Except as specified elsewhere, the number of access
drives intersecting with each street shall not exceed two per lot.
The Zoning Hearing Board may grant a variance for additional access
points where required to meet exceptional circumstances and where
frontage of unusual length exists.
2. Setbacks. All access drives shall be set back at least.
A. One hundred feet from the intersection of any street right-of-way
lines.
B. One hundred feet from any other access drive or driveway located
upon the same lot (measured from cartway edges).
C. Fifteen feet from any side and/or rear property lines; however, this
setback can be waived along one property line when a joint parking
lot is shared by adjoining uses.
3. Clear-Sight Triangle. Access drives shall be located and constructed
so that a clear-sight triangle a minimum of 100 feet as measured along
the street center line and along the driveway center line is maintained;
no permanent obstructions and/or plant materials over 30 inches high
shall be placed within this area. In addition, all proposed access
drives must have a minimum adequate safe stopping sight distance base
on PennDOT standards.
4. Access Drive Width. Access drives shall provide a twelve-foot wide
cartway for each lane of travel. However, in no case shall any access
drive cartway be less than 18 feet wide. See table below for further
explanation:
|
Number of Lanes
|
Direction of Travel
|
Required Access Drive Width
|
---|
|
1
|
one way
|
18 feet
|
|
2
|
one or two way
|
24 feet
|
|
3 or more
|
one or two way
|
12 feet/lane
|
5. PennDOT Permit. Any access drive intersecting with a state-owned
road shall require the obtainment of Pennsylvania Department of Transportation
driveway permit.
[Ord. 1996-1, 1/23/1996, § 1506]
All residential and non-residential access drives and required
open parking areas shall be properly drained and all such areas shall
be paved, except that parking spaces and access drives in the A-Agricultural
District shall only be required to be paved to the front setback line.
[Ord. 1996-1, 1/23/1996, § 1507]
Required parking spaces, open or enclosed, may be provided in
spaces designated to serve jointly two or more establishments whether
or no located on the same lot, provided that the number of required
spaces in such joint facilities shall be not less than the total required
for all such establishments.
[Ord. 1996-1, 1/23/1996, § 1508]
When any lot contains two or more uses having different parking
requirements, the parking requirements for each use shall apply to
the extent of that use. Were it can be conclusively demonstrated that
one or more such uses will be generating a demand for parking spaces
primarily during periods when the other use or uses is not or are
not in operation, the Board may reduce the total parking spaces required
for that use with the least requirement.
[Ord. 1996-1, 1/23/1996, § 1509]
When two or more uses that require off-street parking spaces
are located in a single structure, the separate parking requirements
for each use shall be applied.
[Ord. 1996-1, 1/23/1996, § 1510]
1. Off-street loading, berths, open or enclosed are permitted accessory
to any use (except one or two family residences) subject to the following
minimum provisions:
A. Uses for Which Required. Accessory off-street loading berths shall
be provided for any use specified below. Any land which is developed
as a unit under single ownership and control shall be considered a
single lot for the purpose of these minimum loading requirements:
(1)
For a public library, museum, or similar quasi-public institution,
or governmental building, community center, hospital or sanitarium,
nursing or convalescent home, institution for children or the aged,
or school with floor area of 10,000 square feet, one berth; for each
additional 25,000 square feet or fraction thereto, one additional
berth.
(2)
For buildings with professional, governmental or business offices
or laboratory establishments, with floor area of 10,000 to 25,000
square feet, one berth, for each additional 25,000 square feet or
fraction thereof up to 100,000 square feet, one additional berth;
for each additional 50,000 square feet or fraction thereof, one additional
berth.
(3)
For buildings with offices and retail sales and service establishments,
berth for 8,000 to 25,000 square feet of floor area, and one additional
berth for each additional 25,000 square feet of floor area or fraction
thereof so used.
(4)
For undertakers and funeral homes, one berth for each chapel.
(Such berths shall be at least 10 feet wide, 20 feet long and 14 feet
high.)
(5)
For hotels, motels, and resorts, one berth for each 25,000 square
feet of floor area.
(6)
For manufacturing, wholesale and storage uses and for dry-cleaning
and rug cleaning establishments and laundries, one berth for 5,000
to 10,000 square feet of floor area in such use, and one additional
berth for each additional 20,000 square feet of floor area or fraction
thereof so used.
B. Size of Spaces. Each required loading berth shall be at least 12
feet wide, 40 feet long and 14 feet high.
C. Location and Access. Unobstructed access, at least 10 feet wide, to and from a street shall be provided. Such access may be combined with access to a parking lot. All permitted or required loading berths shall be on the same lot as the use to which they are accessory, except as provided in Subsection
1D. No entrance or exit for any off-street parking area shall be located within 100 feet of any street intersection. No off-street loading berth shall be located in any front yard.
D. Joint Facilities. Permitted or required loading berths, open or enclosed, may be provided in spaces designed to serve jointly two or more adjacent establishments provided that the number of required berths in such joint facilities shall not be less than the total required for all such requirements, unless the provisions of §
27-1509 apply.
[Ord. 1996-1, 1/23/1996, § 1511]
Handicapped parking shall be required for uses other than dwelling
units. Parking spaces for handicapped can be no less than 12 feet
six inches wide and must meet the requirements of the Americans with
Disabilities Act (ADA). Required minimum number of handicapped accessible
spaces include the following:
Total Parking In Lot
|
Required Minimum Number of Accessible Spaces
|
---|
1-25
|
1
|
26-50
|
2
|
51-75
|
3
|
76-100
|
4
|
101-150
|
5
|
151-200
|
6
|
201-300
|
7
|
301-400
|
8
|
401-500
|
9
|
501-1,000
|
2% of total
|
Over 1,000
|
20 plus one for each 100 over 1,000
|
[Ord. 1996-1, 1/23/1996, § 1512]
All paved areas abutting buildings where parking is prohibited