[Ord. No. 4685 §1, 12-21-2015]
This Article shall be known and may be cited as "The Explosives
Code."
[Ord. No. 4685 §1, 12-21-2015]
As used in this Article, the following terms shall have the
meanings indicated:
BLASTING AGENT
Any material or mixture consisting of a fuel and oxidizer
intended for blasting, not otherwise classified herein as an explosive,
in which none of the ingredients are classified as explosives, provided
that the finished product, as mixed and packaged for use or shipment,
cannot be detonated by means of a No. 8 test blasting cap when unconfined.
BLASTING CAP NO. 8
A No. 8 test blasting cap is one containing two (2) grams
of a mixture of eighty percent (80%) mercury fulminate and twenty
percent (20%) potassium chlorate or a cap of equivalent strength.
DIRECTOR
The Planning and Development Services Director and includes
his/her authorized agents.
EXPLOSIVES and EXPLOSIVE MATERIALS
Gunpowder used for blasting, all forms of high explosives,
fuses, detonators and other detonating agents, smokeless powders,
and any chemical compound or mechanical mixture that is commonly used
or intended for the purpose of producing an explosion containing any
oxidizing and combustible units or other ingredients in such proportions,
quantities, or packing, that ignition by fire, by friction, by concussion,
by percussion, by detonation of, by any part of the compound or mixture
may cause such a sudden generation of highly heated gases that the
resultant gas pressures are capable of producing destructive effects
on contiguous objects or of destroying life or limb; but explosives
shall not include small arms ammunition, gasoline, kerosene, or oils,
greases or other petroleum products intended for lubrication purposes.
For the purposes of this Article, explosives shall be classified as
Class A, high explosives, and Class B, low explosives, and said classifications
shall be as follows:
1.
Class A, high explosives: Those explosives possessing detonating
qualities such as dynamite, nitroglycerin, picric acid, lead azide,
fulminate of mercury, smokeless powder, blasting caps and detonating
primers.
2.
Class B, low explosives: Those explosives not otherwise specified
herein as Class A explosives, including, but not limited to, explosives
presenting a flammable hazard such as propellant explosives and photographic
flash powder.
PERSON
Any individual, firm, copartnership, corporation, company,
association, joint stock association, and including any trustee, receiver,
assignee or personal representative thereof.
PYROTECHNICS
Means and includes any combustible or explosive composition
or manufactured articles designated and prepared for the purpose of
producing audible or visual effects which are commonly referred to
as "fireworks."
SCALED DISTANCE
The actual distance (in feet) to the nearest structure, divided
by the square root of the maximum explosive weight (in pounds) per
eight-millisecond (or greater) delay. If delay intervals less than
eight (8) milliseconds are employed or if instantaneous blasting is
employed, scaled distance shall be computed by dividing the actual
distance (in feet) by the square root of the total explosive weight
in pounds.
SINGULAR AND PLURAL
Words used in the singular number shall include the plural
and in the plural the singular.
[Ord. No. 4685 §1, 12-21-2015]
This Article shall apply to the manufacture, storage, sale,
transportation or use of explosives and blasting agents in the City.
It shall not apply to the discharge of small arms ammunition when
discharged in connection with hunting or target shooting or other
lawful uses connected with firearms.
[Ord. No. 4685 §1, 12-21-2015]
Nothing contained in this Article shall be construed as applying
to the regular military or naval forces of the United States, the
duly authorized militia of the State, the Police or Fire Departments
or to regular employees of the City in the proper performance of their
official duties.
[Ord. No. 4685 §1, 12-21-2015]
A. It shall be unlawful for any person to possess, store, stock or hold
for resale any amount of explosives, blasting agents or blasting caps
unless such person has first obtained a written permit therefor from
the Director as hereinafter provided, except for the following items
and amounts:
1.
Thirty (30) pounds of smokeless powder and one thousand (1,000)
small arms primers for hand loading of small arms ammunition.
2.
Thirty (30) pounds of explosives or blasting agents in industrial
research laboratories and laboratories of technical institutes, colleges,
universities and similar institutions.
3.
Pyrotechnics which shall be governed by other ordinance of the
City.
[Ord. No. 4685 §1, 12-21-2015]
A. Application for such permit to possess, store, stock or hold for sale those items specified in Section
500.1220 hereof shall be made to the Director at the courthouse on forms provided and shall contain the following information:
6.
Experience in the use of explosives and such other information
relative thereto as the Director may prescribe or require.
7.
Maximum amount of each kind of explosives, blasting agents or
blasting caps applicant intends to store or stock at any one time
and the location and Type of construction of the magazine or storage
place of same.
[Ord. No. 4685 §1, 12-21-2015]
A. A person shall be entitled to a permit to store or stock explosives
or blasting agents in the City who has met the following requirements:
1.
Filed an application as provided in Section
500.1220 hereof.
2.
Secured whatever construction, occupancy or other permits which
the applicant may otherwise be required by law to obtain.
3.
Obtained a proper storage facility for the storage of such explosives
as the same may be required by this Article.
[Ord. No. 4685 §1, 12-21-2015]
A. No person shall store any explosive materials in a manner not in
conformity to this Article.
B. Any change, addition, or modification to an approved storage facility shall not be made unless authorized by a new permit under Section
500.1230.
[Ord. No. 4685 §1, 12-21-2015]
A. For purposes of this Article, there shall be five (5) Types of storage
facilities. These Types, together with the classes of explosive materials
which shall be stored therein, are as follows:
1.
Type 1 storage facilities. Permanent storage facilities for the storage of high explosives, subject to the limitations prescribed by Sections
500.1290 and
500.1360. Other classes may also be stored therein.
2.
Type 2 storage facilities. Portable indoor and outdoor storage facilities for the storage of high explosives, subject to the limitations prescribed by Sections
500.1290,
500.1310(A)(2) and
500.1360. Other classes may also be stored therein.
3.
Type 3 storage facilities. Portable outdoor facilities for the temporary storage of high explosives while attended (for example, a "day-box"), subject to the limitations prescribed by Sections
500.1290 and
500.1360. Other classes may also be stored therein.
4.
Type 4 storage facilities. Facilities for the storage of low explosives, subject to the limitations prescribed by Sections
500.1290(B)(2),
500.1330(A)(2) and
500.1360. Blasting agents may also be stored therein.
5.
Type 5 storage facilities. Facilities for the storage of blasting agents, subject to the limitations prescribed by Sections
500.1290(A) and (B)(2), and 1340(A)(2) and 500.1360.
[Ord. No. 4685 §1, 12-21-2015]
Any person storing explosive materials shall open and inspect
his storage facilities at intervals not greater than three (3) days
to determine whether the explosives therein are intact and to determine
whether there has been unauthorized entry or attempted entry into
the storage facilities or the unauthorized removal of facilities or
their contents.
[Ord. No. 4685 §1, 12-21-2015]
A. Records shall be kept of all Class A high explosives when such are
kept in or on any premises in the portions of the City covered by
this Article or when stored in facilities licensed under the terms
of this Article. Such records shall consist of:
1.
Quantities of all materials entering or leaving the facility.
2.
Dates and times of all material entering or leaving the facility
or premises.
3.
A description, brand name and serial number(s) of all involved
material.
4.
Names of the person(s) removing any involved material and the
reason for the removal.
5.
Any other information that the Director may require in a written
notification to the licensee or permittee.
B. Such written records shall be kept at or near the storage facility
and shall be available at all times to the Director or his agent.
[Ord. No. 4685 §1, 12-21-2015]
A. All explosive materials must be kept in storage facilities meeting
the standards prescribed by this Article unless they are:
1.
In the process of manufacture; or
2.
Being physically handled in the operating process of a licensee
or user; or
4.
Being transported to a place of storage or use by a permittee
or by a person who has lawfully acquired explosive materials in the
manner required by this Article.
[Ord. No. 4685 §1, 12-21-2015]
A. Except as otherwise provided in this Article, storage facilities
in which any explosive materials are stored shall be located at minimum
distances from inhabited buildings, passenger railways, public highways,
and from other storage facilities in which explosive materials are
stored as specified in the American Table of Distances (Appendix B), provided, that this table shall not apply to any indoor
storage facility. When a storage facility is not barricaded, the distances
shown in the American Table of Distances shall be doubled. For purposes
of this Subsection, a storage facility shall be deemed barricaded
when it is effectually screened from inhabited buildings, passenger
railways, public highways, and other storage facilities in which explosive
materials are stored either by a natural or artificial barricade of
such height that a straight line from the top of any side wall of
the storage facility to the eave line of such other inhabited building
or storage facility, or to a point twelve (12) feet above the center
of a passenger railway or public highway, will pass through such intervening
barricade.
B. If any two (2) or more storage facilities are separated from each
other by less than the distances specified in Appendix B, then such two (2) or more storage facilities, as a group,
shall be considered as one storage facility, and the total quantity
of explosive materials stored in such group shall be treated as if
stored in a single facility and shall comply with the minimum of distances
specified in Appendix B from other storage facilities, inhabited buildings,
passenger railways, and public highways.
1.
Storage facilities in which low explosives are stored shall
be located at minimum distances from inhabited buildings, passenger
railways, public highways, and from other storage facilities in which
explosive materials are stored as specified in the Table of distances
for storage of low explosives as set forth in 27 CFR 181.199, provided,
that this table shall not apply to any indoor storage facility. The
distances shown therein shall not be reduced by the presence of barricades.
2.
Ammonium nitrate and storage facilities in which blasting agents
are stored shall be located at minimum distances from storage facilities
containing high explosives or blasting agents as specified in the
Table of recommended separation distances of ammonium nitrate and
blasting agents from explosives or blasting agents as set forth in
27 CFR 181.200.
[Ord. No. 4685 §1, 12-21-2015]
A. A Type 1 storage facility shall be a permanent structure: a building,
an igloo or Army-type structure, a tunnel, or a dugout. It shall be
bullet-resistant, fire-resistant, weather-resistant, theft-resistant,
and well ventilated.
1.
Buildings. All building-type storage facilities
shall be constructed of masonry, wood, metal, or a combination of
these materials and shall have no openings except for entrances and
ventilation. Ground around such storage facilities shall slope away
for drainage.
a.
Masonry wall construction. Masonry wall construction
shall consist of brick, concrete, tile, cement block, or cinder block
and shall be not less than six (6) inches in thickness. Hollow masonry
units used in construction shall have all hollow spaces filled with
well-tamped coarse dry sand or weak concrete (a mixture of one (1)
part cement and eight (8) parts of sand with enough water to dampen
the mixture while tamping in place). Interior walls shall be covered
with a non-sparking material.
b.
Fabricated metal wall construction. Metal wall
construction shall consist of sectional sheets of steel or aluminum
not less than Number 14 gauge, securely fastened to a metal framework.
Such metal wall construction shall be either lined inside with brick
solid cement blocks, hardwood not less than four (4) inches in thickness,
or shall have at least a 6-inch sand fill between interior and exterior
walls. Interior walls shall be constructed of or covered with a non-sparking
material.
c.
Wood frame wall construction. The exterior
of outer wood walls shall be covered with iron or aluminum not less
than Number 26 gauge. An inner wall of non-sparking material shall
be constructed so as to provide a space of not less than six (6) inches
between the outer and inner walls, which space shall be filled with
coarse dry sand or weak concrete.
d.
Floors. Floors shall be constructed of a non-sparking
material and shall be strong enough to bear the weight of the maximum
quantity to be stored.
e.
Foundations. Foundations shall be constructed
of brick, concrete, cement block, stone, or wood posts. If piers or
posts are used, in lieu of a continuous foundation, the space under
the buildings shall be enclosed with metal.
f.
Roof. Except for buildings with fabricated
metal roofs, the outer roof shall be covered with no less than Number
26 gauge iron or aluminum fastened to seven-eighths-inch sheathing.
g.
Bullet-resistant ceilings or roofs. Where it
is possible for a bullet to be fired directly through the roof and
into the storage facility at such an angle that the bullet would strike
a point below the top of inner walls, storage facilities shall be
protected by one (1) of the following methods:
(1) A sand tray shall be located at the tops of inner
walls covering the entire ceiling area, except that necessary for
ventilation, lined with a layer of building paper, and filled with
not less than four (4) inches of coarse dry sand.
(2) A fabricated metal roof shall be constructed of
three-sixteenths-inch plate steel lined with four (4) inches of hardwood.
(For each additional one-sixteenth-inch of plate steel, the hardwood
lining may be decreased one (1) inch.)
h.
Doors. All doors shall be constructed of one-fourth-inch
plate steel and lined with two (2) inches of hardwood. Hinges and
hasps shall be attached to the doors by welding, riveting or bolting
(nuts on inside of door). They shall be installed in such a manner
that the hinges and hasps cannot be removed when the doors are closed
and locked.
i.
Locks. Each door shall be equipped with two
(2) mortise locks; or with two (2) padlocks fastened in separate hasps
and staples; or with a combination of mortise lock and a padlock;
or with a mortise lock that requires two (2) keys to open; or a three-point
lock. Locks shall be five- tumbler proof. All padlocks shall be protected
with one-fourth-inch steel caps constructed so as to prevent sawing
or lever action on the locks or hasps. All doors shall be kept locked
at all times, except during placement and removal of stocks of explosives,
or during repairs to storage facilities.
j.
Ventilation. Except at doorways, a two-inch
air space shall be left around ceilings and the perimeter of floors.
Foundation ventilators shall be not less than four (4) inches by six
(6) inches. Vents in the foundation, roof, or gables shall be screened
and offset.
k.
Exposed metal. No sparking metal construction
shall be exposed below the top of walls in the interior of storage
facilities, and all nails therein shall be blind-nailed or countersunk.
2.
Igloos, Army-type structures, tunnels, and dugouts. Igloo, Army-type tunnel, and dugout storage facilities shall be constructed of reinforced concrete, masonry, metal, or a combination of these materials. They shall have an earth mound covering of not less than twenty-four (24) inches on the top, sides and rear. Interior walls and floors shall be covered with a non-sparking material. Storage facilities of this Type shall also be constructed in conformity with the requirements of Subsection
(A)(1)(d) and
(h) through
(k) of this Section.
[Ord. No. 4685 §1, 12-21-2015]
A. A Type 2 storage facility shall be a box, a trailer, a semitrailer or other mobile facility. It shall be bullet-resistant, fire-resistant, weather-resistant, theft-resistant, and well ventilated. Except as provided in Subsection
(A)(3) of this Section, hinges and hasps shall be attached to the covers or doors in the manner prescribed in Section
500.1300(A)(1)(h), and the locking system shall be that prescribed in Section
500.1300(A)(1)(i).
1.
Outdoor storage facilities. Outdoor storage
facilities shall be at least one (1) cubic yard in size and supported
in such a manner so as to prevent direct contact with the ground.
The sides, bottoms, tops, and covers or doors shall be constructed
of one-fourth-inch steel and shall be lined with two (2) inches of
hardwood. Edges of metal covers shall overlap sides at least one (1)
inch. The ground around such storage facilities shall slope away for
drainage. When unattended, vehicular storage facilities shall have
wheels removed or shall be otherwise effectively immobilized by kingpin
locking devices or other methods approved by the Director.
2.
Indoor storage facilities. No indoor facility
for the storage of high explosives shall be located in a residence
or dwelling. When located in a warehouse, wholesale, or retail establishment,
such storage facilities shall be provided with substantial wheels
or casters to facilitate removal therefrom. No more than two (2) indoor
storage facilities shall be kept in any one (1) building. Two (2)
storage facilities may be kept in the same building only when one
(1) is used for the storage of blasting caps, squibs, or similar items
and the other facility is used for the storage of other high explosives.
Each storage facility shall be located on the floor nearest the ground
level and within ten (10) feet of an outside exit. Indoor storage
facilities within one (1) building shall be separated by a distance
of not less than ten (10) feet. No indoor storage facility shall contain
a quantity of high explosives in excess of fifty (50) pounds or more
than five thousand (5,000) blasting caps. Indoor facilities shall
be of wood or metal construction as prescribed in Subsection (A)(2)(a)
or (b) of this Section.
i.
Wood construction. Wood indoor storage facilities
shall have sides, bottoms, and covers or doors constructed of 2-inch
hardwood and shall be well braced at corners. They shall be covered
with sheet metal of not less than Number 20 gauge. Nails exposed to
the interior of such facilities shall be countersunk.
ii. Metal construction. Metal indoor
storage facilities shall have sides, bottoms, and covers or doors
constructed of Number 12 gauge metal and shall be lined inside with
a non-sparking material. Edges of metal covers shall overlap sides
at least one (1) inch.
3.
Cap boxes. Storage facilities for blasting
caps in quantities of one hundred (100) or less shall have sides,
bottoms, and covers constructed of Number 12 gauge metal and lined
with a non-sparking material. Hinges and hasps shall be attached thereto
by welding. A single five-tumbler proof lock shall be sufficient for
locking purposes.
[Ord. No. 4685 §1, 12-21-2015]
A Type 3 storage facility shall be a day-box or other portable facility. It shall be constructed in the same manner prescribed for Type 2 outdoor storage facilities in Section
500.1310(A)(1), except that it may be less than one cubic yard in size, and shall be bullet-resistant, fire-resistant, weather-resistant, theft-resistant, and well ventilated. Hinges, hasps, locks, and lock protection shall be in conformity with the requirements of Section
500.1300(A)(1)(h) and (i). The ground around such storage facilities shall slope away for drainage. No explosive materials shall be left in such facilities if unattended. The explosive materials contained therein must be removed to Type 1 or 2 storage facilities for unattended storage.
[Ord. No. 4685 §1, 12-21-2015]
A. A Type 4 storage facility may be a building, an igloo or Army-type structure, a tunnel, a dugout, a box, a trailer, or a semi-trailer or other mobile facility and shall be fire-resistant, weather-resistant, and theft-resistant. It shall be constructed of masonry, metal-covered wood, fabricated metal, or a combination of these materials. The walls and floors of such storage facilities shall be lined with a non-sparking material. The doors or covers shall be metal or solid wood covered with metal. The foundations, locks, lock protection, hinges, hasps, and interior shall be in conformity with the requirements of Section
500.1300(A)(1)(e), (h), (i) and (k).
1.
Outdoor storage facilities. The ground around
such storage facilities shall slope away for drainage. When unattended,
vehicular storage facilities shall have wheels removed or shall be
otherwise effectively immobilized by kingpin locking devices or other
methods approved by the Director.
2.
Indoor storage facilities. No indoor facility
for the storage of low explosives shall be located in a residence
or dwelling. When located in a warehouse, wholesale, or retail establishment,
such storage facilities shall be provided with substantial wheels
or casters to facilitate removal therefrom. No more than one indoor
storage facility shall be kept in any one building. It shall be located
on the floor nearest the ground level and within ten (10) feet of
an outside exit. No indoor storage facility shall contain a quantity
of low explosives in excess of fifty (50) pounds.
[Ord. No. 4685 §1, 12-21-2015]
A. A Type 5 storage facility may be a building, an igloo or Army-type structure, a tunnel, a dugout, a bin, a box, a trailer, or a semitrailer or other mobile facility and shall be theft-resistant. The doors or covers thereof shall be solid wood or metal. The hinges, hasps, locks, and lock protection shall be in conformity with the requirements of Section
500.1300(A)(1)(h) and (i).
1.
Outdoor storage facilities. The ground around
such storage facilities shall slope away for drainage. When unattended,
vehicular storage facilities shall have wheels removed or shall be
otherwise effectively immobilized by king-pin locking devices or other
methods approved by the Director.
2.
Indoor storage facilities. No indoor storage
facility for the storage of blasting agents shall be located in a
residence or dwelling.
[Ord. No. 4685 §1, 12-21-2015]
Smoking, matches, open flames, and spark-producing devices shall
not be permitted in, or within fifty (50) feet of, any outdoor storage
facility.
[Ord. No. 4685 §1, 12-21-2015]
Blasting caps shall not be stored with other explosive materials
in the same storage facility.
[Ord. No. 4685 §1, 12-21-2015]
A. Explosive materials within a storage facility shall not be placed
directly against interior walls. Any devices constructed or placed
within a storage facility shall not interfere with ventilation.
B. Containers of explosive materials shall be stored by being laid flat
with top sides up. Corresponding classes, grades, and brands shall
be stored together within a storage facility in such a manner that
class, grade, and brand marks are easily visible upon inspection.
Stocks of explosive materials shall be stored so as to be easily counted
and checked.
C. Except with respect to fiberboard containers, containers of explosive
materials shall not be unpacked or repacked inside a storage facility
or within fifty (50) feet thereof, and shall not be unpacked or repacked
in close proximity to other explosive materials. Containers of explosive
materials shall be securely closed while being stored.
D. Tools used for opening or closing containers of explosive materials
shall be of non-sparking materials, except that metal slitters may
be used for opening fiberboard containers. A wood wedge and a fiber,
rubber, or wooden mallet shall be used for opening or closing wood
containers of explosive materials. Metal tools other than non-sparking
transfer conveyors shall not be stored in any storage facility containing
high explosives.
[Ord. No. 4685 §1, 12-21-2015]
When explosives or blasting agents are brought into the City
by railroad or other conveyance or means of transportation, for delivery
to a consignee, the person in charge of such delivery for such railroad
or public conveyance shall notify the consignee immediately upon arrival
of such explosives at a railroad station or any other place customarily
used by public conveyance for receipt and delivery of shipments, and
if said consignee does not remove said explosives from said location
within twenty-four (24) hours after such notification, then the person
in charge of such railroad station or other conveyance shall immediately
notify the Director, and shall remove said explosives beyond the limits
of the City, or to a magazine authorized by the Director. The time
allowance may be extended by special written permission from the Director,
when the Director determines that conditions beyond the control of
the consignee prevent the consignee from complying with the provisions
of this Section.
[Ord. No. 4685 §1, 12-21-2015]
It shall be unlawful for any owner, consignee, agent or employee thereof, having been notified of the arrival of the shipment of explosives as provided in Section
500.1380 above, to fail to remove or cause the removal of said explosives within twenty-four (24) hours after receipt of said notice or by the time set by the Director, to some place meeting the requirements of this Article.
[Ord. No. 4685 §1, 12-21-2015]
A. Explosives shall not be transported through any prohibited vehicular
tunnel, subway or over any prohibited bridge, roadway or elevated
highway.
B. No person shall smoke, carry matches or any other flame-producing
device, or carry any firearms or loaded cartridges while in or near
a motor vehicle transporting explosives; or drive, load or unload
such vehicle in a careless or reckless manner.
C. Explosives shall not be carried or transported in or upon a public
conveyance or vehicle carrying passengers for hire.
D. Explosives may be loaded into and transported on any truck and a
full trailer attached thereto, provided that there shall be no more
than one truck and one trailer comprising the combination.
E. Explosives shall not be transferred from one vehicle to another within
the City without first informing the Director and the Police Department.
In the event of breakdown or collision, the Director and the Police
Department shall be promptly notified to help safeguard such emergencies.
Explosives shall be transferred from the disabled vehicle to another
only when proper and qualified supervision is provided.
F. It shall be unlawful for any person to transport, haul or otherwise
convey blasting caps on the streets and highways of the City on the
same vehicle with explosives except that not more than fifty (50)
pounds of explosives and not more than twenty-five (25) blasting caps
may be transported on the same vehicle if the blasting caps are transported
in a container approved by the Director.
[Ord. No. 4685 §1, 12-21-2015]
A. Vehicles used for transporting explosives shall be strong enough
to carry the load without difficulty and be in good mechanical condition.
If vehicles do not have a closed body, the body shall be covered with
a flame-proof and moisture-proof tarpaulin or other effective protection
against moisture and sparks. All vehicles used for the transportation
of explosives shall have tight floors and any exposed spark-producing
metal on the inside of the body shall be covered with wood or other
non-sparking materials to prevent contact with packages of explosives.
Packages of explosives shall not be loaded above the sides of an open-body
vehicle.
B. Every vehicle used for transporting explosives shall be marked or
placarded on both sides, front and rear with the word "Explosives"
in letters not less than three (3) inches in height in contrasting
and clearly readable colors. In addition to such marking or placarding,
the vehicle may display, in such a manner that it will be readily
visible from all directions, a red flag eighteen (18) inches by thirty
(30) inches, with the word "Explosives" painted, stamped or sewed
thereon in white letters at least six (6) inches in height.
C. Fire Extinguishers.
1.
Every motor vehicle used for transporting explosives shall be
equipped with one of the following minimum fire extinguishing units:
a.
One (1) 2A 40BC fire extinguishing unit; or
b.
Two (2) 2A 20BC fire extinguishing units.
2.
Only extinguishers listed or approved by Underwriters' Laboratories,
Inc., Underwriters' Laboratories of Canada, Factory Mutual Laboratories
or by some other nationally recognized fire equipment testing laboratory
shall be deemed suitable for use on explosive-carrying vehicles. Extinguishers
shall be filled and ready for immediate use and located near the driver's
seat. Extinguishers shall be examined periodically by a competent
person.
D. All motor vehicles used for transporting explosives shall meet the
following requirements for safe transportation of explosives:
1.
Fire extinguishers shall be filled and in working order.
2.
All electrical wiring shall be completely protected and securely
fastened to prevent short circuiting.
3.
Chassis, motor, pan and underside of body shall be reasonably
clean and free of excess oil and grease.
4.
Fuel tank and feed line shall be secure and have no leaks.
5.
Brakes, lights, horn, windshield wipers and steering apparatus
shall function properly.
6.
Tires shall be checked for proper inflation and defects.
7.
The vehicle shall be in proper condition in every other respect
and acceptable for handling explosives.
E. Vehicles transporting explosives shall only be driven by, and be
in charge of, a driver who is physically fit, careful, capable, reliable,
able to read and write the English language, and not addicted to the
use or under the influence of intoxicants or narcotics, and not less
than twenty-one (21) years of age. He shall be familiar with the traffic
regulations, State laws and the provisions of this Article.
F. Except under emergency conditions, no vehicle transporting explosives
shall be parked before reaching its destination, even though attended,
on any public street adjacent to, or in proximity to, any bridge,
tunnel, dwelling, building or place where people work, congregate
or assemble.
G. No spark-producing metal, spark-producing metal tools, oils, matches,
firearms, electric storage batteries, flammable substances, acids,
oxidizing materials or corrosive compounds shall be carried in the
body of any motor truck and/or vehicle transporting explosives.
H. Vehicles transporting explosives shall avoid congested areas and
heavy traffic. Where routes through congested areas have been designated,
such routes shall be followed.
I. Delivery shall only be made to authorized persons and/or into authorized
magazines or approved temporary storage or handling areas.
[Ord. No. 4685 §1, 12-21-2015]
A. It shall be unlawful, without first having received a permit from
the Director, to explode or cause to be exploded, any gunpowder, dynamite,
giant powder, gun cotton or other explosive for the purpose of blasting
out rock, gravel, earth or other like substance within the City.
B. No person shall use or detonate explosives unless he is in possession
of a valid license, obtained from the Director, to use explosives
for blasting purposes. This license shall be known as a blaster's
license. For the purpose of this Article, the Director is authorized
to publish qualifications necessary for an applicant to obtain a blaster's
license. Such qualifications shall take into consideration age, training,
education, and experience in the knowledge and use of explosives and
shall include a written examination. A license shall be issued by
the Director to any applicant meeting the requirements set forth by
the Director for such a license.
C. The handling of explosives may be performed by other employees, provided
the work is done under the direct supervision of the person holding
the permit to use explosives and providing such employees are at least
twenty-one (21) years of age.
D. The person possessing a valid blaster's license shall be in charge
of all blasting operations. If there is more than one person possessing
such a license on any one operation, one will be designated as being
blaster in charge and shall be responsible for the entire operation.
[Ord. No. 4685 §1, 12-21-2015]
A. Application for a permit to use explosives shall be made to the Director
at the courthouse on forms provided and shall contain the following
information:
6.
The location where the blasting is to be done, the Type of blasting
material to be used in each charge, the number and location of charges
and the manner in which the material is to be detonated.
7.
The time and date of blasting when requested by the Director.
8.
The name, age and address of the blaster or blasters who shall
be the person or persons who shall actually detonate or have actual
charge of the detonation of any explosive or blasting agent.
9.
Blaster's license number.
10.
When blasting operations are conducted on a continuous basis, such as quarry blasting and construction work, the Director may, in lieu of Subsection
(A)(6), above, direct that the applicant furnish the location where blasting is to be done, the Type of blasting material generally used, the approximate frequency of detonations based on past performance and the manner in which the explosives are to be detonated.
B. In addition to the above information, there shall be attached to
the application for a permit to blast, the following: A certificate
of liability insurance in the minimum amount of five hundred thousand
dollars ($500,000.00) for injury to persons and property resulting
from the blasting operations. Such insurance shall be carried in a
firm or corporation which has been duly licensed or permitted to carry
on such business in the State of Missouri and shall be kept and maintained
continuously in force and effect for the duration of the blasting
permit.
[Ord. No. 4685 §1, 12-21-2015]
A. All blasting operations within the City shall be conducted in strict
accordance with the following rules and regulations, and it shall
be unlawful for any person to fail to observe and follow said rules
and regulations when blasting. In the event there is a violation of
said rules and regulations, the Director shall have the power and
it shall be his duty to revoke the blasting permit issued in connection
with the operation, revoke the license of the blaster in charge, all
in accordance with the terms of this Article, and, in addition, the
violator or violators may be punished as otherwise provided by this
Article for violations thereof.
1.
Blasting operations shall be carried on with the smallest possible
number of persons present.
2.
All drill holes shall be of sufficient size so that the cartridges
of explosives can be easily inserted to the bottom of the hole without
forcing or ramming.
3.
Explosives should not be removed from the original wrapper before
being loaded into bore holes except when irregularities of the hole
make it impossible to load whole cartridges with safety or in block-holing
where small charges are desirable. This rule shall not apply to free
running explosives.
4.
Excessive ramming should be avoided in loading or tamping explosives
in a bore hole, and wooden tools only, with no exposed metal parts,
shall be used for this purpose. In tamping, only hardwood rods without
metal parts, other than non-ferrous metal ferrules for extending the
length thereof, shall be used.
5.
When loading free running or bulk explosives, a bronze, wooden
or heavy paper funnel should be used unless the explosives can be
poured directly from a container into the hole in such a manner as
to prevent scattering of loose explosives around the collar of the
hole.
6.
When priming with electric caps, said caps shall be tested with
a blasting galvanometer after being loaded but before the hole is
stemmed. Primers shall be made up just prior to loading. The cap must
be properly embedded in the cartridge and the primer seated in the
charge without rough handling.
7.
When firing with a blasting machine, the blasting machine shall
be located at a safe distance to be determined by the blaster.
8.
When firing by means of a blasting machine, the leading wires
shall be kept short-circuited until the shot is ready for firing and
shall not be connected to the blasting machine until immediately before
the time of firing and shall be disconnected from the blasting machine
and short-circuited immediately after firing.
9.
Electric detonators and blasting circuits shall be tested only
by means of a blasting galvanometer designed for this purpose.
10.
Before firing any blast, all means of access to the danger zone
(the extent of which shall be determined by the blaster, but in no
case to be closer to the explosion than the blaster himself), shall
be effectively guarded to exclude all unauthorized personnel. When
practical, the blaster shall then sound a warning of sufficient intensity
and duration to be distinctly audible to all persons within the danger
zone, and all such persons shall retire beyond the danger zone. The
danger zone shall then be examined by the blaster to make certain
that all persons have retired therefrom to a place of safety. No blast
shall be fired while any person is in the danger zone.
11.
When the point of explosion is within three hundred (300) feet
of a roadway, the blaster shall, just prior to the blast, designate
a sufficient number of employees of the operator, each carrying a
red warning flag, to stop all vehicular and pedestrian traffic on
each possible route of travel within three hundred and fifty (350)
feet of the point of explosion until the blast has been fired.
12.
No person shall return to the danger zone until permitted to
do so by the blaster as announced by audible or visual signal.
13.
Immediately following the blast the area shall be examined by
the blaster for evidence of misfired charges.
14.
All misfires shall be reported at once to the superintendent
or manager who shall then determine the safe and proper method of
disposal. The unexploded charge shall be detonated if such can be
accomplished without risk of injury to personnel or damage to property.
If repriming is necessary, any stemming present in the hole may be
removed by a jet of water. The jetting tool should be of non-sparking
metal, rubber or plastic. If electric blasting caps are used for in-the-hole
initiation, an air jet should not be used.
15.
Drilling in any hole that is known to contain or have contained
explosives is prohibited until complete neutralization is effected.
16.
A complete record shall be kept by the blaster showing all misfires
and method of disposal.
17.
In case a charge fires but does not bring down the burden, it
is permissible to reload the bore hole, if in suitable condition,
but only after the temperature of the hole has been reduced by water
or otherwise to not more than one hundred fifty degrees Fahrenheit
(150° F.).
18.
Each blast hole shall be stemmed to the collar or to a point
high enough to provide efficient confinement of the charge and to
minimize the chance of injury to personnel from flying material. Block
holes shall contain at least eighty-five percent (85%) of stemming
material. For toe holes, the collar stemming shall in no case be less
than one-third the depth of the hole.
19.
When electric blasting caps are transported in a motor vehicle
equipped with a radio transmitter, they shall either be in their original
package or stored in a closed metal box that is lined with a cushioning
material such as wood or sponge rubber. When the electric caps are
being placed into or removed from the box, the transmitter shall not
be used.
20.
Unless otherwise expressly authorized in writing by the Director,
all blasting operations shall be conducted at no less distance from
any fixed or mobile radio transmitter than indicated in the following
table:
|
Transmitter Power Output
(watts)
|
Minimum Distance From Blasting Operations Using Electric
Blasting Caps
(feet)
|
---|
|
5 to 25
|
100
|
|
25 to 50
|
150
|
|
50 to 100
|
220
|
|
100 to 250
|
350
|
|
250 to 500
|
450
|
|
500 to 1,000
|
650
|
|
1,000 to 2,500
|
1,000
|
|
2,500 to 5,000
|
1,500
|
|
5,000 to 10,000
|
2,200
|
|
10,000 to 25,000
|
3,500
|
|
25,000 to 50,000
|
5,000
|
|
50,000 to 100,000
|
7,000
|
|
When it can be demonstrated by means of approved tests that
electric blasting may be carried out at lesser distances from the
transmitter than required by the table shown, the Director may allow
a variation from the requirements of said table.
|
|
When blasting operations are located near highways or other
public ways, signs shall be erected at least five hundred (500) feet
from the blast areas reading: "BLAST AREA-SHUT OFF ALL TWO-WAY RADIOS."
The letters of these signs shall be not less than four inches in height
on a contrasting background.
|
21.
In no case shall drilling be conducted closer than twenty-five
(25) feet to a loaded hole or a hole that is being loaded.
22.
Holes shall be checked prior to loading to determine depth and
condition. Holes may be checked with a dolly or tamping block or by
visual inspection with the aid of a mirror. After any explosives have
been loaded, all measuring shall be done with a cloth tape or non-ferrous
measuring device and lead plumb bob, or a wooden tamping pole or wooden
dolly free of exposed metal parts.
23.
Under no circumstances shall the amount of explosives taken within three hundred (300) feet of a potential point of explosion exceed the amount estimated by the blaster as necessary for the blast. Such explosives shall be stacked in piles at least twenty-five (25) feet from the nearest holes being loaded and at such distances apart, as provided in Subsection
(A)(32), that any premature explosion will not be likely to propagate from one (1) pile to another.
24.
The explosives containers, if any, shall be opened at the pile
and carried up to the hole, one (1) case or unit at a time for immediate
loading or placed at a loading station not less than six (6) feet
from the hole except that not more than one hundred (100) pounds of
explosives shall be allowed at the loading station at any one time.
All empty explosives containers (boxes, bags, crates, etc.) shall
be properly disposed of, daily, in a safe manner.
25.
Explosives shall be distributed in such a manner that the distances
from storage piles to the allowable maximum quantity of one hundred
(100) pounds of explosives at the loading station or between such
one-hundred-pound loading station piles shall not be less than the
quantities shown in the following quantity-distance table:
|
Explosives
(pounds)
|
Distance Between Piles of Explosives
(feet)
|
---|
|
Up to 50
|
21
|
|
100
|
25
|
|
200
|
32
|
|
300
|
37
|
|
400
|
41
|
|
500
|
44
|
|
750
|
50
|
|
1,000
|
55
|
|
1,500
|
64
|
|
2,000
|
70
|
|
2,500
|
75
|
|
5,000
|
96
|
|
10,000
|
123
|
26.
Drill holes shall not be sprung when they are less than one
hundred (100) feet from the nearest hole containing explosives. Holes
that have been sprung shall not be charged with explosives until the
maximum temperature in any portion of such holes has been reduced
to one hundred fifty degrees Fahrenheit (150° F.). Where possible,
water is to be used for cooling purposes.
27.
When loading a blast primed with detonating fuse, the detonator
or detonators required for firing the blast shall not be brought within
fifty (50) feet of the hole area nor attached to the detonating fuse
until all persons, except the blaster and his assistants, have been
cleared from the danger zone.
28.
In all blasting where the firing of any one (1) hole is likely
to break into or damage another hole in the vicinity or where the
firing of any hole may propagate the charge in a loaded hole in the
vicinity, all holes which have been loaded shall be included and fired
in the blast.
29.
Water standing in blast holes should be bailed out, if possible,
or the holes shall be loaded with an explosive of adequate water resistance.
30.
Blasting crews shall consist of the minimum number of experienced
men to do the work in an efficient manner and should be organized
carefully and each man assigned to definite tasks to avoid confusion.
31.
A blast shall be planned before the loading is started. The
planned charge for each hole shall be recorded prior to the blast.
32.
The condition of each hole to be loaded and the amount, height,
and position of the explosives charge or charges placed in the hole
shall be recorded on a loading chart prior to the blast.
33.
Members of loading crews engaged in loading blast holes should
be prohibited from wearing hobnail or steel-plated shoes to avoid
striking sparks on rocks.
34.
Large dynamite cartridges may be dropped in blast holes only
when the hole is free from obstructions to the depth at which the
cartridge is to rest.
35.
Large dynamite cartridges shall not be dropped in blast holes
containing excessive water until the charge is above the water level.
36.
Large dynamite cartridges that have been wedged in a blast hole
shall not be tamped with a dolly. After pouring water into the hole,
attempts to dislodge or pierce them shall be made with a spear-shaped
wooden tamping block or a small-diameter wooden pole.
37.
Rough or ragged holes and holes partly closed by an obstruction
that cannot be readily removed shall be loaded with cartridged dynamite
lowered with a rope, with free running powder or dynamite cut in small
pieces.
38.
When loading a long line of holes with more than one (1) loading
crew, the crews shall be separated by the greatest practical distance
which can be maintained as the loading operations progress and which
is consistent with efficient operation and supervision of the crews.
Every effort shall be made to keep the loading crews a minimum of
twenty-five (25) feet apart and to prevent the simultaneous loading
of adjacent holes.
39.
Excessively large amounts of explosives shall not be delivered
to the loading area at one (1) time. If deliveries of explosives are
made by truck, the quantity permitted at or near the loading operations
shall be limited to one (1) truckload. Other trucks loaded with explosives
shall wait or be unloaded in separate safe places away from the loading
operations.
40.
Explosives should be delivered first to the holes farthest from
the truck to avoid driving or walking among piles of explosives.
41.
Explosives in excess of immediate requirements when removed
from the main storage magazine and delivered in the vicinity of a
blasting operation shall be stored in a Class II magazine.
42.
The required stemming or tamping material shall be placed by
each hole before the delivery of explosives to the holes is started.
Stemming material shall be screened or free from excessively coarse
pieces.
43.
Stemming shall be placed in each hole to avoid damage to the
detonating fuse or leg wires of electric detonators.
44.
A single hole or any number of holes in a row should not be
fired when adjacent to or near one (1) or more other holes which are
loaded and which are not intended to be fired.
45.
All detonating fuses shall be covered with adequate stemming
where physically possible to reduce noise.
46.
The detonating fuse shall extend from the hole a distance of
one (1) feet or two (2) feet more than sufficient to compensate for
any subsidence, should be drawn taut and made secure on the top where
it will not interfere with loading operations or come in contact with
explosives on the ground.
47.
The detonating fuse shall be checked each time before stemming
material is used to see that it has not been broken; if it has, it
shall be repaired before proceeding.
48.
When a detonating fuse is used, main or trunk line splices shall
be factory splices or tight square knots. No splices or knots shall
be used in the drill hole.
49.
All branch line connections and all connections in the main
line other than splices shall be tight and at right angles.
50.
The main or trunk line shall be laid out free of kinks or coils,
and all connections shall be inspected before firing the blast.
51.
When connecting an electric blasting cap to a detonating fuse,
a connector for the purpose shall be used in accordance with the Director's
instructions. The cap may also be securely taped to the detonating
fuse.
52.
Caps shall not be brought to the loading area nor attached to
the detonating fuse until all is in readiness to fire the blast.
53.
Plain detonating fuse may be used for trunk lines or in shallow
drill holes, but reinforced or wire protected Types shall be used
in deep or ragged holes.
54.
"Toe hole blasting" is defined as the removing of ledges or
high bottoms that remain after a main or primary shot or blast using
moderate quantities of explosives loaded in small diameter holes.
In toe hole blasting, the charge of explosives shall be pushed to
the end of the hole with a wooden pole using care not to block the
hole, or suitable free-running blasting agents may be blown into the
hole with an approved pneumatic loader.
55.
"Secondary blasting" is defined as the reduction of oversize
material by the use of explosives to facilitate shovel operations
or to be accompanied by the crusher. It shall include mud-capping
and blockholing. In secondary blasting, wherever practicable, oversize
fragments shall be reduced to shovel or crusher size by use of the
drop-ball method, except as otherwise directed by the Director.
56.
Charges of explosives shall be confined in all cases (drill
holes) by suitable, inert stemming material.
57.
No person, except the blaster and any others directly engaged
in loading block holes, shall be permitted within the immediate area
while loading is being performed. Loading of any block hole shall
be completed in one continuous operation, including insertion of the
primer and the stemming.
58.
Blast matting (which may include earth) shall be required when
blast operations and/or geological conditions create fly rock that
could damage or injure persons or property, or at the decision of
the Director.
59.
In all blasting operations, except as hereinafter otherwise
provided, the maximum peak particle velocity of any one (1) of three
(3) mutually perpendicular components of the ground motion in the
vertical and horizontal directions shall not exceed two (2) inches
per second.
60.
Instrumentation shall be in good operating condition and be
properly calibrated with a current (within one (1) year of date of
use) calibration sticker affixed to each instrument. If an instrument(s)
is found to be not operating properly or out of calibration, blasting
operations shall be halted until the appropriate repairs or recalibration
are performed or a proper instrument(s) is provided. The seismograph
operator shall be trained in the use of that instrument(s).
61.
Seismographic instrumentation shall be required on any blast
site where the nearest uncontrolled structure or public utility is
located within a scaled distance of sixty-five (65) (as defined in
Rule 69) or at the request of the Director. An "uncontrolled structure"
is defined as any occupied building not owned or controlled by the
explosives user. The seismograph shall be placed at or near the closest
uncontrolled structure(s).
62.
Blasting operations without instrumentation will be considered
as being within the limits set forth in this Subsection if at a specified
location on at least five (5) blasts instrumentation has shown that
the maximum peak particle velocity at the specified location is fifty
percent (50%) or less of the limit set forth in this Subsection, and
with written permission from the Director; provided, that for all
future blasts the scaled distance is equal to or greater than the
scaled distance for the instrumental blast. However, if a scaled distance
less than thirty-five (35) is employed, a seismograph is required
regardless of the seismic readings of previous blasts. "Scaled distance"
means the actual distance in feet divided by the square root of the
maximum explosive weight in pounds that is detonated per delay period
for delay intervals of eight (8) milliseconds or greater. If delay
intervals less than eight (8) milliseconds are employed or if instantaneous
blasting is employed, scaled distance shall be computed by dividing
the actual distance in feet by the square root of the total explosive
weight in pounds. When blasting operations are contemplated which
would result in ground vibrations that would have a particle velocity
of any one (1) of three (3) mutually perpendicular components in excess
of two (2) inches per second, blasting operations may proceed after
receiving written consent from the property owner or owners affected
and the Director.
63.
Airblast limitations and measurements.
a.
Airblast shall be controlled so that it does not exceed the
maximum limits specified below at any uncontrolled structure [as defined
in rule 68(A)].
|
Lower Frequency Limits of Measuring System, Hz (+ 3dB)
|
Maximum Level in dB
|
---|
|
0.1 Hz or lower — flat response
|
134 peak
|
|
2 Hz or lower — flat response
|
133 peak
|
|
6 Hz or lower — flat response
|
129 peak
|
|
C-weighted, slow response
|
105 peak dBc
|
b.
All measuring systems used shall have a flat frequency response
of at least 200 Hz at the upper end.
c.
The permittee may satisfy the provisions of this Section by
meeting any of the four (4) specifications in the chart in Rule 73
of this Section; provided, however, the 0.1 Hz or lower-flat response
or C-weighted slow response can only be used if approved by the Director.
64.
When blasting in the vicinity of uncontrolled structures [as
defined in Rule 59(A)] the explosives user will determine the structures
lying within a scaled distance of thirty-five (35). The distance will
be determined by the following:
|
D = 35 (W2)
|
---|
|
Where D is the distance limit and W is the maximum charge weight
per 8 ms delay interval. The explosives user will make a good faith
effort to contact the owners of structures within the distance limit
and offer to have a preblast inspection performed on their structures
at no cost to the owners.
|
[Ord. No. 4685 §1, 12-21-2015]
Unless otherwise set forth in this Article, blasting agents
shall be transported, stored and used in the same manner as explosives.
[Ord. No. 4685 §1, 12-21-2015]
A. Buildings or other facilities used for mixing blasting agents shall
be located, with respect to inhabited buildings, passenger railroads
and public highways, in accordance with the American Table of Distance
(Appendix B).
1.
Any oxidizer stored at a closer distance to the blasting agent storage area than as provided in Subsection
(A)(2) below shall be added to the quantity of blasting agents to calculate the total quantity involved for application of the aforementioned Table.
2.
Minimum intra-plant separation (distances between mixing units
and the oxidizer) storage areas and blasting agent storage areas shall
be determined by competent persons, and these distances shall be approved
by the Director.
[Ord. No. 4685 §1, 12-21-2015]
A. Buildings used for the mixing of blasting agents shall conform to
the requirements of this Section unless otherwise specifically approved
by the Director.
1.
Buildings should preferably be of noncombustible construction
or sheet metal on wood studs.
2.
The layout of the mixing building shall be such as to provide
physical separation between the finished product storage and the mixing
and packaging operation.
3.
Floors in storage areas and in the processing plant should be
of concrete. Isolated fuel storage shall be provided to avoid contact
between molten oxidizer and fuel in case of fire.
4.
The building shall be well ventilated.
5.
Heat shall be provided exclusively from a unit outside the building.
B. The design of the mixer should minimize the possibility of frictional
heating, compaction and, especially, confinement. Open mixers are
preferable to enclosed mixers. Bearings and gears should be protected
against the accumulation of oxidizer dust. All surfaces should be
accessible for cleaning. Mixing and packaging equipment should be
constructed of materials compatible with the fuel-oxidizer composition.
Mobile equipment, such as ready-mix concrete trucks, shall not be
used for blending fuels with oxidizers while in transit on public
highways. The provisions of this Section shall be considered when
determining blasting agent composition. The sensitivity of the blasting
agent shall be determined by means of a No. 8 test blasting cap at
regular intervals and after every change in ingredients or composition,
or as may be requested by the Director.
C. Oxidizers of small particle size, such as crushed prills or fines,
may be more sensitive and hazardous than the ordinary prills and should
be handled with greater care.
D. No liquid fuel with higher volatility than that of No. 2 diesel fuel
(minimum flash point of one hundred forty-five degrees Fahrenheit
(145° F.), ASTM closed-up procedure) shall be used.
E. Crude oil and crankcase oil should not be used because they may contain
light ends that offer increased vapor-explosion hazards or gritty
particles that tend to sensitize the resulting blasting agent.
F. If solid fuels are used, they shall be chosen so as to minimize dust-explosion
hazard.
G. Metal dusts (aluminum powder, etc.), peroxides, chlorates, or perchlorates
shall not be used unless such operations are conducted in a manner
approved by the Director.
H. Unusual compositions shall not be attempted except under the supervision
of competent personnel equipped to determine the overall hazard of
the resulting compositions.
I. All electrical switches, controls, motors and lights, if allocated
in the mixing room, should conform to the requirements of Article
502, Class II, Division 2 of the Electrical Code of the City; otherwise
they should be located outside the mixing room. The frame of the mixer
and all other equipment that may be used shall be electrically bonded
and provided with a continuous path to the ground.
J. Washdown facilities should be provided. An automatic water-deluge
system with adequate capacity is recommended to protect mixers and
the finished-explosives storage area in the plant. Floors shall be
constructed so as to eliminate open floor drains and piping into which
molten materials could flow and be confined in case of fire. The floors
and equipment of the mixing and packaging room shall be washed down
frequently to prevent accumulation of oxidizers or fuels and other
sensitizers. The entire mixing and packaging plant shall be washed
down periodically to prevent excessive accumulation of dust.
K. Smoking or open flames shall not be permitted in or within fifty
(50) feet of any building or facility used for the mixing of blasting
agents.
L. Empty oxidizer bags shall be disposed of daily in a safe manner.
M. Not more than one (1) day's production of blasting agents or the
limit determined by the American Table of Distances (Appendix B), whichever is less, shall be permitted in or near the mixing
and packaging plant or area. Larger quantities shall be stored in
separate warehouses or magazines.
[Ord. No. 4685 §1, 12-21-2015]
A. When blasting agents are transported in the same vehicle with explosives, all of the requirements of Section
500.1400 of this Article shall be complied with.
B. Vehicles transporting blasting agents shall only be driven by and
be in charge of a driver at least twenty-one (21) years of age who
is capable, careful, reliable and in possession of a valid motor vehicle
operator's license. Such a person shall also be familiar with the
State vehicle and traffic laws.
C. No sparking metal, sparking metal tools, oils, matches, firearms,
acids or other corrosive liquids shall be carried in the bed or body
of any vehicle containing blasting agents.
D. No person shall be permitted to ride upon, drive, load or unload
a vehicle containing blasting agents while smoking or under the influence
of intoxicants or narcotics.
E. It is prohibited for any person to transport or carry any blasting
agents upon any public vehicle carrying passengers for hire.
F. Vehicles transporting blasting agents shall be in safe operating
condition at all times.
G. When offering blasting agents for transportation on City roads and
highways, they shall be packaged in a manner to render them safe for
transportation and handling and marked or labeled so as to be readily
identifiable.
[Ord. No. 4685 §1, 12-21-2015]
Persons using blasting agents shall comply with all of the applicable
provisions of this Article for the use of explosives.
[Ord. No. 4685 §1, 12-21-2015]
A. A record known as a "log" shall be kept for every primary blast in
an approved manner and for such other blasting as the Director may
require.
B. A blasting record, known as a "log," shall be kept on the site of
any blasting operations. This log shall be made available to the Director
or his authorized agents upon demand. This record shall be maintained
available for inspection for a period of six (6) months after such
blasting operations are completed.
C. Minimum recorded data shall be as follows:
1.
Plan of the involved portion of the blasting site showing location
of holes and spacing of holes.
2.
A cross-section of each hole showing overburden; burden at top
of face and toe; height of face; depth of hole; kind and quantity
of explosives, including distribution of explosives load as deck charges,
or otherwise as appropriate; length and kind of stemming material.
3.
Drilling record showing unusual joint or seam conditions in
the rock.
4.
Amount of explosives used (weight).
5.
Kind of blasting caps, distribution of instantaneous or short-period
delay blasting caps, or both; delay interval used; order of firing
by switch.
6.
Comments by blaster in charge regarding character of breakage;
height of breakage; length of throw; effectiveness of shot; unusual
results of effects.
7.
Weather conditions, including direction and approximate velocity
of wind; atmospheric temperature; relative humidity; cloud conditions.
8.
Date and time of firing of blast.
9.
Name of person in responsible charge of loading and firing;
blaster's permit number.
10.
Name and location of blasting site.
11.
Signature and title of person making report.
D. Any falsification, alterations or misrepresentation of any records
of blasting operations will be cause for suspension or revocation
of blasting permits and blaster's license.
[Ord. No. 4685 §1, 12-21-2015]
The fee for an annual blaster's license shall be fifty dollars
($50.00). The fees for blasting and storage of explosives permits
required by this Article shall be as prescribed in Sections 1100.210,
1100.220 and 1100.230, SLCRO 1974, as amended.
[Ord. No. 4685 §1, 12-21-2015]
It shall be unlawful for any person to explode, or cause to
be exploded, any gunpowder, dynamite, giant powder, gun cotton or
other explosives as herein defined for any purpose during the hours
of 6:00 P.M. to 8:00 A.M., except that a special permit to use explosives
during the hours of 6:00 P.M. to 8:00 A.M. may be issued by the Director
when the Director determines that conditions beyond the control of
the person seeking a special permit prevent such person from using
explosives during regular hours permitted.
[Ord. No. 4685 §1, 12-21-2015]
A. Blaster's licenses shall expire at the expiration of twelve (12)
months from date of issuance, but may be renewed at the discretion
of the Director without written examination.
B. Permits to store explosives or blasting agents shall expire at the
expiration of twelve (12) months from date of issuance, or when location
of magazine is changed.
C. Permit to blast shall expire on the date specified on the permit
issued by the Director, but may be extended by the Director.
D. All permits and licenses issued pursuant to this Article may be suspended
by the Director for good cause shown as hereinafter provided.
[Ord. No. 4685 §1, 12-21-2015]
A. The Director or any authorized Police Officer may, at any reasonable
time, inspect premises, buildings and installations used for storage
or sale of explosives or blasting agents, or any premises on which
blasting operations are being conducted for the purpose of determining
whether the provisions of this Article are being complied with.
B. The Director or any authorized Police Officer may, during normal
business hours, enter and inspect the premises, including places of
storage, of any licensed importer, licensed manufacturer, licensed
manufacturer-limited, licensed dealer, or permittee for the purpose
of inspecting or examining any documents and records required to be
kept by such person by law and any explosive materials kept or stored
by such person.
C. Any person who shall hinder or obstruct the Director or any Police Officer in the performance of his official duties shall be guilty of a violation of the provisions of this Article and, upon conviction thereof, shall be punished as provided in Section
500.1630.
[Ord. No. 4685 §1, 12-21-2015]
The Director or any authorized Police Officer may inspect the
site of any accident or fire in which there is reason to believe any
explosive materials were involved. The Director or any authorized
Police Officer may, at any reasonable time, enter into or upon any
property where explosive materials have been used or are suspected
of having been used, or have been found in an otherwise unauthorized
location.
[Ord. No. 4685 §1, 12-21-2015]
A. If, upon inspection by the Director or his agents, a violation of
this Article is found to exist, the Director shall file with the person
holding the permit a notice citing the violation and ordering its
correction. If such order is not complied with within the time period
specified in the notice, which may require immediate compliance, the
Director may suspend any permit or license issued to the person involved.
Nothing herein relating to revocation of permits shall be construed
to abrogate or suspend any proceedings against or prosecution of the
violator which may be instituted against the violator under the provisions
of this Article.
B. Immediately after the suspension of the permit to store or to blast,
the Director shall give the permittee written notice of the complaint
or charge and shall fix the date for a hearing to be held within five
(5) days of said notice, at which hearing the permittee shall have
the right to counsel and to produce witnesses and other evidence in
his behalf. For the purpose of said hearing, the Director is empowered
to issue subpoenas and all necessary processes, administer oaths and
take testimony at said hearing. All evidence offered at the hearing
shall be preserved by the Director, and oral testimony shall be recorded
verbatim.
C. If the Director shall, after such hearing, decide that the operation
for which the permit was issued was in violation of any provision
of this Article, he may revoke any permit or license of the person
involved permanently or for such lesser period of time as he shall
determine.
[Ord. No. 4685 §1, 12-21-2015]
During such time as any provision herein shall conflict with
any State or Federal statute or regulation, such provision herein
conflicting shall be suspended.
[Ord. No. 4685 §1, 12-21-2015]
No person shall load, unload or otherwise handle explosives
in a reckless and wanton manner, thereby endangering the life, limb
or property of any person.
[Ord. No. 4685 §1, 12-21-2015]
No person shall, with the intent of depriving the owner of lawful
possession thereof, use, possess, receive, conceal, transport, sell
or dispose of any stolen explosive materials knowing or having reasonable
cause to believe such materials were stolen. (O. No. 2703)
[Ord. No. 4685 §1, 12-21-2015]
It shall be unlawful for any person to sell, vend, give away
or otherwise supply any explosive as defined herein in any quantity
to any person under the age of twenty-one (21) years.
[Ord. No. 4685 §1, 12-21-2015]
Any person who has knowledge of the theft or loss of any explosive
materials shall immediately report such theft or loss to the Director
and the Police Department.
[Ord. No. 4685 §1, 12-21-2015]
A. Every person who has a permit to store, stock or store for resale
explosives as defined herein shall be required to maintain a bound
ledger and shall record or cause to be recorded therein the following
information in connection with every sale, vending or other disbursement
of explosives:
B. Such record shall be open to inspection by the Director or his agent
during usual business hours. No licensed user of explosives or blasting
agents shall be allowed to resell explosives or blasting agents except
by the written authorization of the Director.
[Ord. No. 4685 §1, 12-21-2015]
Any person violating any of the provisions of this Article shall,
upon conviction thereof, be punished by a fine not to exceed five
hundred dollars ($500.00) or imprisoned not to exceed 1-year, or both,
and each such violation shall constitute a separate offense. In addition
to the penalties prescribed herein, the Board of Aldermen may take
such other action, either legal or equitable, that it deems necessary
in order to execute and enforce the provisions of this Article.
[Ord. No. 4685 §1, 12-21-2015]
A. Any applicant, permittee or other person aggrieved by any order of
the Director issued pursuant to this Article, except the revocation
of a permit which is covered elsewhere in this Article, may file an
appeal with the Director within ten (10) days of such order, and the
Director shall fix a time and place for hearing to be held not less
than five (5) days nor more than ten (10) days of the filing of appeal
at which hearing the permittee shall have the right to counsel and
to produce witnesses and other evidence in his behalf. For the purpose
of said hearing, the Director is empowered to issue subpoenas and
all necessary processes, administer oaths and take testimony at said
hearings. All evidence offered at the hearing shall be preserved by
the Director, and oral testimony shall be recorded verbatim.
B. The decision and action of the Director at the hearing to revoke
the permit shall be reviewable in a court of competent jurisdiction
by a writ of certiorari filed by the permittee so affected or by any
other person aggrieved by the action of the Director, within ten (10)
days after said decision in writing has been made and forwarded to
said permittee.