Provide one-half-inch expansion joints at sixty-foot intervals, at
the end of each pour, and at the beginning and end of all radii. One-half-inch
expansion joint material shall also separate curb from adjacent sidewalks,
poles, hydrants, walls and other permanent structures, except that
three-fourths-inch thick expansion joint material shall be provided
at storm inlets.