For any of the activities regulated by this chapter, the preliminary
or final approval of subdivision and/or land development plans, the
issuance of any building or occupancy permit, or the commencement
of any earth disturbance activity may not proceed until the property
owner or applicant or his/her agent has received written approval
of a drainage plan from the municipality, and obtained an NPDES permit
for stormwater discharges associated with construction activities,
if greater than one acre of land disturbance, from the Montgomery
County Conservation District and/or DEP, and an adequate erosion and
sediment control plan review by the Conservation District. The Borough
shall be provided with a copy of all outside agency permit applications
and final approval or permit.
The drainage plan shall consist of a general description of the project, including sequencing items described in §
408-17, calculations, maps, and plans. A note on the maps shall refer to the associated computations and erosion and sediment control plan by title and date. The cover sheet of the computations, erosion and sediment control plan, and post-construction stormwater management (PCSM) plan shall refer to the associated maps by title and date. All drainage plan materials shall be submitted to the municipality in a format that is clear, concise, legible, neat, and well-organized. If not, the drainage plan shall not be accepted for review and shall be returned to the applicant. The following items shall be included in the drainage plan:
A. General.
(1) General description of the project, including those areas described in §
408-17B.
(2) General description of proposed permanent stormwater management techniques,
including construction specifications of the materials to be used
for stormwater management facilities.
(3) Complete hydrologic, hydraulic, and structural computations for all
stormwater management facilities.
(4) An erosion and sediment control plan, including all reviews and letters
of adequacy from the Conservation District, as applicable.
(5) A general description of proposed non-point-source pollution controls.
(6) The drainage plan application (Appendix B).
(7) The development or construction schedule.
B. Maps. Map(s) of the project area shall be submitted on twenty-four-inch-by-thirty-six-inch
sheets and/or shall be prepared in a form that meets the requirements
for recording at the office of the Recorder of Deeds of Montgomery
County. If the SALDO has more-stringent criteria than this chapter,
then the more-stringent criteria shall apply. The contents of the
map(s) shall include, but not be limited to:
(1) The location of the project relative to highways, municipal boundaries,
or other identifiable landmarks.
(2) Existing contours at intervals of two feet. In areas of slopes greater
than 25%, five-foot contour intervals may be used.
(3) Existing streams, lakes, ponds, or other waters of the commonwealth
within the project area.
(4) Other physical features, including flood hazard boundaries, stream
buffers, existing drainagecourses, areas of natural vegetation to
be preserved, and the total extent of the upstream area draining through
the site.
(5) The locations of all existing and proposed utilities, sanitary sewers,
and water lines within 50 feet of property lines.
(6) An overlay showing soil names, boundaries and limitations (in tabular
format).
(7) Limits of earth disturbance, including the type and amount of impervious
area that would be added.
(8) Proposed structures, roads, paved areas, and buildings.
(9) Final contours at intervals of two feet. In areas of steep slopes
(greater than 25%), five-foot contour intervals may be used.
(10)
The name of the development, the name and address of the owner
of the property, and the name of the individual or firm preparing
the plan.
(12)
A graphic and written scale of one inch equals no more than
50 feet; for tracts of 20 acres or more, the scale shall be one inch
equals no more than 100 feet.
(14)
The total tract boundary and size, with distances marked to
the nearest foot and bearings to the nearest degree.
(15)
Existing and proposed land use(s).
(16)
A key map showing all existing man-made features beyond the
property boundary that would be affected by the project.
(17)
Location of all open channels, as well as indicating where they
are draining after they leave the site (storm sewer, defined drainage
swale, stream channel, waters of the commonwealth, etc.).
(18)
Overland drainage patterns and swales.
(19)
A fifteen-foot-wide access easement to all stormwater management
facilities that would provide ingress to and egress from a public
right-of-way.
(20)
The location of all erosion and sediment control facilities,
both temporary and permanent, and all post-construction stormwater
management facilities, BMPs, systems, etc.
(21)
A statement, signed by the applicant, acknowledging that any
revision to the approved plan must be approved by the municipality.
If more than one acre of land is disturbed, the Conservation District
and/or DEP must approve the plan. Any revision to the erosion and
sediment control plan must be submitted to the approving agency for
a determination of adequacy.
(22)
The following signature block for the design engineer:
"I, _____ (Design Engineer), on _____ (date of signature), hereby
certify that the stormwater management site plan meets all design
standards and criteria of the Royersford Borough Stormwater Management
Ordinance."
C. Supplemental information to be submitted to the municipality.
(1) A written description of the following information shall be submitted
by the applicant and shall include:
(a)
The overall stormwater management concept for the project designed in accordance with §
408-17.
(b)
Stormwater runoff computations as specified in this chapter.
(c)
Stormwater management techniques to be applied both during and
after development.
(d)
Expected project time schedule.
(e)
Development stages or project phases, if so proposed.
(f)
An operations and maintenance plan in accordance with §
408-34 of this chapter.
(g)
A determination of site conditions in accordance with the BMP
Manual. A detailed site evaluation shall be completed for projects
proposed in areas of carbonate geology or karst topography, and other
environmentally sensitive areas, such as brownfields.
(2) An erosion and sediment control plan.
(3) A description of the effect of the project (in terms of runoff volumes
and peak flows) on adjacent properties, aquatic features, and on any
existing municipal stormwater collection system that may receive runoff
from the project site.
(4) A declaration of adequacy and highway occupancy permit from the Pennsylvania
Department of Transportation (PennDOT) district office when utilization
of a PennDOT storm drainage system is proposed.
D. Stormwater management facilities.
(1) All PCSM BMP facilities must be located on a plan and described in
detail. The PCSM plan package should include, at a minimum, pre- and
post-drainage area plans, an overall PCSM plan, PCSM details sheets,
landscaping or conservation plans, etc.
(2) When infiltration measures such as seepage pits, beds, or trenches
are used, the locations of existing and proposed septic tanks, infiltration
areas and wells must be shown. Minimum setback distances should be
identified from water supply wells, septic areas, and any adjacent
or downgradient buildings and/or structures with below-grade floors
or inhabitable space. This shall be done on the proposed development
site and/or downgradient of the site.
(3) All calculations, assumptions, and criteria used in the design of
the stormwater management facilities must be shown.
The municipality shall require a complete drainage plan, as
specified in this chapter.
A. Proof of application or documentation of required permit(s) or approvals
for the permits listed below shall be part of the plan:
(1) NPDES permit for stormwater discharges from construction activities.
(2) DEP joint permit application.
(3) PennDOT highway occupancy permit and/or Royersford Borough road opening
permit, as applicable.
(4) Chapter 105 (Dam Safety and Waterway Management).
(5) Chapter 106 (Identified Floodplain Area Management).
(6) Any other permit under applicable state or federal regulations.
B. The plan shall be coordinated with the state and federal permit process
and the municipal SALDO review process.
C. For projects that require SALDO approval, the drainage plan shall
be submitted by the applicant as part of the preliminary plan submission
where applicable for the regulated activity.
D. For regulated activities that do not require SALDO approval, see §
408-24, General requirements.
E. Six copies of the drainage plan may be submitted to the Borough and
distributed as follows:
(1) Two copies to the municipality accompanied by the requisite municipal
review fee, as specified in this chapter.
(2) Two copies to the County Conservation District.
(3) One copy to the Municipal Engineer.
(4) One copy to the County Planning Commission/Department.
F. Any submissions to the agencies listed above that are found to be
incomplete shall not be accepted for review and shall be returned
to the applicant with a notification, in writing, of the specific
manner in which the submission is incomplete.
An inconsistent or noncompliant drainage plan may be resubmitted with the revisions addressing the Municipal Engineer's concerns documented in writing. It must be addressed to the Borough in accordance with §
408-26 of this chapter, distributed accordingly, and be subject to review as specified in §
408-27 of this chapter. The applicable municipal review and inspection fee must accompany a resubmission of an inconsistent or noncompliant drainage plan.