A code regulating the installation, maintenance, repair and
control of the plumbing of buildings, and the connection thereof with
outside sewers, regulating the practice of plumbing and the issuance
of licenses to practice plumbing, is hereby established pursuant to
the provisions of R.S. 26:3-69.
The code adopted by this chapter is described and commonly known
as the Plumbing Code of New Jersey (Revised 1964) as amended April
29, 1966.
Three copies of the Plumbing Code of New Jersey (Revised 1964),
and amendment thereto dated April 29, 1966, shall be on file in the
office of the borough clerk for the use and examination of the public.
The following parts of the plumbing code are hereby excepted
from the provisions of this chapter: Section E-1400, subsection 14.6,
Title - Board of Plumber Examiners. Section E-900, subsection 9-1.3(a)
and (b). Section 300, subsection 3.4(c).
In connection with the provisions of this chapter and the code
hereby established, the following fees shall be charged and received:
For the examination of any applicant for license as master plumber,
$50.00.
For the issuance and renewal of a license as a master plumber,
$25.00. For the filing of plans for a proposed plumbing work, $2.00.
For the issuance of a permit for a proposed plumbing construction
or alteration, $3.00 per fixture.
In addition to the $2.00 filing fee set forth in the third paragraph
of this section, a fee of $10.00 shall be charged for the issuance
of a permit for the installation of a sewer connection.
In addition to the $2.00 filing fee set forth in the third paragraph
of this section, a fee of $10.00 shall be charged for the issuance
of a permit for the installation of a water connection to the public
water system.
For each reinspection of plumbing work caused by failure of
licensee to provide the provisions of the code or permit issued, $10.00.
For reinspection not covered in the preceding paragraph, a fee
of $2.00 for each reinspection.
Building sewers and laterals shall be of cast iron, joint shall
be tight and root proof, joints shall be calked and poured with lead.
Cast iron soil pipe may be of the following:
Weight in Pounds per 5-ft. Length
Size in inches
|
Single Hub Pipe
|
Double Hub Pipe
|
---|
2
|
21
|
22
|
3
|
30
|
32
|
4
|
45
|
47
|
5
|
57
|
59
|
6
|
72
|
75
|
8
|
110
|
115
|
10
|
160
|
165
|
12
|
200
|
210
|
15
|
275
|
290
|
Drainage and venting may be 3 inches M copper inside of house
for main stack and vent.