[Ord. No. 897-19, 5-1-2019]
A. No permit for floodplain development shall be granted for new construction,
substantial improvements, and other improvements, including the placement
of manufactured homes, within any numbered or unnumbered A zones and
AE zones, unless the conditions of this Section are satisfied.
B. All areas identified as unnumbered A zones on the FIRM are subject
to inundation of the one-hundred-year flood; however, the base flood
elevation is not provided. Development within unnumbered A zones is
subject to all provisions of this Chapter. If Flood Insurance Study
data is not available, the community shall obtain, review, and reasonably
utilize any base flood elevation or floodway data currently available
from Federal, State, or other sources.
C. Until a floodway is designated, no new construction, substantial
improvements, or other development, including fill, shall be permitted
within any numbered A zone or AE zone on the FIRM, unless it is demonstrated
that the cumulative effect of the proposed development, when combined
with all other existing and anticipated development, will not increase
the water surface elevation of the base flood more than one (1) foot
at any point within the community.
D. All new construction, subdivision proposals, substantial improvements,
prefabricated structures, placement of manufactured homes, and other
developments shall require:
1.
Design or adequate anchorage to prevent flotation, collapse,
or lateral movement of the structure resulting from hydrodynamic and
hydrostatic loads, including the effects of buoyancy;
2.
Construction with materials resistant to flood damages;
3.
Utilization of methods and practices that minimize flood damages;
4.
All electrical, heating, ventilation, plumbing, air-conditioning
equipment, and other service facilities be designed and/or located
so as to prevent water from entering or accumulating within the components
during conditions of flooding;
5.
New or replacement water supply systems and/or sanitary sewage
systems be designed to minimize or eliminate infiltration of floodwaters
into the systems and discharges from the systems into floodwaters,
and on-site waste disposal systems be located so as to avoid impairment
or contamination; and
6.
Subdivision proposals and other proposed new development, including
manufactured home parks or subdivisions, located within special flood
hazard areas are required to assure that:
a.
All such proposals are consistent with the need to minimize
flood damage;
b.
All public utilities and facilities, such as sewer, gas, electrical,
and water systems are located and constructed to minimize or eliminate
flood damage;
c.
Adequate drainage is provided so as to reduce exposure to flood
hazards; and
d.
All proposals for development, including proposals for manufactured
home parks and subdivisions, of five (5) acres or fifty (50) lots,
whichever is lesser, include within such proposals base flood elevation
data.
E. Storage, Material, And Equipment.
1.
The storage or processing of materials within the special flood
hazard area that are in time of flooding buoyant, flammable, explosive,
or could be injurious to human, animal, or plant life is prohibited.
2.
Storage of other material or equipment may be allowed if not
subject to major damage by floods, if firmly anchored to prevent flotation,
or if readily removable from the area within the time available after
a flood warning.
F. Accessory Structures. Structures used solely for parking and limited
storage purposes, not attached to any other structure on the site,
of limited investment value, and not larger than four hundred (400)
square feet, may be constructed at grade and wet-floodproofed, provided
there is no human habitation or occupancy of the structure; the structure
is of single-wall design; a variance has been granted from the standard
floodplain management requirements of this Chapter; and a floodplain
development permit has been issued.
G. Nonconforming Use. A structure, or the use of a structure or premises
that was lawful before the passage or amendment of this Chapter, but
which is not in conformity with the provisions of this Chapter, may
be continued subject to the following conditions:
1.
If such structure, use, or utility service is discontinued for
six (6) consecutive months, any future use of the building shall conform
to this Chapter.
2.
If any non-conforming use or structure is destroyed by any means,
including flood, it shall not be reconstructed if the cost is more
than fifty percent (50%) of the predamaged market value of the structure.
This limitation does not include the cost of any alteration to comply
with existing State or local health, sanitary, building, safety codes,
regulations or the cost of any alteration of a structure listed on
the National Register of Historic Places, the State Inventory of Historic
Places, or local inventory of historic places upon determination.
[Ord. No. 897-19, 5-1-2019]
A. In all areas identified as numbered and unnumbered A zones and AE zones, where base flood elevation data have been provided, as set forth in Article
IV, Section
415.150(B), the following provisions are required:
1.
Residential Construction. New construction or substantial improvement
of any residential structures, including manufactured homes, shall
have the lowest floor, including basement, elevated to three (3) feet
above base flood elevation.
2.
Non-Residential Construction. New construction or substantial improvement of any commercial, industrial, or other non-residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated to three (3) feet above the base flood elevation or, together with attendant utility and sanitary facilities, be floodproofed so that below the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall certify that the standards of this Subsection are satisfied. Such certification shall be provided to the Floodplain Administrator as set forth in Article
III, Section
415.130(A)(9).
3.
Require, for all new construction and substantial improvements,
that fully enclosed areas below the lowest floor used solely for parking
of vehicles, building access, or storage in an area other than a basement
and that are subject to flooding shall be designed to automatically
equalize hydrostatic flood forces on exterior walls by allowing for
the entry and exit of floodwaters. Designs for meeting this requirement
must either be certified by a registered professional engineer or
architect or meet or exceed the following minimum criteria:
a.
A minimum of two (2) openings having a total net area of not
less than one (1) square inch for every square foot of enclosed area
subject to flooding shall be provided; and
b.
The bottom of all openings shall be no higher than one (1) foot
above grade. Openings may be equipped with screens, louvers, valves,
or other coverings or devices, provided that they permit the automatic
entry and exit of floodwaters.
[Ord. No. 897-19, 5-1-2019]
A. All manufactured homes to be placed within all unnumbered and numbered
A zones and AE zones on the community's FIRM shall be required
to be installed using methods and practices that minimize flood damage.
For the purposes of this requirement, manufactured homes must be elevated
and anchored to resist flotation, collapse, or lateral movement. Methods
of anchoring may include, but are not limited to, use of over-the-top
or frame ties to ground anchors.
B. Require manufactured homes that are placed or substantially improved
within unnumbered or numbered A zones and AE zones, on the community's
FIRM on sites outside of a manufactured home park or subdivision;
in a new manufactured home park or subdivision; in an expansion to
an existing manufactured home park or subdivision; or in an existing
manufactured home park or subdivision on which a manufactured home
has incurred substantial damage as the result of a flood, be elevated
on a permanent foundation such that the lowest floor of the manufactured
home is elevated to three (3) feet above the base flood elevation
and be securely attached to an adequately anchored foundation system
to resist flotation, collapse, and lateral movement.
C. Require that manufactured homes to be placed or substantially improved on sites in an existing manufactured home park or subdivision within all unnumbered and numbered A zones and AE zones, on the community's FIRM, that are not subject to the provisions of Article
IV, Section 415.130(2) of this Chapter, be elevated so that either:
1.
The lowest floor of the manufactured home is at three (3) feet
above the base flood level; or
2.
The manufactured home chassis is supported by reinforced piers
or other foundation elements of at least equivalent strength that
are no less than thirty-six (36) inches in height above grade and
securely attached to an adequately anchored foundation system to resist
flotation, collapse, and lateral movement.
[Ord. No. 897-19, 5-1-2019]
A. Located within areas of special flood hazard established in Article
II, Section
415.040 are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters that carry debris and potential projectiles, the following provisions shall apply:
1.
The community shall select and adopt a regulatory floodway based
on the principle that the area chosen for the regulatory floodway
must be designed to carry the waters of the base flood without increasing
the water surface elevation of that flood more than one (1) foot at
any point.
2.
The community shall prohibit any encroachments, including fill,
new construction, substantial- improvements, and other development
within the adopted regulatory floodway unless it has been demonstrated
through hydrologic and hydraulic analyses performed in accordance
with standard engineering practice that the proposed encroachment
would not result in any increase in flood levels within the community
during the occurrence of the base flood discharge.
3.
If Article
IV, Section
415.180(A)(2) is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of Article
IV.
4.
In unnumbered A zones, the community shall obtain, review, and reasonably utilize any base flood elevation or floodway data currently available from Federal, State, or other sources as set forth in Article
IV, Section 415.150(B)2.
[Ord. No. 897-19, 5-1-2019]
A. Require that recreational vehicles placed on sites within all unnumbered
and numbered A zones and AE zones on the community's FIRM either:
1.
Be on the site for fewer than one hundred eighty (180) consecutive
days;
2.
Be fully licensed and ready for highway use*; or
3.
Meets the permitting, elevation, and the anchoring requirements
for manufactured homes of this Chapter.
*A recreational vehicle is ready for highway use if it is on
its wheels or jacking system, is attached to the site only by quick-disconnect-type
utilities and security devices and has no permanently attached additions.
|