The general requirements of this article apply to all development proposed within all special flood hazard areas identified in §
117-5 of this chapter.
New buildings and structures (including the placement and replacement
of manufactured homes) and substantial improvement of existing structures
(including manufactured homes) that are located, in whole or in part,
in any special flood hazard area shall:
A. Be designed (or modified) and constructed to safely support flood
loads. The construction shall provide a complete load path capable
of transferring all loads from their point of origin through the load-resisting
elements to the foundation. Structures shall be designed, connected,
and anchored to resist flotation, collapse, or permanent lateral movement
due to structural loads and stresses, including hydrodynamic and hydrostatic
loads and the effects of buoyancy, from flooding equal to the flood
protection elevation or the elevation required by this chapter or
the building code, whichever is higher.
B. Be constructed by methods and practices that minimize flood damage.
C. Use flood damage-resistant materials below the elevation of the lowest floor required in §
117-34A or
117-35A of this chapter (for A Zones) or §
117-40B of this chapter (for V Zones and Coastal A Zones).
D. Have electrical systems, equipment and components, and mechanical, heating, ventilating, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment located at or above the elevation of the lowest floor required in §
117-34A or
117-35A of this chapter (for A Zones) or §
117-40B of this chapter (for V Zones and Coastal A Zones). Electrical wiring systems are permitted to be located below elevation of the lowest floor provided they conform to the provisions of the electrical part of the building code for wet locations. If replaced as part of a substantial improvement, electrical systems, equipment, and components, and heating, ventilation, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment shall meet the requirements of this section.
E. As an alternative to Subsection
D, electrical systems, equipment and components, and heating, ventilating, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment are permitted to be located below the elevation of the lowest floor provided they are designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to that elevation.
F. Have the electric panelboard elevated at least three feet above the
BFE.
G. If located in flood hazard areas (A Zones) that are not identified as Coastal A Zones and coastal high hazard areas (V Zones), comply with the specific requirements of Article
V of this chapter.
H. If located in Coastal A Zone, comply with the specific requirements
of:
(1) Article
VI of this chapter (new construction and placement of new manufactured homes); or
(2) Article
V of this chapter [substantial improvements (including repair of substantial damage) and replacement manufactured homes].
I. If located in coastal high hazard areas (V Zones), comply with the specific requirements of Article
VI of this chapter.
J. Comply with the requirements of the most restrictive designation
if located on a site that has more than one flood zone designation
(A Zone, designated floodway, Coastal A Zone, V Zone).
Repair, alteration, addition, rehabilitation, or other improvement
of historic structures shall be subject to the requirements of this
chapter if the proposed work is determined to be a substantial improvement,
unless a determination is made that the proposed work will not preclude
the structure's continued designation as a historic structure.
The Floodplain Administrator may require documentation of a structure's
continued eligibility and designation as a historic structure.
Recreational vehicles shall:
A. Meet the requirements for manufactured homes in §
117-25 of this chapter;
B. Be fully licensed and ready for highway use; or
C. Be on a site for less than 180 consecutive days.
Critical and essential facilities shall:
A. Not be located in coastal high hazard areas (V Zones), Coastal A
Zones, or floodways.
B. If located in flood hazard areas other than coastal high hazard areas,
Coastal A Zones, and floodways, be elevated to the higher of elevation
required by this chapter plus one foot, the elevation required by
the building code, or the elevation of the 0.2-percent chance (500-year)
flood.
In addition to the application requirements of §
117-15 of this chapter, applications for the placement or erection of temporary structures and the temporary storage of any goods, materials, and equipment, shall specify the duration of the temporary use. Temporary structures and temporary storage in floodways shall meet the limitations of §
117-33A of this chapter. In addition:
A. Temporary structures shall:
(1) Be designed and constructed to prevent flotation, collapse, or lateral
movement resulting from hydrodynamic loads and hydrostatic loads during
conditions of the base flood.
(2) Have electric service installed in compliance with the electric code;
and
(3) Comply with all other requirements of the applicable state and local
permit authorities.
B. Temporary storage shall not include hazardous materials.
Applications for functionally dependent uses that do not conform to the requirements of this chapter shall be approved only by variances issued pursuant to Article
VII of this chapter. If approved, functionally dependent uses shall be protected by methods that minimize flood damage during the base flood, including measures to allow floodwaters to enter and exit, use of flood damage-resistant materials, and elevation of electric service and equipment to the extent practical given the use of the building.