[R.O. 2016 § 500.340; Ord. No. 170-97 §§ 1
— 3, 12-9-1997; Ord. No. 535-04 § 7, 4-13-2004; Ord.
No. 756-07 § 7, 11-13-2007; Ord. No. 762-07 § 8, 12-11-2007; Ord. No. 1063-14 § 9, 2-11-2014]
A. The
2012 Edition of the International Residential Code, as published by
the International Code Council (ICC), including Appendixes A, B, C,
E, G, H, J, M, N, and P, is hereby adopted as the Residential Code
of the City of Park Hills, Missouri, for the control of buildings
and structures, as therein provided; and each and all of the regulations,
provisions, penalties, conditions and terms of the said 2012 International
Residential Code, are hereby referred to, adopted and made a part
hereof as if fully set out in this Article with the additions, insertions,
deletions and changes, if any, prescribed by this Code.
B. Appendix
QA, titled Tiny Homes, of the 2021 International Residential Code,
as published by the International Code Council (ICC), is hereby adopted
by the City of Park Hills, which same is attached to Ord. No. 1465-22,
held on file in the City offices and incorporated herein by this reference.
[Ord. No. 1465-22, 3-8-2022]
[R.O. 2016 § 500.350; Ord. No. 535-04 § 8, 4-13-2004; Ord.
No. 733-07 § 1, 6-12-2007; Ord. No. 756-07 § 8, 11-13-2007; Ord. No. 762-07 § 9, 12-11-2007; Ord. No. 879-10 § 2, 1-12-2010; Ord. No. 1017-13 §§ 3
— 4, 2-12-2013; Ord. No. 1063-14 § 9, 2-11-2014]
A. The following Sections of the 2012 International
Residential Code are hereby revised:
1.
In Section R101.1, insert "City of
Park Hills."
2.
Section R105.2, Building, Subsection
1 is amended to read:
1.
|
One-story detached accessory structures
used as tool and storage sheds, playhouses, and similar uses, provided
that the floor area does not exceed one hundred (100) square feet
in area.
|
3.
In Section R105.2, Building, Subsections
2 and 10 are deleted in their entirety.
4.
Section R108.6 is amended to read:
Any person who commences work requiring
a permit on a building, structure, electrical, gas, mechanical or
plumbing system before obtaining the necessary permits shall be subject
to a fee of double the original permit fee in addition to the required
permit fees.
5.
In Section R112, replace "Board of
Appeals" with "Board of Adjustment."
6.
In Table R301.2(1), insert the following
values:
a.
|
Ground Snow Load: 20 psf.
|
b.
|
Wind Speed: 90 mph.
|
c.
|
Topographic Effects: No.
|
d.
|
Seismic Design Category: C.
|
e.
|
Weathering: Severe.
|
f.
|
Frost line depth: 30 inches.
|
g.
|
Termite: Slight to moderate.
|
h.
|
Winter Design Temp: 10° F.
|
i.
|
Ice Barrier Underlayment Required:
No.
|
j.
|
Flood Hazards:
|
|
(1)
|
June 16, 2011.
|
|
(2)
|
FIRM June 16, 2011.
|
k.
|
Air Freezing Index: 750.
|
l.
|
Mean Annual Temperature: 55°
F.
|
7.
Delete Section R312.2 in its entirety.
8.
Delete Section R313.2 and replace
with the following:
R313.2 Builder to offer automatic
fire sprinkler systems. A builder of single-family dwellings
or residences or multifamily dwellings of four (4) or fewer units
shall offer to any purchaser on or before the time of entering into
the purchase contract the option, at the purchaser's cost, to install
or equip fire sprinklers in the dwelling, residence or unit.
9.
Delete Section 4002.14 in its entirety.