R-1
|
Lake Drive Residence District No. 1
|
R-2
|
Lake Drive Residence District No. 2
|
R-3
|
Lake Drive Residence District No. 3
|
R-4
|
Lake Drive Residence District No. 4
|
R-5
|
Single-Household Residence District No. 1
|
R-6
|
One- and Two-Household Residence District No. 1
|
R-7
|
Townhouse Residence District
|
R-8
|
Estabrook Homes Residential District
|
R-9
|
Apartment House District No. 1
|
R-10
|
Apartment House District No. 2
|
P-1
|
Civic and Institutional District
|
P-3
|
Park Preservation District
|
PDD
|
Planned Development District Overlay
|
MX1
|
Mixed-Use Storefront 1
|
MX2
|
Mixed-Use Storefront 2
|
CX
|
Commercial Storefront Mix
|
GX1
|
General Residential-Office Mix 1
|
GX2
|
General Residential-Office Mix 2
|
GX3
|
General Residential-Office Mix 3
|
RX
|
Residential Mix
|
Table 535-22-1
Commercial and Mixed-Use Districts
| |
---|---|
Symbol
|
District Name
|
MX1
|
Mixed-Use Storefront 1
|
MX2
|
Mixed-Use Storefront 2
|
CX
|
Commercial Storefront Mix
|
GX1
|
General Residential-Office Mix 1
|
GX2
|
General Residential-Office Mix 2
|
GX3
|
General Residential-Office Mix 3
|
RX
|
Residential Mix
|
Link
|
Subsection Title
|
---|---|
Building siting
| |
Parking and accessory structures
| |
Height
| |
Roofs
| |
Primary and non-primary facades
| |
Supplemental regulations
|
Storefront Building Siting
| ||||
---|---|---|---|---|
Districts
| ||||
Regulation
|
MX
|
CX
|
Additional/References
| |
1 |
Lot Width (feet)
|
35
|
35
| |
2 |
Primary Street Wall (minimum)
|
80%
|
65%
|
Through-lots addressed per § 535-22D(7).
See § 535-22I(3) for measuring.
|
Primary Street Wall Variation
|
See § 535-22E(9)(a) for courtyard, outdoor plaza requirement on primary street walls over 120 feet wide.
| |||
3 |
Primary Street Build-To Zone
|
0 feet minimum
20 feet maximum
|
0 feet minimum
20 feet maximum
|
Minimum streetscape area required per § 535-22D(8).
See § 535-22I(4) for measuring.
Through-lots addressed per § 535-22D(7).
|
4 |
Non-Primary Street Build-To Zone
|
0 feet minimum
25 feet maximum
|
0 feet minimum
25 feet maximum
| |
5 |
Side Setback
|
0 feet minimum or, if set back at all, minimum 5 feet, except
if adjacent to a district other than MX or CX, minimum 5 feet
|
Buffer required adjacent to R Districts per § 535-22E(9).
| |
6 |
Rear Setback
|
Minimum 5 feet at alley; if no alley, minimum 20 feet
|
Storefront Building Parking Siting
| |||||
---|---|---|---|---|---|
Districts
| |||||
Regulation
|
MX
|
CX
|
Additional/References
| ||
7 |
Parking and Driveway Access Location
|
Alley; if no alley, 1 access off non-primary street; if no non-primary
street or alley, 1 access off primary street
|
See Article IX for parking.
| ||
Size
|
Maximum width of 22 feet at sidewalk
| ||||
8 |
Internal Parking Setback
|
20 feet minimum from primary facade above any basement
|
See § 535-23E(9) for garage door design regulations.
| ||
Internal Parking Door Location
|
Rear, side facade; if no alley exists, door may be located on
a non-primary street facade with an approved planning adjustment
| ||||
9 |
Surface Parking Location
|
Rear yard
|
Rear yard; limited side yard
|
See § 535-22I(7) for allowed limited side yard parking layout.
See § 535-24 for landscape buffers and parking lot landscaping.
| |
Street Setback
|
No closer to lot line than principal building
| ||||
Side and Rear Setback
|
0 feet minimum at alley; 3 feet minimum
|
0 feet minimum at alley; 3 feet minimum
| |||
10 |
Accessory Structure Location
|
See § 535-26 accessory structure regulations
|
See § 535-26 for additional accessory structure and use regulations.
| ||
Street Setback
|
No closer to lot line than principal building
| ||||
Side and Rear Setback
|
5 feet minimum
|
5 feet minimum
| |||
Key Accessory Structures
|
Key:
| ||||
Outbuildings and Garages
|
●
|
●
|
●
|
= Allowed
| |
○
|
= Requires a conditional use permit
| ||||
Drive-Through Facilities
|
○
|
●
| |||
Fuel Pumps
|
—
|
●
| |||
Outdoor Sales and Display
|
●
|
●
| |||
Parking Structure
|
●
|
●
|
Storefront Building Siting
| ||||
---|---|---|---|---|
Districts
| ||||
Regulation
|
MX
|
CX
|
Additional/References
| |
11 |
Height (stories)
|
2 minimum
In MX1: 4 maximum
In MX2: 5 maximum
|
2 minimum
5 maximum
|
See § 535-22E(9) for minimum story facade location.
Step-backs required adjacent to R Districts per § 535-22E(9).
|
12 |
Ground Story Height (feet)
|
12 minimum
16 maximum
Up to 20 maximum with an approved planning adjustment
|
Measured floor to floor. See § 535-22I(8) for measuring height.
| |
13 |
Upper-Story Height
|
9 feet minimum
12 feet maximum
|
9 feet minimum
12 feet maximum
| |
14 |
Stepped-Back Top Story
|
For all buildings over 3 stories and 120 feet in width along
the primary street, at least 50% of the top story primary street facade
must be stepped back a minimum of 7 feet from the ground story primary
facade.
|
Storefront Building Roofs
| ||||
---|---|---|---|---|
Districts
| ||||
Regulation
|
MX
|
CX
|
Additional/References
| |
15 |
Roof Types
|
Flat, parapet, pitched
|
See § 535-23B for roof types and tower regulations.
| |
Tower
|
Allowed
|
Storefront Building Facade
| ||||
---|---|---|---|---|
Districts
| ||||
Regulation
|
MX
|
CX
|
Additional/References
| |
16 |
Transparency: Ground Story on Primary Facades
|
65% minimum
|
70% minimum
|
See § 535-22I(9) for measuring transparency.
Blank wall segments apply.
See § 535-23F(4) for bird-safe glass treatments.
|
Measured between 2 feet and 10 feet from sidewalk grade
| ||||
No bays, sections 15 feet wide, or any rectangular areas greater
than 30% of a story's primary facade may be without transparency.
| ||||
Ground story transparency must extend a minimum of 30 feet around
the corner down any street side facades.
| ||||
17 |
Transparency: Upper Stories on Primary Facades
|
20% minimum
|
Measured per story, includes any half stories, visible basement, or towers with full height stories. See § 535-22I(9) for measuring transparency.
| |
No bays or sections 15 feet wide, or any rectangular areas greater
than 30% of a story's facade on a primary facade may be without
transparency.
| ||||
Transparency: Non-Primary Facades
|
20% minimum
| |||
18 |
Building Entrance Location
|
1 per every 60 feet of primary facade
|
See § 535-22I(10) for measuring building entrance location.
| |
19 |
Entrance Type
|
Storefront
|
See § 535-23C for entrance types.
| |
20 |
Ground Story Elevation
|
Within 24 inches of sidewalk elevation
| ||
21 |
Horizontal Divisions with Shadow Lines
|
Within 3 feet of the top of the first story
|
Horizontal shadow lines to run a minimum of 80% of length of facade. See § 535-6C for definition of "shadow lines."
| |
22 |
Vertical Divisions with Shadow Lines
|
1 per every 60 feet of ground story street facade
|
Link
|
Subsection Title
|
---|---|
Building siting
| |
Parking and accessory structures
| |
Height
| |
Roofs
| |
Primary and non-primary facades
| |
Supplemental regulations
|
Commercial Building Siting
| |||
---|---|---|---|
District
| |||
Regulation
|
CX
|
Additional/References
| |
1 |
Lot Width
|
40 feet minimum
| |
2 |
Primary Street Wall
|
50% minimum
| |
3 |
Primary Street Build-To Zone
|
10 feet minimum
35 feet maximum
|
Minimum streetscape area required per § 535-22D(8)
Outdoor plaza required per § 535-22F(9)
|
4 |
Non-Primary Street Build-To Zone
|
10 feet minimum
20 feet maximum
| |
5 |
Side Setback
|
5 feet minimum
|
Buffer required adjacent to R Districts per § 535-22F(9)
|
6 |
Rear Setback
|
Minimum 5 feet at alley; if no alley, minimum 20 feet
| |
7 |
Site Coverage
|
75% maximum
|
See § 535-22I(5) for measuring site coverage.
|
Commercial Building Parking Siting
| ||||
---|---|---|---|---|
District
| ||||
Regulation
|
CX
|
Additional/References
| ||
8 |
Parking and Driveway Access Location
|
1 access per 120 feet of each street frontage
|
See Article IX for parking.
| |
Size
|
Maximum width of 22 feet at sidewalk
| |||
9 |
Internal Parking Setback
|
20 feet minimum behind primary facade in rear of building above
any basement
|
See § 535-23E(9) for garage door design regulations.
| |
Internal Parking Door Location
|
Rear, side, non-primary facade
| |||
10 |
Surface Parking Location
|
Rear yard, side yard
|
Minimum primary street wall must be met for side yard parking.
See § 535-6C for definition of "yards."
See § 535-24 for landscape buffers and parking lot landscaping.
| |
Street Setback
|
No closer to lot line than principal building
| |||
Side and Rear Setback
|
5 feet minimum
| |||
11 |
Accessory Structure Location
|
See § 535-26 accessory structure regulations
|
See § 535-26 for additional accessory structure and use regulations.
| |
Street Setback
|
No closer to lot line than principal building
| |||
Side and Rear Setback
|
5 feet minimum; 15 feet minimum adjacent to R District
| |||
Key Accessory Structures
|
Key
| |||
Outbuildings and Garages
|
●
|
●
|
= Allowed
| |
Drive-Through Facilities
|
●
|
○
|
= Requires a conditional use permit
| |
Fuel Pumps
|
●
| |||
Outdoor Sales and Display
|
●
| |||
Parking Structure
|
—
|
Commercial Building Height
| |||
---|---|---|---|
District
| |||
Regulation
|
CX
|
Additional/References
| |
12 |
Height
|
1 story minimum
1 story maximum
|
See § 535-22I(8) for measuring height.
|
13 |
Story Height
|
10 feet minimum with pitched roof, 14 feet minimum with flat
or parapet roof 18 feet maximum
|
Commercial Building Roofs
| |||
---|---|---|---|
District
| |||
Regulation
|
CX
|
Additional/References
| |
14 |
Roof Types
|
Flat, parapet, pitched
|
See § 535-23B for roof types and tower regulations. See § 535-23B(5) for pitched roof on single-story building.
|
Tower
|
Allowed
|
Commercial Building Facade
| |||
---|---|---|---|
District
| |||
Regulation
|
CX
|
Additional/References
| |
15 |
Ground Story Transparency on Primary Facades
|
55% minimum
|
Ground story transparency measured between 2 feet and 10 feet from sidewalk grade. See § 535-22I(9) for measuring transparency.
Blank wall segments apply.
|
No bays, 15-foot-wide sections, or any rectangular areas greater
than 30% of a story's primary facade may be without transparency.
| |||
Ground story transparency must extend a minimum 30 feet around
the corner, down any street side facades.
| |||
Transparency: Non-Primary Facades
|
15% minimum
|
Measured per story, includes any towers with full-floor height. See § 535-22I(9) for measuring transparency.
| |
16 |
Building Entrance Location
|
1 per every 60 feet of primary facade
|
See § 535-22I(10) for measuring building entrance location.
|
17 |
Entrance Type
|
Storefront
|
See § 535-23C for entrance types.
|
18 |
Ground Story Elevation
|
Within 24 inches of sidewalk elevation
| |
Horizontal Divisions with Shadow Lines
|
—
|
See § 535-6C for definition of "shadow lines."
| |
19 |
Vertical Divisions with Shadow Lines
|
1 per every 60 feet of ground story street facade
|
Link
|
Subsection Title
|
---|---|
Building siting
| |
Parking and accessory structures
| |
Height
| |
Roofs
| |
Primary and non-primary facades
| |
Supplemental regulations
|
General Building Siting
| ||||
---|---|---|---|---|
Districts
| ||||
Regulation
|
GX
|
RX
|
Additional/References
| |
Multiple Principal Buildings
|
Allowed
|
Not allowed
|
Each building must meet the building type regulations with primary
street frontage.
| |
1 |
Lot Width
|
35 feet
|
35 feet
| |
2 |
Primary Street Wall
|
75% minimum
|
75% minimum
|
Through-lots addressed per § 535-22D(7). See § 535-22I(3) for measuring.
|
Primary Street Wall Variation
|
See § 535-22G(9)(a) for courtyard, outdoor plaza requirement on primary street walls over 120 feet wide.
| |||
3 |
Primary Street Build-To Zone
|
5 feet minimum
25 feet maximum
|
10 feet minimum
25 feet maximum
|
Contextual setbacks apply. See § 535-22I(4). See § 535-22D(8) minimum streetscape area
See § 535-24K for river shorelines setbacks along the Milwaukee River.
|
4 |
Non-Primary Street Build-To Zone
|
5 feet minimum
25 feet maximum
|
5 feet minimum
25 feet maximum
| |
5 |
Side Setback
|
Minimum 10 feet adjacent to R District; otherwise, minimum 5
feet
| ||
Between Buildings on a Lot
|
Minimum 10 feet
|
—
| ||
6 |
Rear Setback
|
Minimum 5 feet at alley; if no alley, minimum 20 feet.
|
See § 535-22G(9) for treatment adjacent to R Districts.
| |
Minimum 5 feet rear setback may be approved through a planning
exception when alley access exists along the side lot line.
| ||||
7 |
Site Coverage
|
80% maximum
|
70% maximum
|
See § 535-22I(5) for measuring site coverage.
|
General Building Parking Siting
| |||||
---|---|---|---|---|---|
Districts
| |||||
Regulation
|
GX
|
RX
|
Additional/References
| ||
8 |
Parking and Driveway Access Location
|
Alley; if no alley, 1 access off non-primary street; if no non-primary
street or alley, 1 access off primary street
|
See Article IX for parking.
| ||
Size
|
Maximum width of 22 feet at sidewalk
| ||||
9 |
Internal Parking Setback
|
20 feet minimum from primary facade above any basement
|
See § 535-23E(9) for garage door design regulations.
| ||
Internal Parking Door Location
|
Rear, interior side facades; if no alley, non-primary facade
may be approved with a planning adjustment
| ||||
10 |
Surface Parking Location
|
Rear yard
|
Rear yard
|
See § 535-24 for landscape buffers and parking lot landscaping.
| |
Street Setback
|
No closer to lot line than principal building
| ||||
Side and Rear Setback
|
3 feet minimum
|
5 feet minimum
| |||
Accessory Structure Location
|
See § 535-26 for accessory structure regulations.
|
See § 535-26 for additional accessory structure and use regulations.
| |||
Street Setback
|
No closer to lot line than principal building
| ||||
Side and Rear Setback
|
5 feet minimum
|
5 feet minimum
| |||
Key Accessory Structures
|
Key:
| ||||
Outbuildings and Garages
|
●
|
●
|
●
|
= Allowed
| |
Drive-Through Facilities
|
○
|
—
|
○
|
= Requires a conditional use permit
| |
Fuel Pumps
|
—
|
—
| |||
Outdoor Sales and Display
|
—
|
—
| |||
Parking Structure
|
●
|
○
|
General Building Height
| ||||
---|---|---|---|---|
Districts
| ||||
Regulation
|
GX
|
RX
|
Additional/References
| |
12 |
Height
|
2 stories minimum
GX1: 4.5 stories maximum
GX2: 5.5 stories maximum
GX3: 8.5 stories maximum
|
2 stories minimum
4.5 stories maximum
|
See § 535-22G(9) for minimum story facade location.
Step-backs required adjacent to R Districts per § 535-22G(9)
See § 535-22I(8) for measuring height.
|
13 |
Ground Story Height
|
10 feet minimum
GX1 and GX2: 14 feet maximum
GX3: 16 feet maximum
|
9 feet minimum
12 feet maximum
|
Measured floor to floor
|
14 |
All Other Stories Height
|
9 feet minimum
12 feet maximum
|
9 feet minimum
12 feet maximum
| |
15 |
Stepped-Back Top Story
|
All buildings in GX1 and GX2 over 3 stories and 120 feet in
width along the primary street: at least 50% of the top story primary
street facade must be stepped back a minimum of 7 feet from the ground
story primary facade.
|
General Building Roofs
| ||||
---|---|---|---|---|
Districts
| ||||
Regulation
|
GX
|
RX
|
Additional/References
| |
16 |
Roof Types
|
Flat, parapet, pitched
|
Flat, parapet, pitched
|
See § 535-23B for roof types and tower regulations.
|
Tower
|
Allowed
|
Allowed
|
General Building Facades
| ||||
---|---|---|---|---|
Districts
| ||||
Regulation
|
GX
|
RX
|
Additional/References
| |
Transparency:
| ||||
17 |
Primary Facades
Non-Primary Facades
|
20% minimum
18% minimum
|
20% minimum
18% minimum
|
Measured per story, includes any half stories, visible basements, or towers with full floor height. See § 535-22I(9) for measuring transparency.
Blank wall segments apply.
See § 535-23F(4) for bird-safe glass treatments.
|
No bays, 15-foot-wide sections, or any rectangular areas greater
than 30% of a story's primary facade may be without transparency.
| ||||
18 |
Building Entrance Location
|
1 per every 120 feet of primary facade
|
See § 535-22I(10) for measuring building entrance location.
| |
19 |
Entrance Type
|
Stoop
|
Stoop, porch
|
See § 535-23C for entrance types. See § 535-22I(8) for definition of "visible basement."
|
20 |
Ground Story Elevation
|
Between 18 inches and 30 inches above grade or between 30 inches
and 5 feet with a visible basement
| ||
21 |
Horizontal Divisions with Shadow Lines
|
1 within 3 feet of the top of any basement, first, or second
story
|
Horizontal shadow lines to run a minimum 80% of length of facade. See § 535-6C for definition of "shadow lines."
| |
22 |
Vertical Divisions with Shadow Lines
|
1 per every 120 feet of street facade
|
Link
|
Subsection Title
|
---|---|
Building siting
| |
Parking and accessory structures
| |
Height
| |
Roofs
| |
Primary and non-primary facades
| |
Supplemental regulations
|
Row Building Siting
| |||
---|---|---|---|
Districts
| |||
Regulation
|
GX, RX
|
Additional/References
| |
Configuration
|
Multiple side-by-side units sharing common side walls
| ||
Multiple Principal Buildings
|
Allowed
|
See § 535-22H(9) for multiple buildings on a lot.
| |
1 |
Lot Width
|
100 feet minimum
| |
2 |
Building Width per Street Frontage
|
3 units minimum
5 units maximum
|
See § 535-22H(9) for courtyards.
Measured in build-to zone along any street frontage
|
3 |
Primary Street Build-To Zone
|
15 feet minimum
35 feet maximum
|
See § 535-22D(8), Minimum streetscape area.
|
4 |
Non-Primary Street Setback
|
10 feet minimum
| |
5 |
Side Setback
Space Between Adjacent Buildings
|
7.5 feet minimum
15 feet minimum
| |
6 |
Rear Setback
|
5 feet minimum at alley; if no alley, 20 feet minimum
| |
7 |
Site Coverage
|
65% maximum
|
See § 535-22I(5) for measuring site coverage.
|
Row Building Parking Siting
| ||||
---|---|---|---|---|
Districts
| ||||
Regulation
|
GX, RX
|
Additional/References
| ||
8 |
Parking and Driveway Access Location
|
Alley; if no alley, 1 access off non-primary street; if no non-primary
street or alley, 1 access off primary street
|
See Article IX for parking.
| |
Size
|
Maximum 14 feet width at sidewalk
| |||
9 |
Internal Parking Setback
|
Minimum 12 feet behind primary facade above any basement
|
See supplemental regulations in § 535-22H(9) for garage door screening.
See § 535-23E(9) for garage door design regulations.
| |
Internal Parking Door Location
|
Rear; not visible from a primary street and screened from non-primary
streets
| |||
10 |
Parking Lot and Accessory Structure Location
|
Rear yard; see § 535-26 for accessory structure regulations.
|
See § 535-26 for additional accessory structure and use regulations.
| |
Street Side Setback
|
No closer to lot line than principal building
| |||
Side and Rear Setback
|
5 feet minimum
| |||
Key Accessory Structures
|
Key:
| |||
Outbuildings and Garages
|
●
|
●
|
= Allowed
| |
Drive-Through Facilities
|
—
|
○
|
= Requires a conditional use permit
| |
Fuel Pumps
|
—
| |||
Outdoor Sales and Display
|
—
| |||
Parking Structure
|
○
|
Row Building Height
| |||
---|---|---|---|
Districts
| |||
Regulation
|
GX, RX
|
Additional/References
| |
11 |
Height
|
2 stories minimum
3 stories maximum
|
See supplemental regulations on half stories in § 535-22H(9).
See § 535-22I(8) for measuring height.
|
12 |
Floor-to-Floor Height
|
9 feet minimum
11 feet maximum
|
Measured floor to floor
|
13 |
Height to Eaves (pitched roof)
|
20 feet maximum
|
Height to eaves is measured from the first floor to the bottom of the horizontal eave. See § 535-22I(8) for measuring height to eaves.
|
Row Building Roofs
| |||
---|---|---|---|
Districts
| |||
Regulation
|
GX, RX
|
Additional/References
| |
14 |
Roof Types
|
Pitched, flat, parapet
|
See § 535-23B for roof types and tower regulations.
|
Tower
|
Not allowed
|
Row Building Facades
| |||
---|---|---|---|
Districts
| |||
Regulation
|
GX, RX
|
Additional/References
| |
15 |
Transparency:
| ||
Primary Facades
Non-Primary Facades
|
20% minimum
15% minimum
|
Measured per story, including any half stories, visible basement,
or towers with full-floor height.
See § 535-22I(9) for measuring transparency.
Blank wall segments apply.
| |
No bays, 10-foot-wide sections, or any rectangular areas greater
than 30% of a story's primary facade may be without transparency.
| |||
16 |
Building Entrances Location
|
1 per unit on primary facade except 1 per every 3 units may
be located off a courtyard.
|
See § 535-22H(9) for courtyards
|
17 |
Entrance Type
|
Porch or stoop
|
See § 535-23C for entrance types.
|
18 |
Ground Story Elevation Above Grade
|
Between 18 inches and 30 inches above grade or between 30 inches
and 5 feet with a visible basement
| |
19 |
Horizontal Divisions with Shadow Lines
|
1 within 3 feet of the top of any basement, first, or second
story
|
See § 535-6C for definition of "shadow lines."
|
20 |
Vertical Divisions with Shadow Lines
|
1 for every 60 feet of facade on the ground story
|
Table 535-23-1
Tower Location, Quantity, and Spacing
| ||
Regulation
|
Street Facade Tower
|
Interior Building Tower
|
Location on building
|
Within 15 feet of any street facade
|
Minimum 30 feet from any street facade
|
Number allowed
|
2 per building
|
2 per building
|
Total of 4 per building
| ||
Spacing
|
120 feet minimum from other street-façade towers
|
60 feet minimum from any other tower
|
Table 535-23-2
Allowed Major Materials on Street and Primary Facades
| ||||||
---|---|---|---|---|---|---|
Building Type
| ||||||
Material (alphabetical)
|
Storefront Buildings
|
Commercial Building
|
General Buildings
|
Row Buildings
|
Illustration
| |
A |
Brick: full dimensional, economy, unit, face brick, unglazed,
no black
|
●
|
●
|
●
|
●
| |
B |
Concrete Masonry Units: architectural, minimum three-inch depth,
artisan stone look, varied sizes, (Echelon masonry or approved equal),
stone face, hewn stone, rock cut
|
●
|
●
|
●
|
●
| |
C |
Stone: natural, units
|
●
|
●
|
●
|
●
|
Table 535-23-4
Allowed Side and Rear Facade Materials
| ||||||
---|---|---|---|---|---|---|
All allowed major facade materials for street and primary facades
may be used for rear and side facades, unless otherwise listed as
prohibited in Table 535-23-6.
| ||||||
Building Types
| ||||||
Material (alphabetical)
|
Storefront Buildings
|
Commercial Building
|
General Buildings
|
Row Buildings
|
Illustration
| |
E |
Concrete Masonry Units: minimum 3-inch depth, split-faced, burnished/ground
face, glazed, or honed
|
●
|
●
|
●
|
●
| |
F |
Fiber Cement Board: finished panels, finished lap siding or
shingles
|
●
|
●
|
●
|
●
| |
H |
Metal, Architectural: articulated architectural panel, cladding
system (steel, titanium, zinc, corten steel)
|
●
|
●
|
●
|
●
| |
I |
Stucco: synthetic or with elastomeric finishes
|
●
|
●
|
●
|
—
| |
Third or higher stories only
|
Table 535-23-3
Allowed Minor Facade Materials
| |||||
---|---|---|---|---|---|
All allowed major facade materials for street and primary facades
may be used for minor facade materials, unless otherwise listed as
prohibited in Table 535-23-6.
| |||||
Material (alphabetical)
|
Allowed on Buildings in These Zones
|
Allowed Location
|
Maximum Amount on Allowed Facades
|
Illustration
| |
Brick: full dimensional, economy, unit, face brick, glazed,
black
|
All
|
All facades
|
35%
| ||
D |
Concrete Surfaces: finished, stained, painted, treated concrete
and precast panels
|
All
|
All facades, below ground floor only
|
10%
| |
E |
Concrete Masonry Units: minimum 3-inch depth, split-faced, burnished/ground
face, glazed, or honed
|
All
|
Street facades
|
20%
| |
F |
Fiber Cement Board: finished panels, finished lap siding or
shingles
|
All
|
All facades, stories above the ground story only
|
35%
| |
G |
Glass: curtain wall, no spandrel glass
|
All
|
All facades; see § 535-23F for bird-safe design
|
35%
| |
H |
Metal, Architectural: articulated architectural panel, cladding
system (steel, titanium, zinc, corten steel)
|
All
|
All facades, stories above the ground story only
|
35%
| |
Stucco: cement-based, 2- to 3-layer hard coat
|
All
|
All facades
|
35%
| ||
I |
Stucco: synthetic or with elastomeric finishes
|
All
|
All facades, 3rd or higher stories only
|
35%
| |
Terra Cotta or Ceramic: tiles or panels
|
All
|
All facades
|
20%
| ||
J |
Wood: painted, stained, treated, natural, or aged lap siding,
shingles, board and batten
|
All
|
All facades, no more than 100 square feet continuous area
|
20%
| |
K |
Wood, Composite: lap siding, shingles, board and batten, rain
screen system
|
All
|
All facades, no more than 100 square feet continuous area
|
35%
|
Table 535-23-5
Allowed Detail and Accent Materials
| ||
---|---|---|
All permitted major and minor facade materials may be used for
details, trim, and accents.
| ||
Material
|
Illustration
| |
M |
Concrete Details: precast stone ornamentation, lintels, sills,
banding, columns, beams
| |
—
|
Fiber Cement Details: trim, soffits
| |
N |
Metal Details: trim, ornamentation, lintels, beams, columns
| |
—
|
Wood and Wood Composite Details: painted/treated trim, soffits,
other approved details
| |
O |
Vinyl Details: limited to soffits, window trim; minimum 0.04
inch thick
|
Table 535-23-6
Prohibited Materials
| ||
---|---|---|
Material
|
Illustration
| |
Brick: thin veneer
| ||
P |
Concrete, unfinished: untreated, unstained, unpainted
| |
—
|
Fiberglass and Acrylic Panels: all
| |
Q |
Glass Block: clear or patterned units with or without color
| |
R |
Metal, Aluminum Composite: aluminum composite materials (ACM)
or panels (ACP)
| |
S |
Plastic Panels: all, including high-density polyethylene and
polycarbonate panels
| |
T |
Stucco Moldings or Synthetic Stucco Moldings: trim, sills, cornices,
banding, columns, pilasters or other 3-dimensional details
| |
Vinyl and PVC Siding: minimum 0.040 inch thick
| ||
—
|
Wood: unfinished, untreated plywood siding or panels
|
Table 535-24-1
Plant Material Size at Installation
| |
---|---|
Plant Material Type
|
Minimum Size
|
Deciduous shade/overstory tree
|
1.5 inches caliper/8 feet high
|
Evergreen tree
|
8 feet high
|
Understory tree
|
6 feet high
|
Ornamental tree
|
1.5 inches caliper
|
Shrubs, deciduous
|
5-gallon container or 18 inches balled and burlapped
|
Shrubs, evergreen
|
5-gallon container or 18 inches balled and burlapped
|
Ground cover
|
3 inches high
|
Table 535-24-2
Estimated Canopy and Permeable Surface Area by Tree Size
| ||
---|---|---|
Tree Size
|
Estimated Mature Canopy Size
(square feet)
|
Minimum Required Permeable Surface Area
(square feet)
|
Small
|
300
|
100
(e.g., 4 feet x 25 feet)
|
Medium
|
700
|
225
(e.g., 4 feet x 56.25 feet)
|
Large
|
1,000
|
400
(e.g., 4 feet x 100 feet)
|
Table 535-24-3
Side and Rear Buffer Required
| ||||||
---|---|---|---|---|---|---|
Abutting Lots Zoned:
| ||||||
Buffer Required on Lots Zoned:
|
CX
|
MX1, MX2
|
GX1, GX2, GX3
|
RX
|
R
|
P-1, P-3
|
CX
|
—
|
—
|
—
|
Landscape buffer
|
Landscape buffer
|
Landscape buffer
|
MX1, MX2
|
—
|
—
|
—
|
Fence buffer
|
Fence buffer
|
Fence buffer
|
GX1, GX2, GX3
|
—
|
—
|
—
|
Fence buffer
|
Fence buffer
|
Fence buffer
|
RX
|
—
|
—
|
—
|
—
|
Fence buffer
|
—
|
See § 535-24G(4) for activities triggering buffer requirement.
|