The purpose of this chapter is to provide objective design standards for multi-family and residential mixed-use development, as applicable according to section
17.118.020 (Applicability). The design standards contained in this section supplement the standards in chapter
17.120 (General Design Provisions) and article
VIII (Form-Based Code). If there is a conflict, the requirements of article
VIII supersede this chapter, and this chapter supersedes the requirements in chapter
17.120.
(Ord. No. 1000 § 4, 2022)
A. Frontage
road design.
1. Multi-family and residential mixed-use projects along a frontage
road must provide the following along the frontage-road facing pedestrian
area:
a. A pedestrian walkway a minimum of 12 feet in width.
b. Street furniture, which may include outdoor dining areas.
c. A minimum of two site features such as a planted trellis, a living
walls, public art, or a plaza.
2. Mid-block passageways shall be incorporated into internal paseo systems.
3. Parking within frontage roads and within private circulation drives
may be parallel, head-in angled, or back-in angled.
B. Sidewalks
abutting ground floor residential units. Where ground floor nonresidential
uses are located along private driveways within a residential mixed-use
development, the driveway must be designed with a minimum eight-foot
wide sidewalk that is visually distinct from the vehicular circulation
area.
C. Pedestrian
open spaces.
1. Pedestrian-oriented amenities. Pedestrian open spaces must include
the following:
a. Trellises or arbors with vines or other plantings; and
b. Durable street furniture and other pedestrian-oriented features,
such as period cast iron or steel street furniture, decorative wine-making
artifacts such as manual grape crushers, wine barrels for trash containers,
or similar elements.
2. Pedestrian-oriented lighting design.
a. Light fixtures and poles must be consistent in design with the primary
building.
b. Along pedestrian-oriented building perimeters, light fixtures must
be no taller than 12 feet in height.
c. Low-level lighting shall be provided to ensure entry paths, entry
stairs and driveways, and garage and building entries are illuminated.
(Ord. No. 1000 § 4, 2022)
A. Facade
articulation. Structural elements visible on the building exterior
(e.g. rafters, purlins, posts, beams, balconies, brackets, trusses,
columns, arches, etc.), even when ornamental, shall be sized and spaced
to frame building apertures and modules.
B. Porches
and balconies. Balconies and porches must be integrated into building
recesses or overhangs on at least one side of the porch or balcony.
C. Porches.
Porches must be engaged with the building facade on at least one side.
FIGURE 17.123.030-1 INTEGRATION OF BALCONIES
|
D. Townhouses/rowhouses.
In townhouse and rowhouse development types, all primary facade planes
of adjacent attached units must be offset a minimum of 18 inches to
avoid monotony in facade plane.
E. Garage
width. For rowhouses or townhouses, attached garages with doors that
face the street may not occupy more than 50 percent of the width of
any street-facing building facade.
(Ord. No. 1000 § 4, 2022)
A. Allowed
roof forms. Roof forms shall be limited to:
B. Pitch.
The pitch of a sloped roof must be a 3:12 to 6:12 ratio.
C. Parapet
design.
1. Parapets longer than 12 feet in length shall exhibit a combination
of steps and curves. Patterns of steps and curves must be symmetrical
within each segment or establish symmetry across the building facade.
If parapets terminate with a coping, the coping must be stone, concrete,
tile, or molded stucco.
2. Parapets segments may not exceed 25 feet in length without interruption
in height or form.
D. Cornices.
Where a cornice is included in roof design, the cornice must include
brackets, dentils, or other ornamentation.
E. Eaves.
Where eaves exceed 18 inches in depth, exterior brackets or beams
are required.
F. Roof
Heights. The eave or roof form of a secondary facade bay shall be
no higher than the corresponding elements of the primary facade bay.
(Ord. No. 1000 § 4, 2022)
A. Window
and door design. All upper-story windows and doors must be consistent
in design, including proportions, trim, material, and color.
B. Window
recess and trim. All windows must be either:
1. Designed with trim a minimum of one inch from the outer wall surface
and at least one inch in width; or
2. Recessed a minimum of three inches from the outer wall surface.
FIGURE 17.123.050-1 WINDOW DESIGN
|
C. Window
trim material. Foam and vinyl are not permitted window trim materials.
D. Upper
story windows. Upper story windows must be vertically oriented.
E. Ground
floor commercial windows. Ground floor windows must be horizontal
or square in proportion rather than vertically oriented.
F. Glazing.
Reflective or opaque tinting or glazing is prohibited.
(Ord. No. 1000 § 4, 2022)
A. Private
open space. All private open space must have a minimum dimension of
six feet in any direction.
B. Common
open space.
1. Common open space may be at-grade, elevated, or on the roof of a
building.
2. Common outdoor recreation space must be available for passive and
active outdoor recreational purposes for the enjoyment of all residents.
Outdoor recreation space types include, but are not limited to, open
lawn areas, picnic/barbeque areas, tot lots, sports courts, swimming
pools, and community gardens.
3. The slope of the common outdoor recreational space must not exceed
a slope of ten percent and must be easily accessible for all residents.
4. Common outdoor recreation space must not include driveways, public
or private streets, or utility easements where the ground surface
may not be appropriate for recreational space.
(Ord. No. 1000 § 4, 2022)
A. Residential
signifiers. Residential facades shall incorporate at least one element
that signals habitation, such as windows bays or balconies.
B. Unique
floor plans. All multi-family and residential mixed-use projects over
50 units must include a minimum of six unique floor plans. A mirror-image
of one floor plan does not count as a unique floor plan.
C. Private
open space. Private open space may be at-grade or elevated. Space
types include but are not limited to dooryards, decks, porches, patio,
verandas, and balconies.
D. Affordable
unit design. Affordable units and market rate units in the same development
shall be constructed of the same exterior materials and details such
that the units are not distinguishable.
E. Universal
design. For projects with at least ten dwelling units, a minimum ten
percent of units must adhere to the following principles of Universal
Design.
1. At least one entrance without steps and a flat threshold.
2. Living space on one floor or stair landings big enough to accept
lifts.
3. Wide interior doors (32-inch clear, typically provided with 36-inch
door), hallways, and alcoves with 60 by 60-inch turning space at doors,
in kitchens, and dead ends.
4. A 30 by 48-inch clear space at appliances and fixtures in bathrooms
and kitchens.
F. Required
storage. Lockable storage spaces for multiple-family units must be
provided as required by the CalGreen Building Code.
(Ord. No. 1000 § 4, 2022)
Notwithstanding the design standards of this chapter, additions
to and remodels of existing buildings, including porches, balconies,
decks, and new or replacement windows or doors in an existing wall
must match the architectural design and detail of the existing building.
(Ord. No. 1000 § 4, 2022)