All subdivisions and land developments that include the design of a mobile home park shall be subject to the following requirements and to all other applicable requirements of this chapter:
A. 
Lot requirements. All individual mobile homes located in a mobile home park shall have a minimum lot size, setback, area and side yard as required by Chapter 240, Zoning.
B. 
Size and location of mobile home parks. All mobile home parks shall meet the size and location requirements of Chapter 240, Zoning.
C. 
Foundation anchors and enclosures.
(1) 
An adequate number of foundation anchors for the placement and tie-down of the mobile home shall be provided for the purpose of stabilizing the superstructure against uplift, sliding, rotation and overturning. Foundation anchors shall be adequately designed and installed to provide adequate tie-down as required above. Anchors shall be positioned at random distances as required for tie-down purposes.
(2) 
All mobile home parks shall provide for the enclosure of the foundation area on which the mobile home unit is situated. Enclosures shall be installed within a minimum of 180 days after placement of a mobile home unit.
D. 
Off-street parking shall be provided in accordance with Chapter 240, Zoning, of the Code of the Borough of Lewistown, as amended from time to time.
E. 
Required improvements. All mobile home parks shall be served with adequate streets, sewer, water and other facilities. All mobile home parks shall comply with the required improvements set forth in Article VI of this chapter and shall conform with the design standards set forth in Article IV for residential developments. Where Chapter 240, Zoning, sets forth design regulations and required improvements for mobile home parks, those regulations shall prevail if they conflict with regulations contained within this chapter.
F. 
Other utility requirements.
(1) 
Each mobile home lot shall be provided with a suitable method for connecting the mobile home sewage drain outlet to the sewer line. Provision shall be made for plugging the sewer riser pipe when a mobile home does not occupy the lot. Surface drainage shall be diverted away from the riser. The rim of the riser pipe shall be encased in a waterproof catch basin.
(2) 
Each mobile home lot shall have a water riser pipe that connects the mobile home water system to the central water system.
(3) 
All fuel storage tanks shall be constructed in accordance with appropriate state agency and Fire Code regulations.