Section 101.1 Insert: City of Hollister.
| |
Section 105.2 Work exempt from permit. Amend: #1, #7 and Delete
#2 under Building: as follows:
| |
1. One-story detached accessory structures used as tool and
storage sheds, playhouses and similar use, provided the floor area
does not exceed one hundred twenty (120) square feet.
| |
2. Delete: Fences not over seven (7) feet (2,134 mm) high.
| |
7. Storable swimming pools as defined in Section 4201.2 that
are less than forty-two (42) inches deep.
| |
Section 106.3.1 Approval of construction documents. Delete:
"REVIEWED FOR CODE COMPLIANCE" and add "Approved For Permit."
| |
Section 301.2 Climatic and geographic design criteria, by establishing
the following data for Table 301.2(1): Insert the following information.
| |
Ground Snow Load
|
15 psf
|
Wind Speed (mph)
|
115 mph
|
Seismic Design Category
|
B
|
Weathering
|
Severe
|
Frost line depth
|
18 inches
|
Termite
|
Moderate to heavy
|
Winter Design Temp
|
9° F.
|
Ice Shield Underlayment Required
|
NO
|
Flood Hazard
|
Yes, City Code Chapter 415
|
Air Freezing Index
|
569
|
Mean Annual Temperature
|
56.6 F
|
Section 303.4 Mechanical Ventilation. Delete this Section requiring
mechanical ventilation.
| |
Section 309.5 Fire Sprinklers. Delete this Section that requires
fire sprinklers in private garages.
| |
Section 310.2.5 Replacement window. Delete this entire Section.
| |
Section 313 Automatic Fire Sprinkler Systems. Delete this entire
Section requiring automatic fire sprinkler systems in one- and two-family
dwellings and town houses.
| |
Section R314.2.2 Alterations, Repairs and Additions. Add last
sentence to read: Non-compliant emergency escape and rescue openings
located in sleeping rooms shall be replaced with those required for
new dwelling (refer to Section R310 in the International Residential
Code).
| |
Section R322.1.9 and R322.1.10 under Flood Resistant Construction.
Delete these Sections concerning manufactured homes and elevations
in flood hazard areas.
| |
Section R404.4 Retaining Walls. Change first sentence to read:
"Retaining walls that are not laterally supported at the top and that
retain in excess of twenty-four (24) inches of unbalanced fill that
are over four (4) feet tall when measured from the bottom of the footing
to top of the wall shall be designed to ensure stability against overturning,
sliding, excessive foundation pressure and water uplift."
| |
Section R609 Exterior Windows and Doors. Delete this entire
Section.
| |
Chapter 11 Energy Efficiency. Delete Sections 1102.2.6 "Steel-frame
ceilings, walls, and floors": through Section N1111.
| |
Amend Table 1102.1.1 under Climate Zone 4 to read as follows:
| |
Ceiling R-Value = 38
|
U-Factor = 0.030
|
Wood Frame Wall R-Value = 13 (2x4) or 19 (2x6)
|
U-Factor = 0.060
|
Mass Wall R-Value = 8/13
|
U-Factor = 0.098
|
Floor R-Value = 19
|
U-Factor = 0.047
|
Basement Wall R-Value = 10/13
|
U-Factor = 0.059
|
Section P2503.5 Drain, waste and vent system testing. Amend
the first sentence in P2503.5.1 Rough Plumbing to read as follows:
"DWV systems shall be tested on completion of the rough piping installation
by water or by air with no evidence of leakage."
| |
Section P2603.5.1 Freezing — Sewer Depth, Insert: eighteen
(18) inches (in two (2) locations).
| |
Section E3601.6.2 Service Disconnect Location. Amend to: Service
disconnect location. "The service disconnecting means shall be installed
at a readily accessible location outside of a building."
| |
Section E3801.2 Allowable Wiring Methods. Amend to: "The allowable
wiring methods for electrical installations shall be those listed
in Table E3801.2, Exception: Structures built on land within a designated
floodplain or land that is in low lying areas prone to flooding shall
not use non-metallic sheathed cable (NM - commonly referred to as
Romex)."
| |
Section E4002.9. 15- and 20-Ampere Receptacles in Wet Locations.
Delete: whether or not the attachment plug cap is inserted. An outlet
box hood installed for this purpose shall be listed and identified
as "extra duty." Delete: Exception.
|