In all areas of special flood hazards, compliance with the applicable
requirements of the Uniform Construction Code (N.J.A.C. 5:23) and
the following standards, whichever is more restrictive, is required:
A. Anchoring.
(1) All new construction to be placed or substantially improved and substantial
improvements shall be anchored to prevent flotation, collapse, or
lateral movement of the structure.
(2) All manufactured homes to be placed or substantially improved shall
be anchored to resist flotation, collapse or lateral movement. Methods
of anchoring may include, but are not to be limited to, use of over-the-top
or frame ties to ground anchors. This requirement is in addition to
applicable state and local anchoring requirements for resisting wind
forces.
B. Construction materials and methods.
(1) All new construction and substantial improvements shall be constructed
with materials and utility equipment resistant to flood damage.
(2) All new construction and substantial improvements shall be constructed
using methods and practices that minimize flood damage.
C. Utilities.
(1) All new and replacement water supply systems shall be designed to
minimize or eliminate infiltration of floodwaters into the system;
(2) New and replacement sanitary sewage systems shall be designed to
minimize or eliminate infiltration of floodwaters into the systems
and discharge from the systems into floodwaters;
(3) On-site waste disposal systems shall be located to avoid impairment
to them or contamination from them during flooding; and
(4) For all new construction and substantial improvements the electrical,
heating, ventilation, plumbing and air-conditioning equipment and
other service facilities shall be designed and/or located so as to
prevent water from entering or accumulating within the components
during conditions of flooding.
D. Subdivision proposals.
(1) All subdivision proposals and other proposed new development shall
be consistent with the need to minimize flood damage;
(2) All subdivision proposals and other proposed new development shall
have public utilities and facilities such as sewer, gas, electrical,
and water systems located and constructed to minimize flood damage;
(3) All subdivision proposals and other proposed new development shall
have adequate drainage provided to reduce exposure to flood damage;
and
(4) Base flood elevation data shall be provided for subdivision proposals
and other proposed new development which contain at least 50 lots
or five acres (whichever is less).
E. Enclosure openings. All new construction and substantial improvements
having fully enclosed areas below the lowest floor that are usable
solely for parking of vehicles, building access or storage in an area
other than a basement and which are subject to flooding shall be designed
to automatically equalize hydrostatic flood forces on exterior walls
by allowing for the entry and exit of floodwaters. Designs for meeting
this requirement must either be certified by a registered professional
engineer or architect or must meet or exceed the following minimum
criteria: A minimum of two openings in at least two exterior walls
of each enclosed area, having a total net area of not less than one
square inch for every square foot of enclosed area subject to flooding
shall be provided. The bottom of all openings shall be no higher than
one foot above grade. Openings may be equipped with screens, louvers,
or other covering or devices provided that they permit the automatic
entry and exit of floodwaters.
F. Manufactured homes.
(1) Manufactured homes shall be anchored in accordance with Subsection
A(2).
(2) All manufactured homes to be placed or substantially improved within
an area of special flood hazard shall:
(a)
Be consistent with the need to minimize flood damage;
(b)
Be constructed to minimize flood damage;
(c)
Have adequate drainage provided to reduce exposure to flood
damage.