Figure 550-9-1 Typical Clear Sight Triangle
(Source: The New Illustrated Book of Development Definitions,
1993)
|
Table 550-9-1
Clear Sight Triangle
| |||||
---|---|---|---|---|---|
"A" Distance
(feet)
|
"B" Distance
| ||||
Minor Access Street
(feet)
|
Local Street
(feet)
|
Collector Street
(feet)
|
Arterial Street
(feet)
| ||
15
|
Minor access street
|
15
|
30
|
100
|
150
|
30
|
Local street
|
15
|
30
|
100
|
150
|
100
|
Collector street
|
15
|
30
|
100
|
150
|
150
|
Arterial street
|
15
|
30
|
100
|
150
|
Table 550-9-2
Residential Parking Schedule
[Amended 10-6-2016 by Ord. No. 739] | |
---|---|
Residential Uses
|
Minimum Required Spaces
|
Apartment conversion
|
2 per dwelling unit, plus additional 1/2 per dwelling unit,
shall be provided in a common visitor parking compound. Such visitor
parking lot shall be sized, arranged, and located so that the spaces
are within 300 feet walking distance to any unit served.
|
Group home
|
2 per dwelling unit, plus 1 for every 4 residents
|
Mobile /manufactured home park
|
2 per dwelling unit, plus additional 1/2 per dwelling unit shall
be provided in a common visitor parking compound. Such visitor parking
lots shall be sized, arranged, and located so that the spaces are
within 300 feet walking distance to any unit served.
|
Multifamily dwelling
|
2 per dwelling unit, plus additional 1/2 per dwelling unit,
shall be provided in a common visitor parking compound. Such visitor
parking lots shall be sized, arranged, and located so that the spaces
are within 300 feet walking distance to any unit served.
|
Single-family attached dwelling
|
2 per dwelling unit, plus additional 1/2 per dwelling unit,
shall be provided in a common visitor parking compound. Such visitor
parking lots shall be sized, arranged, and located so that the spaces
are within 300 feet walking distance to any unit served.
|
Single-family detached dwelling
|
2 per dwelling unit
|
Single-family semidetached dwelling
|
2 per dwelling unit
|
Two-family detached dwelling
|
2 per dwelling unit
|
Other residential uses
|
Other residential uses not specified in this parking schedule:
Number of spaces normally required for similar uses listed elsewhere
within this parking schedule table
|
Table 550-9-3
Nonresidential-Commercial Parking Schedule
| |
---|---|
Commercial Uses
|
Minimum Required Spaces
|
Animal hospital
|
2 per exam table, plus 1 per employee on the peak shift
|
Art gallery
|
1 per 300 square feet of gross floor area open to and accessible
to the public, plus 1 per employee on the peak shift
|
Automobile, boat, heavy equipment, mobile home, recreational
vehicle and similar motor vehicle rental/sales, repair/service, washing
and/or fuel/gas sales, individual or in combination of the associated
uses in next column:
|
1 per employee on the peak shift plus:
|
Rental/sales: 1 per 15 vehicles or units of motor vehicle equipment
| |
Repair/service: 2 per service bay
| |
Washing: 1 per 200 square feet of office floor area
| |
Fuel/gasoline sales/distribution: 1 per fuel pump which may
be provided at fuel pumps at a ratio of not more than 2 per every
pump (1 on each side), plus 1 for every employee on the peak shift
| |
Bank
|
1 per 400 square feet of gross floor area, plus 1 per employee
on the peak shift
|
Bed-and-breakfast
|
2 per dwelling unit of owner/resident manager and other permanent
residents of the dwelling, plus 1 for every guest/sleeping room
|
Other uses beyond the dwelling unit and guest/sleeping rooms,
and open to the public: Number of spaces normally required for uses
listed elsewhere within these parking schedule tables
| |
Beer and ale wholesale distribution
|
1 per 400 square feet of gross floor area open to and accessible
to the public, plus 1 per employee on the peak shift
|
Boarding house
|
2 per dwelling unit of owner/resident manager and other permanent
residents, plus 1 space for every sleeping/rooming unit for let
|
Commercial recreation, indoor
|
1 per 200 square feet of gross floor area, plus 1 per employee
on the peak shift
|
Commercial recreation, outdoor
|
1 per 200 square feet of gross floor area for enclosed structures,
plus 1 per employee on the peak shift; or if completely outside of
a structure, 1 per every 3 users at maximum utilization, plus 1 per
employee on the peak shift
|
Convenience store
|
1 per 100 square feet of net retail floor area, plus 1 per fuel
pump, plus 1 per employee on the peak shift
|
Copy shop/business service
|
1 per 200 square feet of net floor area, plus 1 per employee
on the peak shift
|
Craftsman/artisan studio
|
1 per 300 square feet of gross floor area, plus 1 per employee
on the peak shift
|
Farmer's market and/or flea market, outdoor
|
1 per 400 square feet of gross floor area open to and accessible
to the public, plus 1 per employee on the peak shift
|
Financial service, other
|
1 per 400 square feet of gross floor area, plus 1 per employee
on the peak shift
|
Food service
|
1 per employee on the peak shift plus:
|
Delivery: 1 per vehicle stored on site
| |
Direct patron food sales/consumption: 1 per 6 seats if restaurant
is provided or 1 per 200 square feet of gross floor area open to and
accessible to the public, whichever is greater
| |
Funeral home
|
25 for first parlor, plus 10 for every additional parlor
|
Heliport
|
2 per helicopter based at facility
|
Home improvement center, lumber sales facility, and building
materials sales
|
1 per 500 square feet of gross floor area (indoor and outdoor)
open to and accessible to the public, plus 1 per employee on the peak
shift
|
Hotel
|
1 per guest/sleeping room, plus 1 per employee on the peak shift,
plus 1/2 of the spaces normally required for accessory uses listed
elsewhere within these parking schedule tables
|
Kennel, commercial
|
1 per every 15 animals based on maximum animal capacity, plus
1 per employee on the peak shift
|
Laundry and dry cleaning establishment, personal
|
1 per 300 square feet of net floor area, plus 1 per employee
on the peak shift
|
Liquor store
|
1 per 200 square feet of net floor area, plus 1 per employee
on the peak shift
|
Mini storage warehouse
|
1 per 25 storage units, plus 1 per employee on the peak shift
|
Motel
|
1 per guest/sleeping room, plus 1 per employee on the peak shift,
plus 1/2 of the spaces normally required for accessory uses listed
elsewhere within these parking schedule tables
|
Nightclub
|
1 per 100 square feet of net floor area, plus 1 per employee
on the peak shift
|
Office, business and professional
|
1 per 300 square feet of gross floor area, plus 1 per employee
on the peak shift
|
Office, medical
|
2 per patient examination room, plus 1 per employee on the peak
shift
|
Parking lot/parking structure
|
No minimum required
|
Personal service
|
1 per 300 square feet of net floor area, plus 1 per employee
on the peak shift
|
Restaurant, fast-food
|
1 per 2 seats, plus 1 for every 2 employees on the peak shift
|
Restaurant, sit-down
|
1 per 4 seats, plus 1 for every 2 employees on the peak shift
|
Retail business
|
1 per 200 square feet of net retail floor area, plus 1 per employee
on the peak shift
|
School, commercial
|
1 per 4 students, plus 1 per employee on the peak shift
|
School, vocational
|
1 per 4 students, plus 1 per employee on the peak shift
|
Sexually oriented business and/or related use
|
1 per 200 square feet of net floor area, plus 1 per employee
on the peak shift
|
Shopping center, general
|
Number of spaces normally required for similar uses listed elsewhere
within these parking schedule tables
|
Shopping center, town
|
Number of spaces normally required for similar uses listed elsewhere
within these parking schedule tables
|
Tattoo parlor/body piercing
|
1 per 300 square feet of net floor area, plus 1 per employee
on the peak shift
|
Tavern/bar
|
1 per 4 seats, plus 1 for every 2 employees on the peak shift
|
Theater, indoor
|
1 per 4 seats based on maximum seating capacity, or 1 per 400
square feet of gross floor area, whichever is larger
|
Therapeutic massage facility
|
1 per table, plus 1 per employee on the peak shift
|
Veterinary office
|
2 per exam table, plus 1 per employee on the peak shift
|
Other commercial uses
|
Other commercial uses not specified in this parking schedule:
Number of spaces normally required for similar uses listed elsewhere
within this parking schedule table
|
Table 550-9-4
Nonresidential-Industrial Parking Schedule
| |
---|---|
Industrial Uses
|
Minimum Required Spaces
|
Automobile wrecking, junk and scrap storage and sales
|
1 per 1/2 acre, plus 1 per employee on the peak shift
|
Industrial use, general
|
1 per 1,000 square feet of gross floor area of the building
up to 20,000 square feet, plus 1 for every 2,000 square feet gross
floor area of the building up between 20,000 square feet and 40,000
square feet, plus 1 for every 3,000 square feet gross floor area of
the building in excess of 40,000 square feet. In addition to the off-street
parking requirements and when there are 10 or more loading berths
provided, trailer parking spaces shall be provided at 1 trailer parking
space for every 4 loading berths.
|
Industrial use, light
|
1 per 1,000 square feet of gross floor area of the building
up to 20,000 square feet, plus 1 for every 2,000 square feet gross
floor area of the building up between 20,000 square feet and 40,000
square feet, plus 1 for every 3,000 square feet gross floor area of
the building in excess of 40,000 square feet. In addition to the off-street
parking requirements and when there are 10 or more loading berths
provided, trailer parking spaces shall be provided at 1 trailer parking
space for every 4 loading berths.
|
Laundry and dry cleaning, industrial
|
1 per 1,000 square feet of gross floor area of the building
up to 20,000 square feet, plus 1 for every 2,000 square feet gross
floor area of the building up between 20,000 square feet and 40,000
square feet, plus 1 for every 3,000 square feet gross floor area of
the building in excess of 40,000 square feet. In addition to the off-street
parking requirements and when there are 10 or more loading berths
provided, trailer parking spaces shall be provided at 1 trailer parking
space for every 4 loading berths.
|
Mineral extraction
|
1 per employee on the peak shift, plus 1 per stored vehicle
|
Outdoor storage
|
1 per employee on the peak shift
|
Research and development
|
1 per 400 square feet of gross floor area
|
Solid waste transfer facility
|
1 per employee on the peak shift
|
Warehousing, distribution, and wholesaling
|
1 per 1,000 square feet of gross floor area of the building
up to 20,000 square feet, plus 1 for every 2,000 square feet gross
floor area of the building up between 20,000 square feet and 40,000
square feet, plus 1 for every 3,000 square feet gross floor area of
the building in excess of 40,000 square feet. In addition to the off-street
parking requirements and when there are 10 or more loading berths
provided, trailer parking spaces shall be provided at 1 trailer parking
space for every 4 loading berths.
|
Other industrial uses
|
Other industrial uses not specified in this parking schedule:
Number of spaces normally required for similar uses listed elsewhere
within this parking schedule table
|
Table 550-9-5
Nonresidential-Institutional/Civic Parking Schedule
| |
---|---|
Institutional/Civic Uses
|
Minimum Required Spaces
|
Cemetery
|
5, plus 1 per employee on the peak shift
|
Clinic, medical
|
4 per patient examination room, plus 1 per employee on the peak
shift
|
Clubhouse or lodge, private
|
1 per 200 square feet of gross floor area, plus 1 per employee
on the peak shift
|
Community center
|
1 per 400 square feet of gross floor area open to and accessible
to the public, plus 1 per employee on the peak shift
|
Continuing care retirement facility
|
Personal care or nursing care centers: 1 for every 4 beds plus
1 per employee on largest shift
|
Apartment units: 1 per dwelling unit
| |
Cottage units (single-family units): 1 per dwelling unit, plus
1 per 5 units for guest parking
| |
Other uses not specified in this parking schedule: Number of
spaces normally required for uses listed elsewhere within these parking
schedule tables
| |
Convention center
|
1 per 4 seats based on maximum seating capacity, or 1 per 400
square feet of gross floor area, whichever is larger
|
Day care, commercial
|
1 per employee on the peak shift plus 1 per 6 nonresident (adult
or child) enrolled or being cared for
|
Emergency services
|
1 per 400 square feet of gross floor area, plus 1 per stored
vehicle
|
Government facility, other than municipal-owned use
|
Number of spaces normally required for uses listed elsewhere
within these parking schedule tables
|
Group care facility
|
2 per dwelling unit, plus 1 for every 4 residents
|
Hospital
|
2 per 3 beds, plus 1 per employee on the peak shift
|
Library
|
1 per 400 square feet of gross floor area open to and accessible
to the public, plus 1 per employee on the peak shift
|
Long-term care facility or personal care facility
|
Personal care or nursing care centers: 1 for every 4 beds plus
1 per employee on largest shift
|
Other uses not specified in this parking schedule: Number of
spaces normally required for uses listed elsewhere within these parking
schedule tables
| |
Museum
|
1 per 400 square feet of gross floor area open to and accessible
to the public, plus 1 per employee on the peak shift
|
Municipal-owned use
|
Number of spaces normally required for uses listed elsewhere
within these parking schedule tables
|
Park, playground, and other noncommercial outdoor recreational
use
|
3 per acre
|
Place of worship
|
1 per 4 seats based on maximum seating capacity, or 1 per 400
square feet of gross floor area, whichever is larger
|
Post office
|
1 per 200 square feet of net floor area, plus 1 per employee
on the peak shift
|
Public/private works facility
|
1 per employee on the peak shift, plus 1 per vehicle stored
on site
|
Recycling collection point
|
1 per container for each type of material stored
|
School, public or private
|
Primary, grades K-6: 1 per every 30 students enrolled, plus
1 per employee, plus 1 per every 30 seats for auditorium, gymnasium,
or multipurpose room
|
Secondary and above, grades 7+: 1 per every 5 students enrolled,
plus 1 per employee, plus 1 per every 30 seats for auditorium, gymnasium,
or multipurpose room
| |
Treatment center
|
1 for every 3 patients/clients, plus 1 per employee on the peak
shift
|
University/college
|
1 per 5 students enrolled, plus 1 space per employee, plus 1
per every 30 seats for auditorium, gymnasium, or multipurpose room
plus, 1 space per 4 occupants in a dormitory
|
Other institutional/civic uses
|
Other institutional/civic uses not specified in this parking
schedule: Number of spaces normally required for similar uses listed
elsewhere within this parking schedule table
|
Table 550-9-6
Nonresidential-Forestry/Agriculture Parking Schedule
| |
---|---|
Forestry/Agriculture Uses
|
Minimum Required Spaces
|
Agricultural operation
|
2 per dwelling unit, plus 1 for every nonresident employee on
the peak shift
|
Community garden
|
3 per acre
|
Forestry (timber harvesting)
|
1 per employee on the peak shift
|
Plant nursery
|
1 per 500 square feet of gross floor area (indoor and outdoor)
open to and accessible to the public, plus 1 per employee on the peak
shift
|
Other forestry/agriculture uses
|
Other forestry/agriculture uses not specified in this parking
schedule: Number of spaces normally required for similar uses listed
elsewhere within this parking schedule table
|
Table 550-9-7
Nonresidential-Miscellaneous Parking Schedule
| |
---|---|
Miscellaneous Uses
|
Minimum Required Spaces
|
Communications antenna, communications tower, and communications
equipment building
|
Fully automated site: 1 per site
|
Not fully automated site: 1 per employee on peak shift
| |
Billboard
|
1 per billboard structure
|
Other miscellaneous uses
|
Other miscellaneous uses not specified in this parking schedule:
Number of spaces normally required for similar uses listed elsewhere
within this parking schedule table
|
Table 550-9-8
Accessory Parking Schedule
| |
---|---|
Accessory Use
|
Minimum Required Spaces
|
Automated banking
|
2 when not associated with on-site principal bank or other financial
service; otherwise, no minimum required
|
Community garden
|
No minimum required
|
Day care, accessory
|
2 per dwelling unit as part of principal use
|
Day care, family
|
2 per dwelling unit as part of principal use, plus 1 per nonresident
employee, plus 1 for patron use
|
Drive-through facility for permitted use
|
No minimum required
|
Home occupation
|
2 per dwelling unit as part of principal use, plus 1 per nonresident
employee
|
No-impact home occupation
|
2 per dwelling unit as part of principal use
|
Outdoor cafe/dining
|
No minimum required
|
Outside displays and sales
|
No minimum required
|
Table 550-9-9
Parking Standards
| ||||
---|---|---|---|---|
Angle
|
Minimum Required Parking Space Width Measured from Inside
Edge of Any Parking Space Striping
(feet)
|
Minimum Required Parking Space Depth
(feet)
|
Minimum Required Access Aisle Width: One-Way Traffic
(feet)
|
Minimum Required Access Aisle Width: Two-Way Traffic
(feet)
|
Parallel
|
8
|
22
|
12
|
20
|
0.1° to 34.99°
|
10
|
19
|
12
|
20
|
35° to 54.99°
|
10
|
21
|
15
|
20
|
55° to 89.99°
|
10
|
22
|
18
|
24
|
90°
|
9
|
18
|
20
|
24
|
Table 550-9-10
Shared Parking Calculations
| ||||||
---|---|---|---|---|---|---|
Uses
|
Monday through Friday Times
|
Saturday and Sunday Times
| ||||
8:00 a.m. to 6:00 p.m.
|
6:00 p.m. to Midnight
|
Midnight to 8:00 a.m.
|
8:00 a.m. to 6:00 p.m.
|
6:00 p.m. to Midnight
|
Midnight to 8:00 a.m.
| |
Residential
|
60%
|
100%
|
100%
|
80%
|
100%
|
100%
|
Office
|
100%
|
10%
|
5%
|
5%
|
5%
|
5%
|
Retail
|
90%
|
80%
|
5%
|
100%
|
60%
|
5%
|
Hotel
|
70%
|
100%
|
100%
|
70%
|
100%
|
100%
|
Restaurant
|
70%
|
100%
|
10%
|
70%
|
100%
|
20%
|
Theater
|
40%
|
80%
|
10%
|
80%
|
100%
|
10%
|
Entertainment (including clubhouses and lodges)
|
40%
|
100%
|
10%
|
80%
|
100%
|
50%
|
Public/institutional/school (non-place of worship)
|
100%
|
40%
|
5%
|
10%
|
10%
|
5%
|
Places of worship
|
20%
|
40%
|
5%
|
100%
|
50%
|
5%
|
Table 550-9-11
Off-Street Loading Requirements
| ||
---|---|---|
Type of Use
|
Gross Floor Area
(square feet)
|
Number of Loading Spaces
|
Commercial (retail/service)
Wholesale
Industrial/ manufacturing
Hospitals
Laundry
Institutional and similar uses
|
< 10,000
|
0
|
10,000 to 50,000
|
1
| |
> 50,000 to 100,000
|
2
| |
> 100,000 to 250,000
|
3
| |
Each additional 250,000
|
1
| |
Office buildings and hotels
|
< 10,000
|
0
|
10,000 to 100,000
|
1
| |
> 100,000 to 300,000
|
2
| |
> 300,000
|
3
|
Table 550-9-12
Stacking Lane Requirements
| |
---|---|
Use
|
Required Stacking Space
|
Bank and other financial institution with drive-through/drive-up
window and/or ATM
|
4 vehicles/lane or kiosk
|
Restaurant, fast food or food service, fast food
|
4 vehicle lengths behind menu board; and 4 vehicle lengths behind
first window
|
Photo processing/pharmacy
|
2 vehicles/window or kiosk
|
Laundry and dry cleaning
|
2 vehicles/window or kiosk
|
Motor vehicle service stations/fueling pumps
|
2 vehicles/pump
|
Gated parking lot entrance
|
1 vehicle/gate
|
Gated unit or overhead door
|
1 vehicle/door
|
Hospital
|
4 emergency vehicles
|
Motor vehicle washing facility
|
2 vehicle lengths per bay; and 2 vehicle lengths for drying
|