Yard Minimum
|
Maximum Building Height
| |||||||||
---|---|---|---|---|---|---|---|---|---|---|
District
|
Minimum Area
(acres)
|
Lot Frontage
(feet)
|
Front
|
Side
|
Rear
|
Stories
|
Feet
|
Maximum Coverage by Building
| ||
Residence R-1
|
1
|
150
|
40
|
25
|
40
|
2.5
|
35
|
10%
| ||
Residence R-3
|
3
|
225
|
40
|
25
|
40
|
2.5
|
35
|
10%
| ||
Residence R-D
|
1/2
|
100
|
30
|
15
|
20
|
2.5
|
35
|
25%
| ||
Commercial C
|
1/2
|
100
|
30
|
15
|
40
|
2.5
|
35
|
30%
| ||
Manufacturing M
|
3
|
225
|
100
|
15
|
50
|
2.5
|
35
|
20%
| ||
VCOD
|
0.10
|
50
|
5 (1,2,3)
|
3 (3,4)
|
15 (3)
|
2.5
|
35
|
75%
| ||
MOD
|
1/2
|
100
|
30
|
15
|
40
|
2.5
|
35
|
30%
|
FOOTNOTES
| |
1.
|
The five-foot setback is only applicable "as of right" to buildings
or uses with less than 4,500 square feet gross floor area.
|
2.
|
The front setback may be reduced by special permit, as provided
for by Section 4.10, to less than five feet where a sidewalk exists
along the street and at least one entrance to the building is located
along the sidewalk.
|
3.
|
For buildings or uses greater than 4,500 square feet in gross
floor area, the setback requirements of the underlying Commercial
District shall apply, except that the underlying Commercial District
setback requirements may be reduced by special permit as provided
for by Section 4.10.
|
4.
|
Total setback of both sides shall be equal to six feet. The
total may be all on one side, all on the other side, or divided in
any proportion.
|
5.
|
Ground-mounted solar photovoltaic installations shall meet yard
setback requirements, except that setback requirements may be reduced
by special permit as a part of the special permit granted for the
underlying use.
|
6.
|
Solar energy systems shall not be included in calculations for
lot coverage or impervious surface.
|
7.
|
Ground-mounted solar energy generation systems at any scale
shall not exceed 15 feet above the ground as measured under each panel
module, except the overall height of tracking-type systems may exceed
20 feet for transient conditions when dumping snow.
|
8.
|
The size of a small-scale solar photovoltaic system, defined
as having a total collector area of 750 square feet or less, may be
increased by the SPGA per Subsection 9.2.6.
|
Exceptions to Rules in Table of Dimensional Requirements:
| |
1.
|
Side yards and/or rear yards of commercial or manufacturing
uses shall be at least 50 feet when adjacent to a Residence District.
|
2.
|
When a side or rear yard borders on a street, the minimum distance
between the street and any type of building shall be as follows: R-3,
40 feet; R-D, 30 feet; C, 10 feet; M, 100 feet; and R-1, 35 feet.
|