All PVS gravity sewer pipe shall conform to the requirements
of the latest version of ASTM specification, 3033 or 3034 PVC sewer
pipe and fittings.
A. Minimum size: four inches.
B. Elastometric gasket joints Schedule 35.
C. Absolutely no glue joints.
D. Fernco couplings are allowable where needed.
(1) Strong back RC repair couplings.
(2) 5000 series RC couplings.
E. Minimum pitch of 1/2 inch per foot shall be maintained.
F. A test tee must be installed at the start of the property line.
G. One dual direction cleanout is to be installed on the sewer lateral
directly outside of the building. Additional cleanouts are required
after every change of direction over a forty-five-degree angle and
every 75 feet of lateral installed.
H. (All work and material must be inspected prior to be covered.) Inspection
done by the Township-approved inspectors and must be done Monday through
Friday. A minimum of at least 48 hours must be given.
I. This includes water from all sources/other suppliers/private wells,
now in effect or may be in effect in the future for the purpose of
establishing metered sewer rates based on water consumption for metered
water customers and for nonmetered water customers charging at a flat
rate (rates, rules and regulations).
The Township shall not be liable for any damage resulting from
leaks, broken pipes or from any other cause, occurring to or within
any house or building, or between the curb and any house or building.
It is expressly stipulated by and between the Township and the property
owners that no claim shall be made against the Township on account
of bursting lines or breaking of any water mains, sewer line or connection
of any attachment to the water and sewer system.