This article sets forth the submission requirements for the
various categories of subdivision, site plan and variance applications
to the Planning Board and the Zoning Board of Adjustment. The following
general procedures shall apply to the completeness review of applications:
A. In order to be determined complete for review by the Board, all of
the required information must be submitted; provided, that the applicant
may request that one or more of the submission requirements be waived.
A written request, explaining the basis for such request(s) must be
submitted for such waiver requests in order to be considered. The
Board or its authorized committee shall grant or deny the waiver request
within 45 days of receipt of the written request.
B. If more than one development application category is to be considered
by the Board, the applicant shall be required to submit the information
required for all of the individual applications. The applicant shall
have the option of submitting separate drawings and documents for
each type of application, or drawings and documents which combine
the required information for the various types of applications.
C. Nothing herein shall be construed as diminishing the applicant's
obligation to prove in the application process that he is entitled
to approval of the application.
D. The Board may subsequently require correction of any information
found to be in error and submission of additional information not
specified in this ordinance or any revisions in the accompanying documents,
as well as the submission of any information previously waived, as
are reasonably necessary to make an informed decision as to whether
the requirements necessary for approval of the application have been
met. The application shall not be deemed incomplete for lack of any
such additional information or any revisions in the accompanying documents
so required by the Board.
In addition to the submission requirements for the individual
categories of applications in the following sections, all categories
of applications, except for conceptual site plans and conceptual subdivisions,
shall be required to submit the following:
A. For purposes of completeness review only, three paper copies of the
appropriate application form(s). Thereafter, if the review determinations
that the application is complete, the applicant shall submit three
completed and signed paper originals and 18 paper copies (if submitting
to the Planning Board) or one completed and signed paper original
and 10 paper copies (if submitting to the Zoning Board of Adjustment)
of the appropriate application form(s). A digital copy in PDF format
of the appropriate application form(s) shall also be submitted. Notwithstanding
the above, the Board Secretary may require a greater or lesser number
of copies in particular cases as appropriate. If any item on the form
is not applicable, is unknown or is otherwise unable to be completed,
the item shall not be left blank, but the words "not applicable,”
"unknown," "none" or other appropriate language shall be used.
[Amended 11-12-2019 by G.O. No. 2150; 9-14-2021 by G.O. No. 2222]
B. Written description of the application, including a description of
the proposed use and improvements.
C. Statement indicating all of the provisions of the Land Use Ordinance
from which a waiver or variance is sought, together with a statement
of reasons why same should be granted. The statement shall include
both existing and proposed violations of the Land Use Ordinance.
D. Receipt indicating that applicable fees and initial escrow deposits
are paid.
E. Certificate from the Tax Collector indicating that all taxes and
assessments for the subject property are paid up to and including
the most recent collection period.
F. Certificate from both the Board of Adjustment and the Planning Board
indicating the nature and date of prior actions, if any, by the respective
boards affecting the subject property, and a copy of the board resolutions
of such actions.
G. Affidavit of ownership. If applicant is not the owner, applicant's
interest in land must be indicated; e.g., tenant, contract/purchaser,
lien holder, etc., and permission of property owner to file the application
must be submitted.
H. If applicant is a corporation or partnership applying to the Board
or the Council for permission to subdivide a parcel of land into six
or more lots, or applying for a variance to construct a multiple dwelling
of 25 or more family units or for approval of a site to be used for
commercial purposes, list the names and addresses of all stockholders
or individual partners owning at least 10% of its stock of any class
as required by § 8.26.
I. A statement of any and all approvals which are required from other
governmental entities.
J. For minor subdivisions, preliminary major site plans and preliminary
major subdivisions, one of the following when in the opinion of the
Town Engineer there exists or there is substantial likelihood that
there exists on the subject property or on adjacent property freshwater
wetlands which could materially affect the proposed development pursuant
to rules promulgated under the Freshwater Wetlands Protection Act:
1. A letter of interpretation from the N.J.D.E.P. indicating the absence
of freshwater wetlands, or indicating the presence and verifying the
boundaries of freshwater wetlands, and classifying same by resource
value;
2. A letter of exemption from the N.J.D.E.P. certifying that the proposed
activity is exempt from the Freshwater Wetlands Protection Act, and
regulations promulgated thereunder;
3. A copy of any application made to the N.J.D.E.P. for any permit concerning
a proposed regulated activity in or around freshwater wetlands; or
4. Documentation demonstrating that no wetlands exist on the subject
property, and demonstrating that no wetlands exist on adjacent property
that would affect or limit development on the property which is the
subject of the development application.
K. A copy of any protective covenants or deed restrictions, if any,
affecting the property in question; or an affidavit from the owner
certifying that no such covenants or restrictions exist.
L. Photographs depicting the subject site, the existing structure from
all sides, site improvements, roadway access and yard areas.
[Amended 3-27-2012 by Ord. No. 1983]
[Amended 11-12-2019 by G.O. No. 2150; 9-14-2021 by G.O. No. 2222]
In addition to the submission requirements for the individual
categories of applications in the following sections, all categories
of applications, except for conceptual site plans and conceptual subdivisions,
shall be required to submit three paper copies of the required plot
plan, site plan, or subdivision plan, for purposes of completeness
review only. Thereafter, if the review determinations that the application
is complete, the applicant shall submit 18 paper copies, if submitting
to the Planning Board, or 11 paper copies, if submitting to the Zoning
Board of Adjustment, of any required plot plan, site plan or subdivision
plan, signed and sealed by the professional who prepared the plot
plan, site plan or subdivision plan, and a digital copy in PDF format.
If review by the Architectural Review Board is required, five additional
paper copies of the plan shall be submitted. Notwithstanding the above,
the Board Secretary may require a greater or lesser number of paper
copies in particular cases as appropriate. Any plan submitted as part
of an application to a Town agency shall be prepared by an individual
pursuant to the regulations in N.J.A.C. 13:27, 13:40, and 13:41, as
amended, provided that the owner of a single-family detached or two-family
dwelling may sign the plans for an application if he has prepared
them. All such plans shall contain the following information:
A. Title block containing the type of application, name and address
of applicant and owner; name, address, signature, license number and
seal of plan preparer; existing lot and block numbers; municipality
and county, date prepared and date(s) of all plan amendments.
B. Signature block for signatures of Chairman and Secretary of the Board.
C. The name of all adjoining property owners as disclosed by current
Town tax records.
D. A key map showing the location of the tract to be considered in relation
to the surrounding area within at least 500 feet of the subject property.
E. Scale of map, both written and graphic. The scale shall consist of
no more than 50 feet to the inch.
G. Zoning district in which parcel is located, and the zone district
of adjacent property, along with the standardized zoning table provided
by the Zoning Officer, placed upon the plan, indicating tract area,
lot area(s), lot width(s), all yard setbacks, building and impervious
coverage, building height, floor area ratio, density and number of
parking spaces, both as to required, existing and proposed, for the
subject property. If the application involves a conditional use, compliance
with the applicable conditional use standards shall be indicated on
the plan.
H. Existing and proposed boundaries of the site(s) in question, with
bearings and dimensions of same. The number of each existing tax lot
in accordance with the tax map shall be shown.
I. Municipal boundary line(s), if any, crossing or adjacent to the subject
property.
J. Location and width of existing easements or rights-of-way on or abutting
the subject property, including but not limited to streets, utility
and drainage easements, sight easements and access easements.
K. Location of existing and proposed buildings, with setbacks from property
lines dimensioned on the plan.
L. Location of existing and proposed paved areas, including parking
and loading areas, driveways, sidewalks, etc., showing the design
of such areas.
M. Location of natural features, including woodlands, all trees as required by the Tree Preservation Ordinance, Chapter
29A of the Code of the Town of Westfield; streams and other water bodies; wetlands if required pursuant to § 9.02J; flood hazard areas and rock outcrops on the property; and any of the foregoing on adjacent properties if same affect the proposed development.
N. Location of any required dedication or reservation for streets or
any area shown on the Official Map or Master Plan.
O. Soil erosion and sedimentation control plan, if required pursuant
to the Soil Erosion and Sediment Control Act.
P. Construction details and specifications sufficient to illustrate
the nature of site improvements, including but not limited to the
following, when appropriate: paving, curbing, walls, fences, utility
and storm drainage structures, soil erosion control structures, tree
protection devices, light fixtures and standards, signs, planting
and staking details, and barrier-free access design.
Applications for informal review of conceptual site plans and/or
subdivisions shall be required to submit a plan of the proposed development.
The procedures for completeness review of formal applications shall
not apply to such plan, except as provided below; however, the Board
Secretary shall refer the plan to the appropriate persons and agencies,
who shall provide suggestions as to any additional information that
may be helpful to the Board in reviewing the plan. The applicant may
choose to proceed without providing such additional information, or
may provide some or all of the suggested information. Once the applicant
has finalized his plan submittal, the application shall be scheduled
for the Board's agenda; provided that any application for informal
review shall provide the following prior to referral or review by
the Board:
A. Three completed and signed paper originals, 18 paper copies of the
appropriate application form, and a digital copy in PDF format.
[Amended 11-12-2019 by G.O. No. 2150]
B. Eighteen paper copies of the concept plan and a digital copy in PDF
format.
[Amended 11-12-2019 by G.O. No. 2150]
C. Written description of the application, including a description of
the proposed use and improvements.
D. Receipt indicating that applicable fees and initial escrow deposits
are paid.
E. Certificate from the Tax Collector indicating that all taxes and
assessments for the subject property are paid up to and including
the most recent collection period.
In addition to the requirements indicated in § 9.02
and § 9.03, the information below shall be shown on the
plans for all minor subdivision applications. Minor subdivision plans
to be filed with the County Recording Officer shall use a sheet size
of either 8.5 inches by 13 inches, 15 inches by 21 inches, 24 inches
by 36 inches or 30 inches by 42 inches.
B. Dimensions, bearings, and curve data for all property lines and easements.
C. Location and description of existing and proposed monuments, including
monuments where found, monuments set or reset, and monuments to be
set or reset.
D. Proposed lot and block numbers for each proposed lot.
E. Reference meridian for north arrow shown graphically.
G. Required building envelopes drawn for each lot, showing graphically
and by dimension the minimum front, side and rear yard setbacks, as
well as any easements within which the construction of buildings is
prohibited.
H. Location, dimensions and nature of existing and proposed improvements
in any streets, within or abutting the tract.
I. Existing and proposed topographic contours, both for the tract and
for adjacent areas affecting the development. Contour intervals shall
not exceed the following: up to 10% grade, two feet; over 10% grade,
five feet. Contour elevations shall be referenced to the New Jersey
Geodetic Control Survey datum.
J. The location of existing buildings on existing lots adjacent to the
subject property for a distance of 100 feet from the perimeter lot
lines of the subject property.
[Amended 3-27-2012 by Ord. No. 1984]
K. Location of existing and proposed wells and septic systems and location
of existing and proposed connections to public water and sanitary
sewer systems, as well as connections to other utilities.
L. Certification from a licensed surveyor as to the accuracy of the
details on the plat and as to compliance with provisions of the Map
Filing Law.
M. Certification from a licensed surveyor as to the setting of monuments
or from the Town Clerk as to the posting of a bond for the future
setting of monuments.
N. Certification from the Town Engineer as to the plat's compliance
with the provisions of the Map Filing Law and all applicable Town
ordinances and requirements.
O. A statement from the Town Engineer that he has received a map showing
all utilities in exact location and elevation identifying those portions
already installed and those to be installed, and that the developer
has installed all improvements in accordance with all Town regulations,
and/or a statement by the Town Clerk that proper performance guarantees
have been posted with the Town Council for the installation of required
improvements.
P. When approval of a plat is required by an officer or agency of the
Town, County or State, such approval shall be referenced and certified
on the plat.
In addition to the requirements indicated in § 9.02
and § 9.03, the information below shall be shown on the
plans for all preliminary major subdivision applications:
A. The proposed name of the subdivision.
B. Curve data for all property lines.
C. Proposed lot and block numbers for each proposed lot.
D. Required building envelopes drawn for each lot, showing graphically
and by dimension the minimum front, side and rear yard setbacks, as
well as any easements within which the construction of buildings is
prohibited.
E. Location and use of open space, if any, to be deeded to the Town
or controlled by an open space organization, as well as the use and
nature of any other common areas.
F. Location, dimensions and nature of existing and proposed improvements
in any streets, within or abutting the tract for a minimum distance
of 200 feet beyond the tract boundaries, including profiles and cross-sections
for all proposed streets, sidewalks, alleys, and planting strips;
radii, points of curvature and tangency and central angles of all
curves, both centerline and curb.
G. Existing and proposed water supply, including plans and profiles
of proposed water mains, pipe material and sizes, valves, joints,
hydrants and location of private wells.
H. Existing and proposed sanitary sewer service, and existing septic
disposal tanks, lines and fields. If connection to public sanitary
sewers is contemplated, the applicant shall submit plans and profiles
of proposed sanitary sewer lines; pipe length, material and sizes;
location of pumping stations, manholes and other structures; and appropriate
elevations.
I. Plans and profiles of existing and proposed storm drainage design
and improvements, including a map showing the entire drainage area;
the drainage area contributing to each pertinent drainage structure;
drainage tabulation sheets showing calculations for each drainage
area; length, size and material of drain pipes; direction of flow;
location of inverts, manholes, dry wells, groundwater recharge basins,
swales, drainage basins and other structures; and elevations of grates,
inverts, etc.
J. Proposed location of easements for gas, electric, telephone and cable
television service.
K. Existing and proposed topographic contours, both for the tract and
for adjacent areas affecting the development. Contour intervals shall
not exceed the following: up to 10% grade, one foot; over 10% grade,
five feet. Contour elevations shall be referenced to the New Jersey
Geodetic Control Survey datum.
L. If regrading near existing buildings is proposed, proposed spot grades
at the corners of all buildings, and finished floor elevations of
buildings.
M. Location and description of existing and proposed street trees, landscaping
and natural vegetation to remain. Information for proposed plantings
shall include common and scientific names, number of plants, planted
size and root specification.
N. The location and design of fences, walls, sidewalks and similar improvements
to be proposed.
O. If development is proposed in phases or stages, a phasing plan.
P. Proposed street lighting plan.
[Amended 9-29-2009 by Ord. No. 1945]
Q. A developer
of affordable housing shall incorporate on the plan a table identifying
the location, required bedroom distribution, and intended occupancy
(low- or moderate-income) of all affordable units, in compliance with
the Uniform Housing Affordability Controls set forth in N.J.A.C. 5:80-26.1.
[Added 4-28-2020 by G.O. No. 2165]
In addition to the requirements indicated in § 9.02
and § 9.03, the information below shall be shown on the
plans for all minor subdivision applications.
A. If final approval is granted after the construction of public improvements,
and the design of said improvements after construction is different
than shown on the plans for preliminary approval, those items required
for preliminary major subdivisions pursuant to § 9.06, shown
in final form.
B. Information sufficient to demonstrate that all of the conditions
of preliminary approval have been satisfied.
D. Location and description of existing and proposed monuments, including
monuments where found, monuments set or reset, and monuments to be
set or reset.
E. Reference meridian for north arrow shown graphically.
G. Certification from a licensed surveyor as to the accuracy of the
details on the plat and as to compliance with provisions of the Map
Filing Law.
H. Certification from a licensed surveyor as to the setting of monuments
or from the Town Clerk as to the posting of a bond for the future
setting of monuments.
I. Certification from the Town Engineer as to the plat's compliance
with the provisions of the Map Filing Law and all applicable Town
ordinances and requirements.
J. A statement from the Town Engineer that he has received a map showing
all utilities in exact location and elevation identifying those portions
already installed and those to be installed, and that the developer
has installed all improvements in accordance with all Town regulations,
and/or a statement by the Town Clerk that proper performance guarantees
have been posted with the Town Council for the installation of required
improvements.
K. A developer
of affordable housing shall incorporate on the plan a table identifying
the location, required bedroom distribution, and intended occupancy
(low- or moderate-income) of all affordable units, in compliance with
the Uniform Housing Affordability Controls set forth in N.J.A.C. 5:80-26.1.
[Added 4-28-2020 by G.O. No. 2165]
In addition to the requirements indicated in § 9.02
and § 9.03, the following information shall be submitted
for all minor site plans:
A. Location of existing and proposed parking, loading, access and circulation
improvements, signs, exterior lighting and landscaping.
B. If interior renovations or alterations are proposed, floor plans
for existing and proposed buildings, showing the use and layout of
internal space, at a scale consisting of no more than eight feet per
inch.
C. If alterations to the existing building facade are proposed, elevations
showing the extent and nature of the construction.
D. If revisions to existing topographic contours or spot elevations
are proposed, or if the building entrance or finished floor elevation
is proposed to be revised, existing and proposed contours and/or spot
elevations portraying the change.
In addition to the requirements indicated in § 9.02
and § 9.03, the following information shall be submitted
for all preliminary major site plans:
A. Location of existing and proposed buildings and their setbacks from
property lines, plus the location of existing buildings and paved
areas on adjacent properties.
B. Floor plans for existing and proposed buildings, showing the use
and layout of internal space, and front, rear and side building facade
elevations, both at a scale consisting of no more than eight feet
per inch.
C. Location and design of existing and proposed parking, loading, access
and circulation improvements, showing dimensions of same.
D. Existing and proposed topographic contours of the site and adjacent
areas affecting the site. Contour intervals shall be no greater than:
10% grade or less, two feet; over 10% grade, five feet. Contour elevations
shall be referenced to the New Jersey Geodetic Control Survey datum.
E. If new buildings or paved areas are proposed, or if regrading near
existing buildings is proposed, proposed spot grades at the corners
of all buildings and in appropriate pavement locations, and finished
floor elevations.
F. Existing and proposed utility service, including any existing septic
systems, connections to sanitary sewers, wells, connections to water
mains, fire hydrants, etc.
G. Existing and proposed storm drainage design and improvements, including
a map showing the entire drainage area, the drainage area contributing
to each pertinent drainage structure and drainage tabulation sheets
showing calculations for each drainage area. Provisions for rooftop
drainage shall also be shown.
H. Existing and proposed site illumination, including height and location
of fixture, type of fixture and bulb, pole material, and manufacturer's
isocandela diagram superimposed upon the site plan.
I. Location and description of existing and proposed landscaping. Information
for proposed landscaping shall include common and scientific names,
number of plants, planted size and root specification.
J. Existing and proposed signs, including the size, materials, nature
of construction, location and any illumination of same.
K. The location and design of fences, walls, sidewalks and similar improvements
to be proposed.
L. The location and design of solid waste disposal containers and recycling
containers.
M. If development is proposed in phases or stages, a phasing plan.
N. A developer
of affordable housing shall incorporate on the plan a table identifying
the location, required bedroom distribution, and intended occupancy
(low- or moderate-income) of all affordable units, in compliance with
the Uniform Housing Affordability Controls set forth in N.J.A.C. 5:80-26.1
[Added 4-28-2020 by G.O. No. 2165]
In addition to the requirements indicated in § 9.02
and § 9.03, the following information shall be submitted
for all final major site plans:
A. If final approval is granted after the construction of public improvements,
and the design of said improvements after construction is different
than shown on the plans for preliminary approval, those items required
for preliminary major site plans pursuant to § 9.09, shown
in final form.
B. Information sufficient to demonstrate that all of the conditions
of preliminary approval have been satisfied.
C. A developer
of affordable housing shall incorporate on the plan a table identifying
the location, required bedroom distribution, and intended occupancy
(low- or moderate-income) of all affordable units, in compliance with
the Uniform Housing Affordability Controls set forth in N.J.A.C. 5:80-26.1.
[Added 4-28-2020 by G.O. No. 2165]
All applications or appeals for a "C" variance or "D" variance,
when site plan or subdivision approval is not required, or when the
variance application has been bifurcated from subsequent site plan
or subdivision applications which may be required by this ordinance,
shall submit the information required by § 9.02 and § 9.03.
The Board reviewing the application shall have the authority to request
additional information not required by § 9.02 and § 9.03,
if in its opinion, such additional information is necessary to make
an informed decision on the application or appeal.
[Amended 11-12-2019 by G.O. No. 2150]
Applications or appeals for other than variance relief shall
be required to submit the information specified in the procedural
sections for said appeals, § 7.01E.2, § 7.01F.2,
§ 7.02B.2 and 3, or § 7.02C.1 through 3, as appropriate.
In addition, a digital copy in PDF format of the information specified
shall be submitted.
[Added 9-22-2020 by G.O. No. 2189]
A. In addition to the requirements indicated elsewhere in this article,
all applications for preliminary and final major subdivision approval
and preliminary and final major site plan approval shall complete
and submit the following Green Development Checklist. Failure to do
so will render the application incomplete. While completion of the
checklist is mandatory, it is for information purposes only, and compliance
with the items found herein will not become a condition of approval.
B. The checklist includes various green development design strategies
that can be implemented as part of a residential or commercial development.
The information provided in the checklist will guide and inform the
dialogue between an applicant and the Town regarding possible options
and opportunities to use resources more efficiently, promote smart
economic development, improve the environment, and generally improve
the quality of life in the Town.
C. The checklist is organized into three sections: first, it addresses
the site within its regional and local context, looking at its physical
location, development status, and availability of certain infrastructure;
second, it addresses the impact of the proposed development on the
site itself; and third, it addresses the structures on the site.
D. The applicant should provide examples of how they meet or address
each of the items in the checklist.
|
Yes
|
No
|
Comments
|
---|
Section A. Context
|
|
|
|
1.
|
Is the site a redevelopment or brownfield site?
|
|
|
|
2.
|
Is the site served by public transit, or easily accessible on
foot or by bicycle?
|
|
|
|
3.
|
Is there train service within 1/2 mile or bus service within
1/4 mile?
|
|
|
|
4.
|
Are the roads within the development designed as "Complete Streets?"
(which serve all users not only motorists)
(Examples: sidewalks, enhanced crosswalks, traffic calming,
bike lanes, transit shelters)
|
|
|
|
5.
|
Does the development include historic preservation, or adaptive
reuse of existing facilities?
|
|
|
|
6.
|
Does the site's location, scale or use support the historic
context of surrounding historic properties?
|
|
|
|
7.
|
Does the development provide or enhance the following:
|
|
|
|
|
a)
|
A mix of land use types? Please list.
|
|
|
|
|
b)
|
Housing diversity by type and income?
|
|
|
|
|
c)
|
Civic & public spaces or have proximity to them? (Examples:
open plazas, courtyards, public art)
|
|
|
|
|
d)
|
Recreation facilities and green space/parks (or have proximity
to them) and is it part of an integrated network?
|
|
|
|
|
e)
|
Alternative parking designs such as reduced parking ratios,
compact stalls, banked parking, shared parking, priority parking for
low-emission vehicles and provisions for bicycle storage and electric
vehicle charging stations?
|
|
|
|
|
f)
|
Access to or partnerships with local farms or farmers' markets
to promote local food production?
|
|
|
|
|
g)
|
Open space?
|
|
|
|
|
h)
|
Natural features such as rivers, streams, shorelines, wetlands,
forests, or wildlife habitats?
|
|
|
|
|
i)
|
Pedestrian access to waterfronts?
|
|
|
|
|
j)
|
Regional stormwater management? (A regional stormwater management
plan addresses stormwater-related water quality and water quantity
impacts of new and existing land uses on a drainage area basis and
is not limited to on-site stormwater management measures.)
|
|
|
|
|
Yes
|
No
|
Comments
|
---|
Section B. Site Development
|
|
|
|
1.
|
Does the design provide for the following:
|
|
|
|
|
a)
|
Minimum site disturbance during construction? [SJ]
|
|
|
|
|
b)
|
Increased erosion and sedimentation control beyond county or
municipal requirements?
|
|
|
|
|
c)
|
Low-impact design features such as:
|
|
|
|
|
|
▪
|
Bio-swales
|
|
|
|
|
|
▪
|
Rain gardens
|
|
|
|
|
|
▪
|
Green roofs
|
|
|
|
|
|
▪
|
Pervious pavements
|
|
|
|
|
|
▪
|
Green walls (Also known as vertical gardens, they are designed
and engineered for maximum biofiltration of indoor air, thermal regulation
and aesthetics.)
|
|
|
|
|
|
▪
|
Trees (beyond that required by the ordinance)
|
|
|
|
|
|
▪
|
Indigenous plant species (non-invasive species, low-maintenance
landscaping)
|
|
|
|
|
|
▪
|
Onsite management of vegetative waste
|
|
|
|
|
d)
|
Regenerative design?
|
|
|
|
|
|
▪
|
Does the site design conserve habitat, wetlands or water bodies?
|
|
|
|
|
|
▪
|
Does the site design include restoration of habitat, wetlands
or water bodies?
|
|
|
|
|
|
▪
|
Does the project include long-term conservation management of
habitat, wetlands or water bodies?
|
|
|
|
2.
|
Does the site minimize heat island effects through reduced paving,
enhanced landscaping, green roofs, or other methods?
|
|
|
|
3.
|
Does the site provide alternatives to single-occupancy vehicles
such as van spaces, bike storage and changing facilities, and alternative
energy vehicle parking and charging facilities?
|
|
|
|
4.
|
Does the site include light pollution reduction techniques that
help prevent misdirected or excessive light to reduce glare, light
trespass, and sky-glow?
|
|
|
|
5.
|
Does the site include energy efficient site lighting and controls?
|
|
|
|
6.
|
Have steps been taken to limit disruption of natural hydrology
by reducing impervious cover or increasing on-site infiltration?
|
|
|
|
7.
|
On sites adjacent to waterways, have slopes and existing vegetation
been stabilized and protected?
|
|
|
|
8.
|
Do the landscape and stormwater management specifications employ
integrated pest management practices? (IPM takes advantage of all
appropriate pest management options including, but not limited to,
the judicious use of pesticides.)
|
|
|
|
|
Yes
|
No
|
Comments
|
---|
Section C. Green Building
|
|
|
|
1.
|
Does the building(s) meet any criteria for a certified green
building?
(A green building, also referred to as sustainable or high-performance
building, is a collection of better design, construction, and operating
practices that have the potential to reduce or eliminate the negative
impacts of development on the environment and on human health. Green
building programs and guidelines commonly address energy efficiency
and carbon emissions reduction, water conservation, waste reduction,
healthy and sustainably produced materials, indoor air quality, occupant
productivity and health, and other components of green building. For
more info visit: http://rcgb.rutgers.edu or https://new.usgbc.org/leed)
|
|
|
|
2.
|
Is the building oriented to maximize the benefits of daylighting
and energy conservation and minimize any detrimental impacts on surrounding
sites?
(Example: Maximize southern building exposure for solar energy,
orient building to minimize effects of cold winter winds and maximize
cool summer breezes. Minimize shadows on open space and other buildings.)
|
|
|
|
3.
|
Water reduction
|
|
|
|
|
a)
|
Does the building provide a 20% or greater reduction beyond
minimum water efficiency standards set by the EPA or local government,
whichever is greater? http://www.epa.gov/watersense
|
|
|
|
|
b)
|
Does the building employ water conservation features including
low-flow fixtures, waterless urinals, or sensor-controlled faucets?
|
|
|
|
|
c)
|
Does the building capture and reuse rainwater, gray water or
storm water?
|
|
|
|
|
d)
|
Is wastewater treated onsite and recharged to the ground?
|
|
|
|
4.
|
Energy
|
|
|
|
|
a)
|
Does the building reduce energy usage through efficient heating
and cooling, geothermal technology, enhanced daylighting, efficient
lighting, occupant controls and an efficient building envelope?
|
|
|
|
|
b)
|
Does the project incorporate ENERGY STAR®-labeled building products?
|
|
|
|
|
c)
|
Does the building include onsite energy generation, e.g. solar
or wind?
|
|
|
|
|
d)
|
What is the anticipated energy savings expected to be realized
from any or all of the above?
|
|
|
|
|
e)
|
What are the anticipated carbon emission reductions?
|
|
|
|
5.
|
Indoor air quality
|
|
|
|
|
a)
|
Does the building utilize natural ventilation and efficient
use of outdoor air during heating and cooling periods?
|
|
|
|
|
b)
|
Are other measures such as reducing the quantity of VOCs from
adhesives, sealants, paints, composite wood systems and carpet systems
being used to improve indoor air quality?
|
|
|
|
6.
|
Materials
|
|
|
|
|
a)
|
Is an existing building being reused? If so, to what extent
- 100%, 75%, 50%?
|
|
|
|
|
b)
|
Are there waste management/recycling plans in place to divert
construction, demolition and land clearing debris from landfill disposal?
|
|
|
|
|
c)
|
Are any building materials reused on or off-site?
|
|
|
|
|
d)
|
Do new building materials contain recycled content? If so, to
what extent (%)?
|
|
|
|
|
e)
|
Are building materials extracted, processed or manufactured
locally or within the region (within a 500-mile radius)?
|
|
|
|