A. 
The following zoning districts are hereby established to regulate the orderly use and development of all lands within the Borough. The specific purpose of each district shall serve as guidance for regulating existing and future development. All land within the Borough is classified as one of the following zoning districts hereby established and designated on the Zoning Map as follows:
Zoning District
Abbreviation
Residential - Alley-Loaded
R-A
Residential - Street-Loaded
R-S
Residential - Collector Streets
R-C
Commercial District
C
Transit-Oriented District
TO
Public Amenity
PA
B. 
The Planned Residential Development District (PRD) is no longer included in the menu of zoning districts in this code. All property previously designated as a PRD that is not assigned a different zoning district concurrently with the adoption of this code shall remain a PRD and may continue to function under the established standards of each specific PRD ordinance previously adopted. Any project within the same geographic boundaries of an existing PRD may be redeveloped under the same provisions that were previously adopted for that district or according to an appropriate zoning district herein.
C. 
Zoning Map.
210-3-big.tiff
The following diagram illustrates the lot, building placement and height standards set forth in each zoning district.
210-4.tif
Lot Dimensions
D
Lot depth (feet)
W
Lot width (feet)
Lot Setbacks
F
Front yard setback (feet)
S
Side street yard setback (feet)
S
Side yard setback (feet)
R
Rear yard setback (feet)
Height and Coverage
H
Number of stories
Principally permitted, conditional, and special exception uses are listed in the use table below.[1] The following symbols are used in the table and are defined as follows:
Symbol
Definition
P
Permitted principal use: A use is permitted in the zoning district as a principal use. The use is also subject to all other applicable requirements of this code.
PC
Permitted principal use with conditions: Certain permitted principal uses are permitted subject to applicable specific requirements.
SE
Special exception use: A principal use is permitted by special exception only where approved by the Zoning Hearing Board in accordance with a hearing to determine whether it meets the special exception standards for approval set forth herein.
PA
Permitted accessory use: An accessory use may be permitted as an accessory use to a principal use. Permitted accessory uses are subject to all other applicable requirements of this code.
PAC
Permitted accessory use with conditions: Certain permitted accessory uses are permitted subject to applicable specific requirements.
(Blank)
Use not permitted: A use is not permitted in the district. Uses not listed as a permitted principal use (P), permitted principal use with conditions (PC), permitted accessory use (PA), conditional principal use (C), conditional accessory use (CA), or special exception (SE) are prohibited in the applicable zoning district.
[1]
Editor’s Note: The Summary Use Table is included in § 210-205.
A. 
The Borough will occasionally receive an application for approval of a use that is not expressly listed in the use table. In such instances, the Borough Manager or their designee will determine if a proposed use is similar to a listed use based on the following factors:
(1) 
Whether the proposed use is consistent with the Comprehensive Plan or area plan and the purpose and intent of the zoning district;
(2) 
Whether the use has similar impacts on the surrounding neighborhood, such as traffic, noise, lighting, or similar considerations; and
(3) 
Whether the use has the same characteristics as a listed use in terms of building and site arrangement, site area or floor space, equipment devoted to the activity, customer type, number of employees in each activity, hours of operation, vehicles used and parking requirements, number of vehicle trips generated, signs, and how the use is advertised.
B. 
If it is determined that a proposed use is similar to a listed use, the regulations governing the similar listed use apply to the unlisted use.
C. 
If it is determined that a proposed use is not similar to a listed use, then the proposed use shall be prohibited. The decision of the Borough Manager or their designee is appealable to the Zoning Hearing Board as set forth herein below.
Zoning District
Uses
Transit-Oriented (TO)
Commercial (C)
Residential Alley-Loaded (R-A)
Residential Street-Loaded (R-S)
Residential Collector Streets (R-C)
Public Amenities (PA)
Key
P = Permitted Use;
PC = Permitted Use with Conditions
SE = Special Exception
PA = Permitted Accessory Use
CA = Conditional Accessory Use
PAC = Permitted Accessory Use with Conditions
Blank = Not Permitted
Residential Uses
Group care facility
SE
SE
SE
SE
Group home
SE
SE
SE
SE
Nursing home
SE
SE
Personal care boarding home
SE
SE
SE
Residential (1-2 units)
P
P
PC (not permitted on corner lots)
Residential (2-5 units)
PC (on upper floors only)
PC (on upper floors only)
PC (on corner lots only)
PC (on corner lots only)
P
Residential (6+ units)
PC (whole building use permitted where 24 or more units)
PC (on upper floors only)
P
Senior independent-living facility
SE
SE
P
Senior assisted-living facility
SE
SE
SE
Skilled-care facility
SE
SE
SE
Transitional dwelling
SE
SE
SE
SE
SE
Commercial Uses
Adult entertainment business
SE
Antique shop
P
PC (ground floor only)
Art studio
P
P
PAC (accessory structure only)
PAC (accessory structure only)
PC (ground floor only)
Artisan manufacturing
PA
PA
PAC (accessory structure only)
PAC (accessory structure only)
PAC (accessory structure only)
Beverage sales, liquor, beer or wine store
P
P
Beverage, brewing and distilling
PC
PC
Beverage, distribution
P
P
Beverage, nonalcoholic production
P
P
Car wash
SE
Clinic, veterinary
SE
P
PAC (ground floor only)
Drugstore
PAC (on first floor of mixed-use building only; no standalone drugstore buildings permitted)
PAC (on first floor of mixed-use building only; no standalone drugstore buildings permitted)
Financial institution
P
P
Food sales, large grocery
PAC (on first floor of mixed-use building only; no standalone grocery buildings permitted)
PAC (on first floor of mixed-use building only; no standalone grocery buildings permitted)
Food sales, small grocery
P
P
PC (permitted on first floor of mixed-use building only; convenience stores not permitted unless 10% of sales are fresh produce/fruit)
Food service, commissary/bakery
P
P
PC (permitted on first floor of mixed-use building only)
Food service, deli
P
P
PC (permitted on first floor of mixed-use building only)
Funeral home
SE
SE
Garden center
SE
Indoor storage facility
SE
SE
Kennel
SE
Light manufacturing
SE
Motorcycle sales and service
SE
Offices, business and professional
P
P
PAC (home occupation only; public appointments in accessory structure or separate entrance only)
PAC (home occupation only; public appointments in accessory structure or separate entrance only)
PAC (home occupation only; public appointments in accessory structure or separate entrance only)
Outdoor storage facility
Overnight lodging, bed-and-breakfast
P
SE
SE
P
Overnight lodging, boutique hotel
SE
P
Overnight lodging, hotel
P
P
Overnight lodging, private transient occupancies
P
P
PAC (limited to not more than 25% of calendar year)
PAC (limited to not more than 25% of calendar year)
PAC (limited to not more than 25% of calendar year)
Personal services
P
P
PAC (home occupation only; public appointments in accessory structure only)
PAC (home occupation only; public appointments in accessory structure only)
PAC (home occupation only; public appointments in accessory structure only)
Research/laboratory facility
P
P
Restaurant, full service
P
P
PC (permitted on first floor of mixed-use building only)
Restaurant, limited service
P
P
PC (permitted on first floor of mixed-use building only)
Restaurant, quick service
P
P
PC (permitted on first floor of mixed-use building only)
Retail gasoline and convenience
SE
SE
Retail store
P
P
PC (permitted on first floor of mixed-use building only)
Vehicle repair garage
SE
Vehicle sales and service
SE
SE
Warehouse
SE
Wholesale sales
P
Health and Wellness
Clinic
P
P
PAC (home occupation only; public appointments in accessory structure only)
PAC (home occupation only; public appointments in accessory structure only)
PAC (home occupation only; public appointments on first floor of mixed-use building only)
Fitness facility/gym
P
P
PA
Hospital
SE
Message and physical therapy
P
P
PAC (home occupation only; public appointments on first floor of mixed-use building only)
Standalone emergency facility
SE
Urgent care
P
P
Public Uses
Cemetery
SE
Collection and recycling facility
SE
Government administration
P
P
P
Park
P
P
P
P
P
P
Public parking garage
P
P
Public parking lot
P (interior of lot only; none directly adjacent to existing right-of-way)
P
PA
Public safety facility
P
P
P
Public utility building
P
P
P
Utility generation facility
SE
SE
Congregate Uses
Arts center
P
P
P
P
Community center
P
P
P
P
Event center
P
P
P
Library
P
P
P
P
Private club
P
P
SE
P
Religious assembly
SE
PC (standalone buildings only with on-site parking for at least 10 personal vehicles)
PC (standalone buildings only with on-site parking for at least 10 personal vehicles)
Theater
P
P
P
Recreation
Commercial recreation, indoor
SE
SE
Commercial recreation, outdoor
SE
Community park
P
P
P
P
P
P
Education and Childcare
Commercial college
P
P
Day-care center
P
PC (first floor of mixed-use building only)
PC (first floor of mixed-use building only)
P
Day-care home
PAC (home occupation only)
PAC (home occupation only)
PAC (home occupation only)
PAC (home occupation only)
PAC (home occupation only)
Nursery school
PC (first floor of mixed-use building only)
PC (first floor of mixed-use building only)
PC (first floor of mixed-use building only)
P
School
P
P
School, college/university
P
P
Accessories
Accessory dwelling unit (ADU)
P
P
P
P
No-impact home-based business
PA
PA
PA
PA
PA
Private garage
P
P
P
P
P
Private parking lot
PC (structured parking only)
PC (rear yard only)
PC (rear yard only)
PC (rear yard only)
PC (rear yard only)
Small farm animal keeping
PAC (rear yard only; fully fenced yard only; no roosters)
PAC (rear yard only; fully fenced yard only; no roosters)
PAC (rear yard only; fully fenced yard only; no roosters)
P
Solar facility
PC (rooftop only)
PC (rooftop only)
PC (rooftop only)
PC (rooftop only)
PC (rooftop only)
P
Swimming pool
P
P
P
P
P
P
Walk-up/bike-up window
PC (front or side elevation only; one 1 square foot menu board per window)
PC (front or side, elevation only; one 1 square foot menu board per window)
PC (front or side elevation only; one 1 square foot menu board per window)
PC (front or side elevation only; one 1 square foot menu board per window)
Communications Facilities
Essential communications facility
SE
SE
Temporary Uses
Construction trailer
PC (for duration of active construction only; rear yard only)
PC (for duration of active construction only; rear yard only)
PC (for duration of active construction only; rear yard only)
PC (for duration of active construction only; rear yard only)
PC (for duration of active construction only; rear yard only)
P
Farmers’ market
PC (outdoor only April through October; not more than 2 days per week. Indoor allowed November through March)
PC (outdoor only April through October; not more than 2 days per week. Indoor allowed November through March)
PC (outdoor only April through October; not more than 2 days per week. Indoor allowed November through March)
PC (outdoor only April through October; not more than 2 days per week. Indoor allowed November through March)
210-5.tiff
A. 
Intent. The Transit-Oriented (TO) District recognizes that Dormont’s three rail transit stations are valuable assets and amenities for the Borough and desires to leverage them by creating a vibrant mixed-use locus around each station. Development around transit promotes transit usage, walkability, and reduces automobile dependence and traffic congestion.
B. 
Development pattern. The intended development pattern and building form within the TO District is for vertical buildings of three to eight stories, with small or no setbacks and with off-street parking subordinated in structures or in the rear or interior courts of buildings. Buildings are to be oriented to promote pedestrian access to transit stations and surrounding walkable commerce and amenities. Corner buildings should include commercial uses at the ground level with residential uses above.
210-7.tiff 210-9.tiff
210-8.tiff
210-10.tiff 210-11.tiff 210-12.tiff 210-16.tiff
210-13.tiff 210-14.tiff 210-15.tiff
C. 
Site development standards.
210-17.tif
Lot Setbacks
Minimum
Maximum
F
Front yard setback (feet)
15, with outdoor dining
R
Rear yard setback (feet)
7
Height and Coverage
Minimum
Maximum
H
Number of stories
2
8
C
Commercial ground floor
20%
Surface Parking
P
Location
Rear or side yard
D. 
General Transit-Oriented District design standards.
(1) 
Building design.
Ground Floor, Street Facing
Height (feet)(minimum/maximum)
12/20
Openings
Minimum of 40% transparency for residential; 75% for commercial
Facade materials
Finish-quality wood, fiber cement board, brick, stone, polished concrete, cast iron or similar metal
Upper Floors, Street Facing
Openings
Required
Facade materials
Fiber cement board, brick, stone, cast iron or similar metal
Facade articulation
No facade shall be longer than 180 feet without a plane change of 3 or more feet
(2) 
Landscape design.
Fences, Walls and Gates
Not permitted
Landscaping Required
Plan required
Yes
Front yard tree
Yes, 3 feet or closer to the right-of-way line if front yard setback is greater than 10 feet
Foundation plantings
Yes
Service Area Screening
Height (feet)(minimum/maximum)
6/8
Location
Rear yard
Setback (minimum)
5 feet from any lot line
Materials
Treated and stained or painted wood or brick
Clear area (minimum)
10 feet in front of enclosure doors
Dumpsters (maximum)
2 per principal building
(3) 
Parking design.
General Criteria
Drive aisle size (feet)(minimum/maximum)
12/14
Connection to other parking facilities
Permitted
Maximum number of curb cuts per frontage
1
Service and loading
Rear of building
Drive-throughs
Not permitted
Lighting and Landscape
Lighting locations
Interior and edge required
Curbs
Required
Edge landscape
Required
Interior landscaping
Permitted (curb required)
Parking Structures
Front yard setback (minimum)
40 feet
Side and rear yard setbacks (minimum)
40 feet
Height (maximum)
6 stories; not taller than immediately surrounding building
Facade articulation
No facade shall be longer than 180 feet without a plane change of 3 or more feet
Design standards
Facade of natural materials similar in design and materials to majority of buildings in development or neighborhood within 300-foot radius of parking structure
(4) 
Permitted sign types (See Article V for specific requirements.): wall (including marquee); projecting; roof; window; painted mural; sandwich board; awning; temporary; access; entranceway.
Note: Inclusionary zoning requirements apply to new construction of 15 or more dwelling units in the TO District. (See Article V for specific requirements.)
210-18.tiff
A. 
Intent. The Commercial (C) District is located along the main commercial corridors of West Liberty Avenue and Potomac Avenue.
B. 
Development pattern. The predominant development pattern and building form in these districts should promote a diversity of commercial uses on the ground floor with residential uses on the upper floors. Buildings should be vertical and of two to six stories with little to no setbacks, off-street parking located in the rear, if at all, and buildings designed and oriented toward the street to promote a walkable environment of small-footprint retail, services, food and entertainment uses.
C. 
Uses. The mix of uses in the C District is intended to promote Dormont as a twenty-minute neighborhood where most essential neighborhood amenities are no more than a twenty-minute walk from any part of the Borough.
210-20.tiff 210-22.tiff
210-21.tiff
210-23.tiff 210-24.tiff 210-25.tiff 210-29.tiff
210-26.tiff 210-27.tiff 210-28.tiff
D. 
Site development standards.
210-30.tif
Lot Setbacks
Minimum
Maximum
F
Front yard setback (feet)
15, with outdoor dining
SY
Side yard setback (aggregate) (feet)
12
R
Rear yard setback (feet)
7
Accessory Building
Location
Rear yard; minimum setback is 3 feet from rear/side lot line
Number of stories (maximum)
2
Height and Coverage
Minimum
Maximum
H
Number of stories
1
6
C
Commercial ground floor
75%
Surface Parking
P
Location
Rear yard
E. 
General Commercial District design standards.
(1) 
Building design.
Ground Floor, Street Facing
Height (feet)(minimum/maximum)
12/20
Openings
Minimum of 75% transparency
Facade materials
Finish-quality wood, fiber cement board, brick, stone, polished concrete, cast iron or similar metal
Upper Floors, Street Facing
Openings
Required
Materials
Fiber cement board, brick, stone, cast iron or similar metal
Facade articulation
No facade shall be longer than 180 feet without a plane change of 3 or more feet
(2) 
Landscape design.
Fences, Walls and Gates
Height (maximum)
8 feet (side and rear yards)
Opacity
100%
Materials
Iron, wood, metal (non-chain-link) with split rail fence only
Landscaping Required
Plan required
Yes
Front yard tree
Yes, 3 feet or closer to the right-of-way line
Foundation plantings
Yes
Service Area Screening
Height (feet)(minimum/maximum)
6/8
Location
Rear
Setback (minimum)
5 feet
Materials
Wood or brick
Clear area (minimum)
10 feet
Dumpsters (maximum)
1
Retaining walls
Plan required
(3) 
Parking design.
General Criteria
Drive aisle size (feet)(minimum/maximum)
12/14
Connection to other parking facilities
Permitted
Maximum number of curb cuts per frontage
1
Service and loading
Rear of building
Drive-throughs
Not permitted
Lighting and Landscape
Lighting locations
Interior required, edge not permitted
Materials
Asphalt, pervious pavers, concrete
Curbs
Required
Edge landscape
Required
Interior landscaping
Permitted (curb required)
Parking Structures
Front yard setback (minimum)
40 feet
Side and rear yard setbacks (minimum)
40 feet
Height (maximum)
4 stories
Facade articulation
No facade shall be longer than 180 feet without a plane change of 3 or more feet
Design standards
Facade of natural materials similar in design and materials to majority of buildings in development or neighborhood within 300-foot radius of parking structure
(4) 
Permitted sign types (See Article V for specific requirements.): wall (including marquee); projecting; roof; window; painted mural; sandwich board; awning; temporary; access; entranceway.
210-31.tif
A. 
Intent. The Residential Collector (R-C) District is located along highly traveled residential corridors.
B. 
Development pattern. The predominant development pattern and building form along these corridors is intended to promote a mix of high- and medium-intensity building forms and uses. Corner buildings are intended to be situated and designed to create nodes of ground floor commercial uses with residential uses above.
210-33.tiff 210-35.tiff
210-34.tiff
210-36.tiff 210-37.tiff 210-38.tiff
210-39.tiff 210-40.tiff 210-41.tiff
C. 
Site development standards.
210-42.tif
Lot Dimensions
Minimum
Maximum
A
Lot size (square feet)
27,500
W
Lot width (feet)
60
Height and Coverage
Minimum
Maximum
H
Number of stories
2
4
L
Lot coverage (aggregate)
60% for lots of widths 30 feet or greater; 90% for lots 30 feet wide or less
L
Lot coverage (building only)
40% for lots of widths 30 feet or greater; 60% for lots 30 feet wide or less
Lot Setbacks
Minimum
Maximum
F
Front yard setback (feet)
15
SY
Side yard setback (aggregate) (feet)
8
Accessory Building
Location
Rear yard; minimum setback is either 3 feet from right-of-way line or 26 feet from the closest structure across alley
Number of stories (maximum)
2
Surface Parking
P
Location
Rear or side yard
D. 
General Residential Collector District design standards.
(1) 
Building design.
Ground Floor, Street Facing
Height (feet)(minimum/maximum)
11/16
Openings
Minimum of 40% transparency for residential; 60% for commercial
Facade materials
Finish-quality wood, fiber cement board, brick, stone
Upper Floors, Street Facing
Openings
Required
Facade materials
Fiber cement board, brick, stone
Facade articulation
No facade shall be longer than 120 feet without a plane change of 3 or more feet
(2) 
Landscape design.
Fences, Walls and Gates
Height (maximum)
6 (side and rear yards)
Opacity
75% (side and rear yards)
Materials
Chain-link (vinyl coated), iron; wood, synthetic (vinyl), metal (non-chain-link) with split rail fence only
Landscaping Required
Plan required
Yes
Front yard tree
Yes, 3 feet or closer to the right-of-way line
Foundation plantings
Yes
Service Area Screening
Height (feet)(minimum/maximum)
6/8
Location
Rear
Setback (minimum)
5 feet
Materials
Wood or brick
Clear area (maximum)
5 feet (minimum)
Dumpsters (maximum)
1
Retaining walls
Plan required
(3) 
Parking design.
General Criteria
Driveway width (feet)(minimum/maximum)
10/14; 8 maximum at curb
Connection to other parking facilities
Yes
Maximum number of curb cuts per frontage
1
Service and loading
Rear of building
Drive-throughs
Not permitted
Lighting and Landscape
Lighting locations
Interior
Materials
Asphalt, pervious pavers, concrete
Curbs
Required
Edge landscape
Required
Interior landscaping
Permitted (curb required)
(4) 
Permitted sign types (See Article V for specific requirements.): freestanding (monument, with site plan only); wall (including marquee); projecting; painted mural; sandwich board; awning; entranceway.
210-43.tiff
A. 
Intent. The Alley-Loaded Residential (R-A) District is established for residential properties with vehicular access by way of rear alleys.
B. 
Development pattern.
(1) 
The predominant development pattern and building form in this district is two- and three-story, residential single- and-two-unit buildings with a small side yard setback and direct pedestrian access via a front walk leading to a front porch or stoop.
(2) 
Rear yards may contain garages or other accessory structures oriented toward the alley and providing a secondary means of access to the property. Properties have small front yards and larger rear yards between the primary structure and the rear yard accessory structure.
210-45.tiff 210-47.tiff
210-46.tiff
210-48.tiff 210-49.tiff 210-50.tiff 210-54.tiff
210-51.tiff 210-52.tiff 210-53.tiff
C. 
Site development standards.
210-55.tif
Lot Dimensions
Minimum
Maximum
A
Lot size (square feet)
9,000
W
Lot width (feet)
40
Height and Coverage
Minimum
Maximum
H
Number of stories
2
3
L
Lot coverage (aggregate)
60% for lots widths 30 feet or greater; 90% for lot widths less than 30 feet
L
Lot coverage (building only)
40% for lots of widths 30 feet or greater; 60% for lots 30 feet wide or less
Lot Setbacks
Minimum
Maximum
F
Front yard setback (feet)
Average of front yard setback of buildings on either side
10
SY
Side yard setback (aggregate) (feet)
8
Accessory Building
Location
Rear yard; minimum setback is either 3 feet from right-of-way line or 26 feet from the closest structure across alley
Number of stories (maximum)
2
Surface Parking
P
Location
Rear yard
D. 
General Alley-Loaded Residential District design standards.
(1) 
Building design.
Ground Floor, Street Facing
Height (feet)(minimum/maximum)
10/14
Openings
Doors and windows required for each unit
Materials
Finish-quality wood, fiber cement board, brick, stone
Upper Floors, Street Facing
Openings
Required
Materials
Fiber cement board, brick, stone
Facade articulation
No facade shall be longer than 44 feet without a plane change of 3 or more feet
(2) 
Landscape design.
Fences, Walls and Gates
Height (maximum)
6 (side and rear yards)
Opacity
75% (side and rear yards)
Materials
Chain-link (vinyl coated), iron, wood, synthetic (vinyl), metal (non-chain-link) with split rail fence only
Landscaping Required
Plan required
Yes
Front yard tree
No
Foundation planting
Yes
Service Area Screening
Height (feet)(minimum/maximum)
6/8
Dumpsters (maximum)
Not permitted
(3) 
Parking design.
General Criteria
Driveway width (feet)(minimum/maximum)
10/12; 8 maximum at curb
Connection to other parking facilities
Permitted
Maximum number of curb cuts per frontage
1 (curb cut on alley frontage only)
Lighting and Landscape
Materials
Asphalt, pervious pavers, concrete
(4) 
Permitted sign types. (See Article V for specific requirements.): wall (including marquee, with conditions); entranceway.
210-56.tif
A. 
Intent. The Street-Loaded Residential (R-S) District includes residential properties with vehicular access by way of side yard drives, if at all.
B. 
Development pattern. The predominant development pattern and building form in these districts is two- and three-story, residential single- and-two-unit buildings with a small or no side yard setback in one side yard and a more substantial side yard setback in the other side yard to accommodate a one-car-wide driveway. Front yards are relatively small, and rear yards may accommodate a detached accessory structure at the terminus of the driveway.
210-58.tiff 210-60.tiff
210-59.tiff
210-61.tiff 210-62.tiff 210-63.tiff 210-67.tiff
210-64.tiff 210-65.tiff 210-66.tiff
C. 
Site development standards.
210-68.tif
Lot Dimensions
Minimum
Maximum
A
Lot size (square feet)
12,000
W
Lot width (feet)
50
Height and Coverage
Minimum
Maximum
H
Number of stories
2
3
L
Lot coverage (aggregate)
60% for lots widths 30 feet or greater; 90% for lot widths less than 30 feet
L
Lot coverage (building only)
40% for lots of widths 30 feet or greater; 60% for lots 30 feet wide or less
Lot Setbacks
Minimum
Maximum
F
Front yard setback (feet)
Average of front yard setback of buildings on either side
15
SY
Side yard setback (aggregate) (feet)
12
Accessory Building
Location
Rear yard; minimum setback is either 3 feet from rear lot line or 18 feet from front lot line; side yard setback minimum is 3 feet
Number of stories (maximum)
2
Surface Parking
P
Location
Rear or side yard
D. 
General Street-Loaded Residential District design standards.
(1) 
Building design.
Ground Floor, Street Facing
Height (feet)(minimum/maximum)
10/14
Openings
Doors and windows required for each unit
Facade materials
Finish-quality wood, fiber cement board, brick, stone
Upper Floors, Street Facing
Openings
Required
Facade materials
Fiber cement board, brick, stone
Facade articulation
No facade shall be longer than 44 feet without a plane change of 3 or more feet
(2) 
Landscape design.
Fences, Walls and Gates
Height (maximum)
6 feet (side and rear yard)
Opacity
100% (minimum, side and rear yard)
Materials
Chain-link (vinyl coated), iron, wood, synthetic (vinyl), metal (non-chain-link) with split rail fence only
Landscaping Required
Plan required
Yes
Front yard tree
No
Foundation plantings
Yes
Service Area Screening
Height (feet)(minimum/maximum)
6/8
Dumpsters (maximum)
Not permitted
(3) 
Parking design.
General Criteria
Driveway width (feet)(minimum/maximum)
10/12; 8 maximum at curb
Connection to other parking facilities
Permitted
Maximum number of curb cuts per frontage
1
Lighting and Landscape
Materials
Asphalt, pervious pavers, concrete
(4) 
Permitted sign types (See Article V for specific requirements.): sandwich board; entranceway.
210-69.tif
A. 
Intent. The Public Amenity (PA) District includes publicly owned facilities, such as parks, recreation facilities, schools, life and safety services, and government offices.
B. 
Development pattern. Properties in the PA District are largely open space; however, where there are buildings, they should be oriented in such a way to maximize pedestrian connectivity within the community. This district contains no building standards.
C. 
Permitted sign types (See Article V for specific requirements): freestanding (monument); projecting; sandwich board; temporary; access; entranceway.