In addition to submittal requirements specified in article
28.05, division 1 of this code, the documentation described in sections
28.09.042 through
28.09.049 of this code shall be submitted, as applicable.
(1983 Code, sec. 6-80MM; Ordinance 2005-O0140, sec. 2, adopted 12/15/2005; Ordinance 2010-O0017, sec. 5,
adopted 3/4/2010; Ordinance
2011-O0042, sec. 6, adopted 5/31/2011; Ordinance 2012-O0055, sec. 3, adopted 6/7/2012; Ordinance 2016-O0072 adopted 5/12/16; Ordinance
2020-O0016 adopted 2/11/2020; Ordinance 2024-O0025 adopted 3/26/2024)
Shop drawings for fire protection systems shall
be submitted to indicate conformance with this code and the construction documents and shall be approved prior to the start of system installation. Shop drawings shall contain
all information as required by the referenced installation standards
in chapter 9 of the International Building Code, and shall be reviewed
by the fire marshal.
(1983 Code, sec. 6-80MM.1; Ordinance 2005-O0140, sec. 2, adopted 12/15/2005; Ordinance 2010-O0017, sec. 5,
adopted 3/4/2010; Ordinance
2012-O0055, sec. 3, adopted 6/7/2012; Ordinance 2016-O0072 adopted 5/12/16; Ordinance 2020-O0016 adopted 2/11/2020; Ordinance 2024-O0025 adopted 3/26/2024)
The construction documents shall show in sufficient
detail the location, construction, size and character of all portions
of the means of egress including the path of the
exit discharge to the public way in compliance with
the provisions of this code. In other than occupancies in Group R-3,
the construction documents shall designate the number
of occupants to be accommodated on every floor, and in all rooms and
spaces.
(1983 Code, sec. 6-80MM.2; Ordinance 2005-O0140, sec. 2, adopted 12/15/2005; Ordinance 2010-O0017, sec. 5,
adopted 3/4/2010; Ordinance
2012-O0055, sec. 3, adopted 6/7/2012; Ordinance 2016-O0072 adopted 5/12/16; Ordinance 2020-O0016 adopted 2/11/2020; Ordinance 2024-O0025 adopted 3/26/2024)
Construction documents for all buildings shall
describe the exterior wall envelope in sufficient
detail to determine compliance with this code. The construction
documents shall provide details of the exterior wall
envelope as required, including flashing, intersections with
dissimilar materials, corners, end details, control joints, intersections
at roof, eaves or parapets, means of drainage, water-resistive barrier
and details around openings. The construction documents shall include manufacturer's installation instructions that
provide supporting documentation that the proposed penetration and
opening details described in the construction documents maintain the weather resistance of the exterior wall envelope. The supporting documentation shall fully describe the exterior
wall system which was tested, where applicable, as well as
the test procedure used.
(1983 Code, sec. 6-80MM.3; Ordinance 2005-O0140, sec. 2, adopted 12/15/2005; Ordinance 2010-O0017, sec. 5,
adopted 3/4/2010; Ordinance
2012-O0055, sec. 3, adopted 6/7/2012; Ordinance 2016-O0072 adopted 5/12/16; Ordinance 2020-O0016 adopted 2/11/2020; Ordinance 2024-O0025 adopted 3/26/2024)
The construction documents submitted with the
application for permit shall be accompanied by a
site plan showing to scale the size and location of new construction
and existing structures on the site, distances from lot lines, the established street
grades and the proposed finished grades and, as applicable, flood hazard areas, floodways, and design flood
elevations; and it shall be drawn in accordance with an accurate
boundary line survey. In the case of demolition, the site plan shall show construction to be demolished and the location and
size of existing structures and construction that
are to remain on the site or plot. The building
official is authorized to waive or modify the requirement
for a site plan where the application for permit is
for alteration or repair or where
otherwise warranted.
(1983 Code, sec. 6-80MM.4; Ordinance 2005-O0140, sec. 2, adopted 12/15/2005; Ordinance 2010-O0017, sec. 5,
adopted 3/4/2010; Ordinance
2012-O0055, sec. 3, adopted 6/7/2012; Ordinance 2016-O0072 adopted 5/12/16; Ordinance 2020-O0016 adopted 2/11/2020; Ordinance 2024-O0025 adopted 3/26/2024)
At the time of application for a building permit for first-time
construction of a building upon a lot previously undeveloped with
buildings, and at other times as determined necessary by the building official, the applicant shall furnish a certificate,
prepared by a licensed surveyor, attesting to having performed a recent
survey of the subject lot, and having placed boundary line corner
stakes thereon. The property owner or building contractor shall be
responsible for boundary line corner stakes being in place at the
time of the first inspection by the building official. Said certificate
shall also state whether or not the subject lot lies within a special
flood hazard area as determined by the latest FEMA flood insurance
rate map (FIRM) for the City of Lubbock, in which case the applicant
must also follow procedures under section 39.05.009 of the Unified
Development Code (UDC). In all cases where it may appear to the building official that the proposed improvements will encroach
upon any easement or public way, or come within established
building lines, or affect setback requirements under any ordinance,
the building official is required to refer the application
for permit to the city engineer and/or the city planner, as applicable,
and secure their approvals before issuing a building permit.
(1983 Code, sec. 6-80MM.5; Ordinance 2005-O0140, sec. 2, adopted 12/15/2005; Ordinance 2010-O0017, sec. 5,
adopted 3/4/2010; Ordinance
2012-O0055, sec. 3, adopted 6/7/2012; Ordinance 2016-O0072 adopted 5/12/16; Ordinance 2020-O0016 adopted 2/11/2020; Ordinance 2024-O0025 adopted 3/26/2024)
Where balconies or other elevated walking surfaces have weather-exposed surfaces, and the structural framing is
protected by an impervious moisture barrier, the construction
documents shall include details for all elements of the impervious
moisture barrier system. The construction documents shall include manufacturer's installation instructions.
(Ordinance 2024-O0025 adopted 3/26/2024)
The construction documents shall provide the
information specified in section 1603.
(Ordinance 2024-O0025 adopted 3/26/2024)
Construction documents for relocatable buildings
shall comply with section 3113.