Minimum Yard Setbacks
| |||||||
---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimmum Lot Width
(feet)
|
Front
(feet)
|
Side
(feet)
|
Rear
(feet)
|
Maximum Building Height
(feet)
|
RB
|
43,5602
|
20
|
100
|
203
|
10
|
10
|
301
|
RD-1
|
43,5602
|
20
|
125
|
303
|
10
|
10
|
301
|
RF-2
|
43,5602
|
20
|
150
|
303
|
15
|
15
|
301
|
NOTES:
| ||||||||
1
|
Or 2 1/2 stories, whichever is
lesser.
| |||||||
2
|
A minimum lot area of 87,120 square
feet is required in RPOD Overlay District.
[Added 10-26-2000] | |||||||
3
|
One hundred feet along Routes 28 and
132.
|
Minimum Yard Setbacks
| |||||||
---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
(feet)
|
Side
(feet)
|
Rear
(feet)
|
Maximum Building Height
(feet)
|
RC
|
43,5602
|
20
|
100
|
203
|
10
|
10
|
301
|
RD
|
43,5602
|
20
|
125
|
303
|
15
|
15
|
301
|
RF-1
|
43,5602
|
20
|
125
|
303
|
15
|
15
|
301
|
RG
|
65,000
|
20
|
200
|
303
|
15
|
15
|
301
|
NOTES:
| ||||||||
---|---|---|---|---|---|---|---|---|
1
|
Or 2 1/2 stories, whichever is
lesser.
| |||||||
2
|
A minimum lot area of 87,120 square
feet is required in RPOD Overlay District.
[Added 10-26-2000] | |||||||
3
|
One hundred feet along Routes 28 and
132.
|
Minimum Yard Setbacks
(feet)
| |||||||
---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
|
Side
|
Rear
|
Maximum Building Height
(feet)
|
RC-1
|
43,5602
|
125
|
—
|
303
|
15
|
15
|
301
|
RF
|
43,5602
|
150
|
—
|
303
|
15
|
15
|
301
|
1
|
Or 2 1/2 stories, whichever is lesser.
| |||||||
2
|
A minimum lot area of 87,120 square feet is
required in RPOD Overlay District.
[Added 10-26-2000] | |||||||
3
|
One hundred feet along Routes 28 and 132.
|
Minimum Yard Setbacks
(feet)
| |||||||
---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
|
Side
|
Rear
|
Maximum Building Height
(feet)
|
RC-2
|
43,5602
|
20
|
100
|
203
|
10
|
10
|
301
|
1
|
Or 2 1/2 stories, whichever is
lesser.
| |||||||
2
|
A minimum lot area of 87,120 square
feet is required in RPOD Overlay District.
| |||||||
3
|
One hundred feet along Routes 28 and
132.
[Added 10-26-2000] |
Minimum Yard Setbacks
(feet)
| |||||||
---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
|
Side
|
Rear
|
Maximum Building Height
(feet)
|
RAH
|
43,560
|
125
|
—
|
30
|
15
|
15
|
301
|
RAH
|
10,0002,3
|
20
|
75
|
30
|
15
|
15
|
301
|
1
|
Or 2 1/2 stories, whichever is
lesser.
| |||||||
2
|
Provided that each dwelling is connected
to the municipal sewage collection system when the site is located
in a Groundwater Protection Overlay District.
| |||||||
3
|
As an alternative to individual lots,
more than one single-family dwelling may be constructed on a lot,
provided that the area of any such lot shall contain not less than
10,000 square feet of contiguous upland for each single-family dwelling
constructed. When more that one single-family dwelling is constructed
on a lot said dwelling shall be at least 30 feet apart.
|
Zoning District
|
Minimum Lot Area
(square feet)
|
Minimum Lot
Frontage (feet)
|
Minimum Lot Width
(feet)
|
Minimum Yard Setbacks
(feet)
|
Maximum Building Height1
(feet)
| ||
---|---|---|---|---|---|---|---|
Front
|
Side
|
Rear
| |||||
MAH
|
87,120
|
200
|
—
|
60
|
30
|
30
|
30
|
NOTES:
| ||
---|---|---|
1
|
Height shall be measured from the grade plane to the plate.
|
Minimum Yard Setbacks
(feet)
| ||||||
---|---|---|---|---|---|---|
Minimum
Lot Area
|
Minimum Lot Frontage
|
Minimum Lot Width
|
Maximum Building Height
| |||
(square feet)
|
(feet)
|
(feet)
|
Front
|
Side
|
Rear
|
(feet)
|
10,000
|
50; 20 for a lot on the radius of a
cul-de-sac
|
65 (1)
|
15(3)
|
10(4)
|
20(4)
|
30(5)
|
Notes:
| |
(1)
|
The Planning Board may grant a waiver
to the lot width requirement to individual lots located on the radius
of a cul-de-sac, provided that the grant of the waiver will result
in a proper alignment of the home to the street.
|
(2)
|
Accessory structures that require a
building permit shall be required to conform to all setback requirements.
|
(3)
|
Accessory garages, whether attached
or detached, shall require a minimum front yard setback of 20 feet.
|
(4)
|
The Planning Board may require a planted
buffer area within any required rear or side yard setback area.
|
(5)
|
Or 2 1/2 stories, whichever is
less.
|
Minimum Yard Setbacks
| |||||||
---|---|---|---|---|---|---|---|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front3
(feet)
|
Side
(feet)
|
Rear
(feet)
|
Maximum Building Height
(feet)
|
Maximum Lot Coverage as % of Lot Area
|
43,560
|
160
|
—
|
30
|
30
|
30
|
301
|
102
|
NOTES:
|
---|
1 Or two stories, whichever
is lesser
|
2 No more than 33% of the
total upland area of any lot shall be made impervious by the installation
of buildings, structures and paved surfaces.
|
3 Front yard landscaped setback from the road lot line: 20 feet. Existing trees and shrubs shall be retained within the road right-of-way and within the required front yard landscaped setback and supplemented with other landscape materials, in accordance with accepted landscape practices. Where natural vegetation cannot be retained, the front yard landscaped setback shall be landscaped with a combination of grasses, trees and shrubs commonly found on Cape Cod. A minimum of one street tree with a minimum caliper of three inches shall be provided per 30 feet of road frontage distributed throughout the front yard setback area. No plantings shall obscure site at entrance and exit drives and road intersections. All landscaped areas shall be continuously maintained, substantially in accordance with any site plan approved pursuant to Article IX herein.
|
Minimum Yard Setbacks
| ||||||||
---|---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
(feet)
|
Side
(feet)
|
Rear
(feet)
|
Maximum Building Height
(feet)
|
Maximum Lot Coverage as % of Lot Area
|
B
|
—
|
20
|
—
|
201
|
—
|
—
|
303
|
—
|
BA
|
—
|
20
|
—
|
20
|
—
|
—
|
303
|
35
|
UB
|
—
|
20
|
—
|
202
|
02
|
02
|
303
|
35
|
NOTES:
| |||||||||
---|---|---|---|---|---|---|---|---|---|
1
|
One hundred feet along Routes 28 and
132.
| ||||||||
2
|
Fifty feet when abutting a residentially
zoned area.
| ||||||||
3
|
Or two stories, whichever is lesser.
| ||||||||
Front yard landscaped setback from
the road lot line:
B Business District: 10 feet, except
50 feet along Attucks Lane Extension and Independence Drive.
BA District: 10 feet.
UB District: 10 feet.
Existing trees and shrubs shall be retained within the road right-of-way and within the required front yard landscaped setback and supplemented with other landscape materials, in accordance with accepted landscape practices. Where natural vegetation cannot be retained, the front yard landscaped setback shall be landscaped with a combination of grasses, trees and shrubs commonly found on Cape Cod. A minimum of one street tree with a minimum caliper of three inches shall be provided per 30 feet of road frontage distributed throughout the front yard setback area. No plantings shall obscure site at entrance and exit drives and road intersections. All landscaped areas shall be continuously maintained, substantially in accordance with any site plan approved pursuant to Article IX herein
|
Minimum Yard Setbacks
(feet)
| ||||||||
---|---|---|---|---|---|---|---|---|
Zoning District
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
|
Side
|
Rear
|
Maximum Building Height
(feet)
|
Maximum Lot Coverage as % of
Lot Area
|
MB-A1
MB-A2
|
10,000
|
20
|
—
|
—
|
—
|
—
|
301
|
—
|
MB-B
|
7,500
|
20
|
75
|
10
|
302
|
30
|
301
|
—
|
1
|
Or two stories, whichever is lesser
| |||||||||
2
|
The minimum total side yard setback
shall be 30 feet, provided that no allocation of such total results
in a setback of less than 10 feet, except abutting a residential district,
where a minimum of 20 feet is required.
| |||||||||
NOTE:
| ||||||||||
A.
|
Front yard landscaped setback from
the road lot line:
| |||||||||
MB-A1 and MB-A2 Business District:
10 feet.
| ||||||||||
MB-B Business District: 10 feet.
| ||||||||||
B.
|
Side/rear yard landscaped setback from
residential lot lines:
| |||||||||
MB-A1 Business District: 50 feet.
| ||||||||||
C.
|
Existing trees and shrubs shall be retained within the road right-of-way and within the required landscaped setbacks and supplemented with other landscape materials, in accordance with accepted landscape practices. Where natural vegetation cannot be retained, the landscaped setback shall be landscaped with a combination of grasses, trees and shrubs commonly found on Cape Cod. A minimum of one street tree with a minimum caliper of three inches shall be provided per 30 feet of road frontage distributed throughout the front yard setback area. No plantings shall obscure site at entrance and exit drives and road intersections. All landscape areas shall be continuously maintained, substantially in accordance with any site plan approved pursuant to Article IX herein.
|
Minimum Yard Setbacks
| ||||||||
---|---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
(feet)
|
Side
(feet)
|
Rear
(feet)
|
Maximum Building Height
(feet)
|
Maximum Lot Coverage as % of
Lot Area
|
VB-A
|
10,000
|
20
|
100
|
10
|
302
|
20
|
301
|
25
|
NOTES:
| |||||||||
---|---|---|---|---|---|---|---|---|---|
1
|
Or two stories, whichever is lesser
| ||||||||
2
|
The minimum total side yard setback
shall be 30 feet, provided that no allocation of such total results
in a setback of less than the 10 feet, except abutting a residential
district, where a minimum of 20 feet is required.
| ||||||||
3
|
No more than 33% of the total upland
area of any lot shall be made impervious by the installation of buildings,
structures and paved surfaces.
| ||||||||
Front yard landscaped setback from
the road lot line:
VB-A 10 feet.
Existing trees and shrubs shall be retained within the road right-of-way and within the required front yard landscaped setback and supplemented with other landscape materials, in accordance with accepted landscape practices. Where natural vegetation cannot be retained, the front yard landscaped setback shall be landscaped with a combination of grasses, trees and shrubs commonly found on Cape Cod. A minimum of one street tree with a minimum caliper of three inches shall be provided per 30 feet of road frontage distributed throughout the front yard setback area. No plantings shall obscure site at entrance and exit drives and road intersections. All landscaped areas shall be continuously maintained, substantially in accordance with any site plan approved pursuant to Article IX herein.
|
Table 1.
| |||||||
---|---|---|---|---|---|---|---|
Use Category Specific Use
|
DMS
|
DV
|
DN
|
DH
|
HH
|
TC
|
HC
|
Commercial services (except as follows)
|
P
|
P
|
N
|
P
|
P
|
P
|
P
|
Automobile maintenance and repair
|
N
|
N
|
N
|
N
|
N
|
N
|
N
|
Boat storage and repair
|
N
|
N
|
N
|
N
|
P
|
N
|
N
|
Contractor services
|
N
|
N
|
N
|
N
|
N
|
N
|
N
|
Funeral services
|
N
|
N
|
N
|
N
|
N
|
N
|
N
|
Marina
|
N
|
N
|
N
|
N
|
P
|
N
|
N
|
Commercial parking
|
N
|
N
|
N
|
N
|
N
|
P
|
SP
|
Public transportation maintenance
|
N
|
N
|
N
|
N
|
N
|
SP
|
N
|
Recreational facility
|
SP
|
SP
|
N
|
SP
|
SP
|
SP
|
SP
|
Self-storage facility
|
N
|
N
|
N
|
N
|
N
|
N
|
SP
|
Veterinary services
|
SP
|
SP
|
N
|
N
|
N
|
N
|
P
|
Cultural services (as specified below)
|
—
|
—
|
—
|
—
|
—
|
—
|
—
|
Arts and culture establishments
|
P
|
P
|
N
|
N
|
P
|
P
|
P
|
Fraternal and social organizations
|
P
|
P
|
N
|
N
|
P
|
P
|
P
|
Performing arts and theaters
|
P
|
P
|
N
|
N
|
P
|
P
|
P
|
Artist live/work
|
P
|
P
|
P
|
N
|
P
|
P
|
N
|
Food and beverage services (except as follows)
|
L
|
L
|
N
|
SP
|
L
|
L
|
SP
|
Brewery/distillery
|
L
|
N
|
N
|
N
|
N
|
N
|
N
|
Hospital
|
N
|
N
|
N
|
P
|
N
|
N
|
N
|
Office (except as follows)
|
P
|
P
|
L
|
P
|
P
|
P
|
P
|
Health care clinic
|
P
|
P
|
L
|
P
|
P
|
N
|
P
|
Research and development
|
P
|
P
|
N
|
P
|
P
|
N
|
P
|
Residential (as specified below)
|
—
|
—
|
—
|
—
|
—
|
—
|
—
|
Multiunit dwelling
|
L
|
L
|
L
|
N
|
L
|
L
|
N
|
Two-unit dwelling
|
P
|
P
|
L
|
N
|
N
|
N
|
N
|
Single unit dwelling
|
N
|
P
|
P
|
N
|
N
|
N
|
N
|
Retail sales (except as follows)
|
L
|
L
|
N
|
SP
|
L
|
L
|
SP
|
Boat sales
|
N
|
N
|
N
|
N
|
SP
|
N
|
N
|
Gasoline sales
|
N
|
N
|
N
|
N
|
N
|
N
|
N
|
Motor vehicle sales
|
N
|
N
|
N
|
N
|
N
|
N
|
N
|
Visitor accommodations (as specified below)
|
—
|
—
|
—
|
—
|
—
|
—
|
—
|
Hotel/motel
|
P
|
N
|
N
|
N
|
P
|
N
|
P
|
Bed-and-breakfast
|
N
|
P
|
P
|
N
|
P
|
N
|
N
|
P Permitted by right
|
SP Special permit
|
N Not permitted
|
L Permitted with limitations (see district)
|
Table 2.
Minimum Required Accessory Parking Spaces
| ||||||||
---|---|---|---|---|---|---|---|---|
Use Category
|
DMS
|
DV
|
DN
|
DH
|
HH
|
TC
|
HC
|
On Site Shared Parking Adjustment1
|
Commercial services (per 1,000 square feet)
|
0
|
4
|
N/A
|
4
|
4
|
4
|
4
|
Reduce by 50% the required spaces for commercial services where
mixed with residential uses on the same lot
|
Cultural services (per 1,000 square feet)
|
0
|
4
|
4
|
4
|
N/A
|
4
|
4
|
Reduce by 20% the required spaces for cultural services where
mixed with residential uses on the same lot
|
Food and beverage services (per 1,000 square feet)
|
0
|
4
|
N/A
|
4
|
4
|
4
|
4
|
—
|
Hospital (per 3 beds)
|
N/A
|
N/A
|
N/A
|
1
|
N/A
|
N/A
|
N/A
|
—
|
Office (per 1,000 square feet)
|
3
|
3
|
3
|
3
|
3
|
3
|
3
|
Reduce by 50% the required spaces for office where mixed with
residential uses on the same lot
|
Residential or artist live/work (per DU)
|
1
|
1
|
1
|
N/A
|
1
|
1
|
N/A
|
—
|
Retail sales (per 1,000 square feet)
|
0
|
4
|
N/A
|
4
|
4
|
4
|
4
|
Reduce by 20% the required spaces for retail sales where mixed
with residential uses on the same lot
|
Visitor accommodations (per room)
|
1.25
|
1.25
|
1.25
|
N/A
|
1.25
|
N/A
|
1.25
|
—
|
Table 3. DMS Dimensional Standards
| |||
---|---|---|---|
Lot
|
Building Form
| ||
Lot width
|
30 feet minimum
|
E - Building width
|
180 feet maximum
|
Lot coverage
|
100% maximum
|
F - Number of stories
|
3.5 or 4 maximum1
|
Facade buildout (minimum)
|
—
|
G - Ground story height
|
—
|
Primary frontage
|
80% minimum
|
Commercial
|
14 feet minimum
|
Secondary frontage
|
40% minimum
|
Residential
|
10 feet minimum
|
Setbacks - Principal Buildings
|
H - Upper story height
|
10 feet minimum
| |
A - Primary front setback
|
0 foot minimum 15 feet maximum
|
Building Features
| |
B - Secondary front setback
|
0 foot minimum 15 feet maximum
|
Ground story fenestration
|
—
|
C - Side setback
|
0 foot minimum
|
Primary frontage
|
60% minimum
|
D - Rear setback
|
0 foot minimum
|
Secondary frontage
|
15% minimum
|
Upper story fenestration
|
15% minimum
| ||
Blank wall
|
20 feet maximum
| ||
Commercial space depth
|
20 feet minimum
|
1
|
See § 240-24.1.6C6 (fourth story step-back).
|
Table 4. DV Dimensional Standards
| |||
---|---|---|---|
Lot
|
Building Form
| ||
Lot width
|
30 feet minimum
|
E - Building width
|
120 feet maximum
|
Lot coverage
|
80% maximum
|
F - Number of stories
|
3.5 or 4 maximum1
|
Facade buildout (minimum)
|
—
|
G - Ground story height
|
—
|
Primary frontage
|
80% minimum
|
Commercial
|
14 feet minimum
|
Residential
|
10 feet minimum
| ||
Setbacks - Principal Buildings
|
Upper story height
|
10 feet minimum
| |
A - Primary front setback
|
0 foot minimum
15 feet maximum
|
Building Features
| |
B - Secondary front setback
|
0 foot minimum
15 feet maximum
|
Ground story fenestration
|
—
|
C - Side setback
|
0 foot minimum
|
Primary frontage
|
15% minimum
|
D - Rear setback
|
0 foot minimum
|
Secondary frontage
|
15% minimum
|
Upper story fenestration
|
15% minimum
| ||
Blank wall
|
20 feet maximum
| ||
Commercial space depth
|
20 feet minimum
|
1
|
See § 240-24.1.7C4 (fourth story step-back).
|
Table 5. DN Dimensional Standards
| |||
---|---|---|---|
Lot
|
Building Form
| ||
Lot width
|
20 feet minimum
|
E - Number of stories
|
3 maximum1
|
Lot coverage
|
50% maximum
|
F - Ground story height
|
10 feet minimum
|
Setbacks - Principal Buildings
|
G - Upper story height
|
10 feet minimum
| |
A - Primary front setback
|
10 feet minimum
20 feet maximum
| ||
B - Secondary front setback
|
10 feet minimum
20 feet maximum
| ||
C - Side setback
|
10 feet minimum
| ||
D - Rear setback
|
20 feet minimum
| ||
Setbacks - Outbuildings
| |||
Front setback
|
60 feet minimum
| ||
Side setback
|
3 feet minimum
| ||
Rear setback
|
3 feet minimum
|
1
|
See § 240-24.1.8C2(a)
|
Table 6. DH Dimensional Standards
| |||
---|---|---|---|
Lot
|
Building Form
| ||
Lot width
|
50 feet minimum
|
Number of stories
|
6 maximum
|
Lot coverage
|
100% maximum
|
Building height
|
85 feet maximum
|
Setbacks - Principal Buildings
| |||
Primary front setback
|
20 feet minimum
| ||
Secondary front setback
|
20 feet minimum
| ||
Side setback
|
10 feet minimum
| ||
Rear setback
|
10 feet minimum
|
Table 7. HH Dimensional Standards
| |||
---|---|---|---|
Lot
|
Building Form
| ||
Lot width
|
20 feet minimum
|
Number of stories
|
2.5 maximum
|
Lot coverage
|
90% maximum
|
Building height
|
35 feet maximum1
|
Setbacks - principal buildings
| |||
Primary front setback
|
20 feet minimum
| ||
Secondary front setback
|
20 feet minimum
| ||
Side setback
|
10 feet minimum
| ||
Rear setback
|
10 feet minimum
|
1
|
See § 240-24.1.10C2(a).
|
Table 8. TC Dimensional Standards.
| |||
---|---|---|---|
Lot
|
Building Form
| ||
Lot width
|
50 feet minimum
|
Number of stories
|
3 maximum
|
Lot coverage
|
65% maximum
|
Building height
|
40 feet maximum
|
Setbacks - Principal Buildings
| |||
Primary front setback
|
—
| ||
Lots fronting Route 28
|
50 feet minimum
| ||
All other lots
|
20 feet minimum
| ||
Secondary front setback
|
20 feet minimum
| ||
Side setback
|
10 feet minimum
| ||
Rear setback
|
10 feet minimum
|
Table 9. HC Dimensional Standards
| |||
---|---|---|---|
Lot
|
Building Form
| ||
Lot width
|
50 feet minimum
|
Number of stories (maximum)
|
31
|
Lot coverage
|
80% maximum
|
Building height
|
40 feet maximum
|
Setbacks - Principal Buildings
| |||
Primary front setback
|
60 feet maximum
| ||
Lots fronting Route 28
|
20 feet minimum
| ||
Secondary front setback
|
20 feet minimum
| ||
Side setback
|
10 feet minimum
| ||
Rear setback
|
10 feet minimum
|
1
|
See § 240-24.1.12C2(a).
|
Table 10. Dimensional Standards Summary Table
| |||||||
---|---|---|---|---|---|---|---|
DMS
|
DV
|
DN
|
DH
|
HH
|
TC
|
HC
| |
A. Lot
| |||||||
Lot width
|
30 feet minimum
|
30 feet minimum
|
20 feet minimum
|
50 feet minimum
|
20 feet minimum
|
50 feet minimum
|
50 feet minimum
|
Lot coverage
|
100% maximum
|
80% maximum
|
50% maximum
|
100% maximum
|
90% maximum
|
65% maximum
|
80% maximum
|
Facade buildout
|
—
|
—
|
—
|
—
|
—
|
—
|
—
|
Primary frontage
|
80% minimum
|
80% minimum
|
—
|
—
|
—
|
—
|
—
|
Secondary frontage
|
40% minimum
|
—
|
—
|
—
|
—
|
—
| |
B. Setbacks - Principal Building
| |||||||
Primary front setback
|
0 foot minimum
15 feet maximum
|
0 foot minimum
15 feet maximum
|
10 feet minimum
20 feet maximum
|
20 feet minimum
|
20 feet minimum
|
20 feet minimum
|
60 feet maximum
|
Lots fronting Route 28
|
—
|
—
|
—
|
—
|
—
|
50 feet minimum
|
20 feet minimum
|
Secondary front setback
|
0 foot minimum
15 feet maximum
|
0 foot minimum
15 feet maximum
|
10 feet minimum
20 feet maximum
|
20 feet minimum
|
20 feet minimum
|
20 feet minimum
|
20 feet minimum
|
Side setback
|
0 foot minimum
|
0 foot minimum
|
10 feet minimum
|
10 feet minimum
|
10 feet minimum
|
10 feet minimum
|
10 feet minimum
|
Rear setback
|
0 foot minimum
|
0 foot minimum
|
20 feet minimum
|
10 feet minimum
|
10 feet minimum
|
10 feet minimum
|
10 feet minimum
|
C. Setbacks - Outbuilding
| |||||||
Primary front setback
|
—
|
—
|
60 feet minimum
|
—
|
—
|
—
|
—
|
Secondary front setback
|
—
|
—
|
—
|
—
|
—
|
—
|
—
|
Side setback
|
—
|
—
|
3 feet minimum
|
—
|
—
|
—
|
—
|
Rear setback
|
—
|
—
|
3 feet minimum
|
—
|
—
|
—
|
—
|
D. Building Form
| |||||||
Building width
|
180 feet maximum
|
120 feet maximum
|
—
|
—
|
—
|
—
|
—
|
Number of stories
|
—
|
—
|
—
|
—
|
—
|
—
|
—
|
Principal building
|
3.5 or
4 maximum1
|
3.5 or
4 maximum2
|
3 maximum3
|
6 maximum
|
2.5 maximum
|
3 maximum
|
3 maximum4
|
Outbuilding
|
—
|
—
|
—
|
—
|
—
|
—
|
—
|
Ground story height
|
—
|
—
|
10 feet minimum
|
—
|
—
|
—
|
—
|
Commercial
|
14 feet minimum
|
14 feet minimum
|
—
|
—
|
—
|
—
|
—
|
Residential
|
10 feet minimum
|
10 feet minimum
|
—
|
—
|
—
|
—
|
—
|
Upper story height
|
10 feet minimum
|
10 feet minimum
|
10 feet minimum
|
—
|
—
|
—
|
—
|
Building height
|
—
|
—
|
—
|
85 feet maximum
|
35 feet maximum5
|
40 feet maximum
|
40 feet maximum
|
E. Building Features
| |||||||
Ground story fenestration
|
—
|
—
|
—
|
—
|
—
|
—
|
—
|
Primary frontage
|
60% minimum
|
15% minimum
|
—
|
—
|
—
|
—
|
—
|
Secondary frontage
|
15% minimum
|
15% minimum
|
—
|
—
|
—
|
—
|
—
|
Upper story fenestration
|
15% minimum
|
15% minimum
|
—
|
—
|
—
|
—
|
—
|
Blank wall
|
20 feet maximum
|
20 feet maximum
|
—
|
—
|
—
|
—
|
—
|
Commercial space depth
|
20 feet minimum
|
20 feet minimum
|
1
|
See § 240-24.1.6C6 (fourth Story Step-back).
|
2
|
See § 240-24.1.7C4 (fourth Story Step-back).
|
3
|
See § 240-24.18C2(a).
|
4
|
See § 240-24.1.12C2(a).
|
5
|
See § 240-24.1.10C2(a).
|
Table 11. Frontage Types
| ||||||||
---|---|---|---|---|---|---|---|---|
P - Permitted
|
N - Not Permitted
|
DMS
|
DV
|
DN
|
DH
|
HH
|
TC
|
HC
|
Gallery
A frontage type consisting of a storefront(s) and an attached
colonnade with a roof, open pergola, or balcony overhanging a paved
sidewalk. A gallery may wrap around the corner of a building to create
a veranda-like gallery.
|
P
|
P
|
N
|
N/A
|
P
|
P
|
P
| |
Storefront
A frontage type consisting of an assembly of commercial entry
doors and display windows providing access and light to a commercial
space and a place to display goods, services, and signs.
|
P
|
P
|
N
|
N/A
|
P
|
P
|
P
| |
Common Lobby
A frontage type consisting of an assembly of entry doors and
windows providing access and light to the lobby of a building. A common
lobby may be combined with an entry plaza or front garden frontage
type.
|
P
|
P
|
N
|
N/A
|
P
|
P
|
P
| |
Dining Patio
A frontage type consisting of a storefront(s) and outdoor cafe
seating in the frontage area.
|
P
|
P
|
N
|
N/A
|
P
|
P
|
P
| |
Entry Plaza
A frontage type consisting of a storefront(s) and a highly paved
frontage area. An entry plaza may be combined with a common lobby
frontage type.
|
P
|
P
|
N
|
N/A
|
P
|
P
|
P
| |
Front Garden
A frontage type consisting of a highly landscaped frontage area.
A front garden may be combined with a common lobby, dooryard or stoop,
or porch frontage type.
|
N
|
P
|
P
|
N/A
|
N
|
N
|
N
| |
Dooryard or Stoop
A frontage type consisting of a zero-step entrance or a set
of stairs with a landing that provides access to the entrance of a
building. A dooryard or stoop may be combined with a front garden
frontage type.
|
N
|
P
|
P
|
N/A
|
N
|
N
|
N
| |
Porch
A frontage type consisting of a raised platform with a roof
supported by columns, piers, or posts; an area for seating; and an
optional set of stairs with a landing that provides access to the
entrance of a building. A porch may be combined with a front garden
frontage type.
|
N
|
P
|
P
|
N/A
|
N
|
N
|
N
|
Table 12. Building Components
| |||||
---|---|---|---|---|---|
A. Balcony
|
B. Bay or Oriel Window
| ||||
A
|
Width (minimum)
|
5 feet
|
A
|
Single bay width (maximum)
|
16 feet
|
B
|
Depth (minimum)
|
4 feet
|
Cumulative bay width (maximum)
|
50% of the width of the exterior wall from which the bays project
| |
Area (minimum)
|
20 square feet
|
B
|
Projection (maximum)
|
3 feet
| |
C
|
Front setback encroachment (maximum)
|
5 feet
|
C
|
Stories (maximum)
|
Same as the principal building
|
D
|
Front setback encroachment (maximum)
|
3 feet
| |||
Design standards:
Balconies may attach to any exterior wall of a principal building.
Balconies may be recessed, projecting, a combination of the
two, or terraced as part of the roof of a permitted building component.
|
Design standards:
Bays may attach to any exterior wall of a principal building.
A bay window may have a flat roof.
| ||||
C.
|
Dormer
|
D.
|
Cross Gable
| ||
A
|
Cumulative width of all dormers (maximum)
|
50% of the roof eave
|
A
|
Width (maximum)
|
50% of the roof eave below
|
B
|
Exterior wall setback (minimum)
|
—
|
B
|
Height (minimum)
|
Equal to the height of the roof of the attached primary massing
|
Roof with eave
|
0 feet
|
Design standards:
The roof ridge of a cross gable must be perpendicular to the
main roof ridge of the principal building.
The rakes and ridge of the roof of the cross gable must be structurally
integrated into the eave and ridge of roof of the attached primary
massing.
| |||
Roof without eave
|
1 feet
| ||||
C
|
Setback from gable (minimum)
|
3 feet
| |||
D
|
Separation from another dormer (minimum)
|
50% of dormer width
| |||
Design standards:
The face wall of a dormer window may not project beyond the
exterior wall of the building and may not interrupt the eave of the
roof.
|
E.
|
Projecting Gable
| |
A
|
Width (maximum)
|
Equal to the shortest side of the attached primary massing
|
B
|
Projection (maximum)
|
6 feet
|
C
|
Height (minimum)
|
Height of building in stories
|
D
|
Front setback encroachment (maximum)
|
6 feet
|
Design standards:
A projecting gable may attach only the facade of a principal
building.
The roof ridge of a projecting gable must be perpendicular to
the main roof ridge of the principal building.
|
Minimum Yard Setbacks
| ||||||
---|---|---|---|---|---|---|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Front4
(feet)
|
Side
(feet)1
|
Rear
(feet)1
|
Maximum Building Height
(feet)
|
Maximum Coverage by Structures as a Percentage of Lot
Area3
|
10,000
|
20
|
10
|
0
|
0
|
302
|
20%
|
Notes:
| ||
---|---|---|
1 A minimum thirty-foot side or rear
yard setback is required where lot boundaries abut a residential district.
| ||
2 Or 2 1/2 stories, whichever is
less, and except that:
| ||
The maximum building height may be increased to 36 feet when
the roof pitch is at least six in 12.
| ||
Accessory rooftop equipment may extend to 36 feet, provided
that it is set back from all exterior wall(s) by at least 10 feet,
and is enclosed or screened with materials compatible with the building,
and the equipment and screening are not visible from the ground. Accessory
equipment shall not exceed 20% of the roof area.
| ||
3 30% of the total upland area of the lot shall remain pervious and may contain landscaping, tree plantings, mulch or natural vegetation including the requirements of § 240-53.
| ||
4 Front yard landscape setback from the road lot line shall be 10 feet. Existing trees and shrubs shall be retained within the road right-of-way and within the required front yard landscaped setback and supplemented with other landscape materials, in accordance with accepted landscape practices. Where natural vegetation cannot be retained, the front yard landscaped setback shall be landscaped with a combination of grasses, trees and shrubs commonly found on Cape Cod. A minimum of one street tree with a minimum caliper of 3.0 inches shall be provided per 30 feet of road frontage distributed throughout the front yard setback area. No plantings shall obscure the site at entrance and exit drives and road intersections. All landscaped areas shall be continuously maintained, substantially in accordance with any site plan approved pursuant to Article IX herein.
|
1 Drive-throughs shall be permitted accessory to such use, subject to the issuance of a Special Permit pursuant to § 240-25C herein.
|
2 The landscape setback from all
residential property lines shall be 20 feet. Within the landscape
buffer, existing mature trees shall be retained and shall be supplemented
with plantings that will provide dense year-round screening, or a
solid fence with landscape plantings on the residential side.
|
3 Parking areas for commercial vehicles
and any exterior areas used for loading or storage and dumpsters shall
be screened from view from the public way.
|
1 The landscape setback from all
residential property lines shall be 10 feet. Within the landscape
buffer, existing mature trees shall be retained and shall be supplemented
with plantings that will provide dense year-round screening, or a
solid fence with landscape plantings on the residential side.
|
2 Parking areas for commercial vehicles
and any exterior areas used for loading or storage and dumpsters shall
be screened from view from the public way.
|
Minimum Yard Setbacks (Feet)
| ||||||||
---|---|---|---|---|---|---|---|---|
Zoning District
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
|
Rear
|
Side
|
Maximum Building Height
(feet)
|
Maximum Lot Coverage as % of Lot Area
|
HB
|
15,000
|
20
|
100
|
201, 2
|
20
|
10
|
383
|
30
|
1 Forty feet along Route 28 and Route
132.
|
2 The front yard setback shall be a landscape setback in which existing trees and shrubs shall be retained within and supplemented with other landscape materials in accordance with accepted landscape practices. Where natural vegetation cannot be retained, the front yard landscape setback shall be landscaped with a combination of grasses, trees and shrubs commonly found on Cape Cod. A minimum of one street tree with a minimum caliper of three inches shall be provided per 30 feet of road frontage and distributed throughout the front yard landscape setback area. No plantings shall obscure site entrance and exit drives and/or road intersections. All landscape areas shall be continuously maintained substantially in accordance with Article IX herein.
|
3 Or three stories, whichever is
lesser.
|
Minimum Yard Setbacks
(feet)
| ||||||||
---|---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
|
Side
|
Rear
|
Maximum Building Height
(feet)
|
Maximum Floor Area Ratio 2
|
HO
|
2 acres
|
200
|
—
|
45
|
15
|
20
|
301
|
0.3
|
1
|
Or two stories, whichever is lesser.
| ||||||||
3
|
Floor area ratio (FAR) is the ratio
of gross building square feet to lot area.
| ||||||||
NOTE: Front yard landscaped setback from the road lot line: 45 feet. Existing trees and shrubs shall be retained within the road right-of-way and within the required front yard landscaped setback. Where natural vegetation cannot be retained, the front yard landscaped setback shall be landscaped with a combination of grasses, trees and shrubs commonly found on Cape Cod. A minimum of one street tree with a minimum caliper of three inches shall be provided per 30 feet of road frontage distributed throughout the front yard setback area. No plantings shall obscure site at entrance and exit drives and road intersections. All landscaped areas shall be continuously maintained, substantially in accordance with any site plan approved pursuant to Article IX herein.
|
Minimum Yard Setbacks (feet)
| ||||||||
---|---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
|
Side
|
Rear
|
Maximum Building Height
(feet)
|
Maximum Lot Coverage as % of
Lot Area
|
S&D
|
43,560
|
20
|
160
|
60
|
25
|
40
|
301
|
25
|
1
|
Or two stories, whichever is lesser.
| ||||||||
NOTE: Front yard landscaped setback
from the road lot line:
S &D: 20 feet, 60 feet from Route
28.
Existing trees and shrubs shall be retained within the road right-of-way and within the required front yard landscaped setback and supplemented with other landscape materials, in accordance with accepted landscape practices. Where natural vegetation cannot be retained, the front yard landscaped setback shall be landscaped with a combination of grasses, trees and shrubs commonly found on Cape Cod. A minimum of one street tree with a minimum caliper of three inches shall be provided per 30 feet of road frontage distributed throughout the front yard setback area. No plantings shall obscure site at entrance and exit drives and road intersections. All landscaped areas shall be continuously maintained, substantially in accordance with any site plan approved pursuant to Article IX herein.
[Amended 3-11-1999 by Order No.
99-056] |
Minimum Yard Setbacks
| ||||||||
---|---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
(feet)
|
Side
(feet)
|
Rear
(feet)
|
Maximum Building Height
(feet)
|
Maximum Floor Area Ratio 2
Retail/All Other
|
SD-1
|
43,560
|
150
|
—
|
45
|
15
|
20
|
301
|
0.25/0.30
|
NOTES:
| |||||||||
1
|
Or two stories, whichever is lesser.
| ||||||||
2
|
Floor area ratio (FAR) is the ratio
of gross building square feet to lot area.
| ||||||||
Front yard landscaped setback from
the road right-of-way: 20 feet, 45 feet from Route 28.
Existing trees and shrubs shall be retained within the road right-of-way and within the required front yard landscaped setback and supplemented with other landscape materials, in accordance with accepted landscape practices. Where natural vegetation cannot be retained, the front yard landscaped setback shall be landscaped with a combination of grasses, trees and shrubs commonly found on Cape Cod. A minimum of one street tree with a minimum caliper of three inches shall be provided per 30 feet of road frontage distributed throughout the front yard setback area. No plantings shall obscure site at entrance and exit drives and road intersections. All landscaped areas shall be continuously maintained, substantially in accordance with any site plan approved pursuant to Article IX herein.
[Added 7-15-1999] |
SCCRCOD Uses
|
Minimum Number of Spaces
|
Guest Spaces
| |
---|---|---|---|
Independent-living dwelling unit
|
0.75 per dwelling unit
|
0.5 per dwelling unit
| |
Assisted-living dwelling unit
|
0.5 per dwelling unit
|
0.5 per dwelling unit
| |
Skilled care facility
|
0.5 per bed
|
0.5 per bed
| |
Employee — dwelling unit administration
|
0.75 per 5 dwelling units
|
N/A
| |
Employee — skilled care facility
|
0.5 per bed
|
N/A
|
Minimum Yard Setbacks
| ||||||||
---|---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
(feet)
|
Side
(feet)
|
Rear
(feet)
|
Maximum Building Height
(feet)
|
Maximum Lot Coverage as % of
Lot Area
|
IND LTD
|
90,000
|
20
|
200
|
50
|
30
|
30
|
301
|
25
|
NOTES:
| |||||||||
1
|
Or two stories, whichever is lesser.
|
Minimum Yard Setbacks
(feet)
| ||||||||
---|---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front1
|
Side2
|
Rear2
|
Maximum Building Height
(feet)
|
Maximum Lot Coverage as % of Lot Area4
|
IND
|
90,000
|
20
|
200
|
60
|
30
|
30
|
303
|
25
|
1
|
For sports and recreation facilities, outdoor uses (e.g., fields,
tracks, courts and swimming pools, etc.) and their accessory structures
with a footprint of less than 2,000 square feet shall have a minimum
front yard setback of 20 feet; provided however, that for such outdoor
uses which are temporarily (i.e., not more than 182 days) covered
by an air-supported or removable bubble/dome, said temporary bubble/dome
shall have a minimum front yard setback of 15 feet. Retaining walls
(including those used for outdoor climbing) and outdoor field/court
lighting for sports and recreation facilities shall not be subject
to these setbacks.
| ||||||||
2
|
For sports and recreation facilities, outdoor uses (e.g., fields,
tracks, courts and swimming pools, etc.) and their accessory structures
with a footprint of less than 2,000 square feet shall have a minimum
side and rear setback of 10 feet; this ten-foot side/rear setback
shall also apply to such outdoor uses which are temporarily (i.e.,
not more than 182 days) covered by an air-supported or removable bubble/dome.
Retaining walls (including those used for outdoor climbing) and outdoor
field/court lighting for sports and recreation facilities shall not
be subject to these setbacks.
| ||||||||
3
|
Or two stories, whichever is lesser; except that for sports
and recreation facilities, the maximum building height shall be 55
feet measured to the highest point on the roof (not including antennas
or similar roof fixtures).
| ||||||||
4
|
For sports and recreation facilities, the following outdoor
uses shall not be considered structures included in this calculation:
open-air solar-mounted carports, fields (grass or turf), courts, tracks,
swimming pools, retaining walls, and similar outdoor, open-air features;
additionally, any such outdoor uses which are temporarily (i.e., not
more than 182 days) covered by an air-supported or removable bubble/dome
shall not be included in this calculation.
|
FEMA Region I Risk Analysis Branch Chief
99 High St., 6th floor, Boston, MA 02110
|
|
And copy of notification to:
|
Massachusetts NFIP State Coordinator
MA Dept. of Conservation & Recreation, 251 Causeway Street,
Boston, MA 02114
|
[U.S. Code of Federal Regulations, Title 44, Part 59]
|
AP
|
Aquifer Protection Overlay District
| |
GP
|
Groundwater Protection Overlay District
| |
WP
|
Well Protection Overlay District
|
and provided that such storage is either in
a freestanding container within a building or in a freestanding container
above ground level with protection adequate to contain a spill the
size of the container's total storage capacity; however, replacement
of existing tanks or systems for the keeping, dispensing or storing
of gasoline is allowed consistent with state and local requirements;
and
|
Minimum Yard Setbacks
(feet)
| ||||||||
---|---|---|---|---|---|---|---|---|
Zoning Districts
|
Minimum Lot Area
(square feet)
|
Minimum Lot Frontage
(feet)
|
Minimum Lot Width
(feet)
|
Front
|
Side
|
Rear
|
Maximum Building Height
(feet)
|
Maximum Lot Coverage as % of
Lot Area
|
FG-5 PUD
|
43,560
|
20
|
--
|
50
|
50
|
50
|
38
|
501
|
Notes:
| |
1
|