TABLE I
Maximum Permissible A-Weighted Sound Levels
| ||||
---|---|---|---|---|
1.
|
No person shall cause, suffer, allow, or permit the operation of any source of sound on any source property listed in § 135-2A above in such a manner as to create a sound level that equals or exceeds the sound levels listed below:
| |||
A.
|
Outdoors
|
Receiving Property Category
|
Residential property, or residential portion of a multiuse property
|
Commercial facility, public service facility nonresidential portion
of a multiuse property, or community service facility
| |
---|---|---|---|
Time
|
7:00 a.m. - 10:00 p.m.
|
10:00 p.m. - 7:00 a.m.
|
24 hours
|
Maximum
| |||
A-weighted sound level standard (dB)
|
65
|
50
|
65
|
B.
|
Indoors
|
Receiving Property Category
|
Residential property, or residential portion of a multiuse property
|
Commercial facility*, or nonresidential portion of a multiuse
property
| |
---|---|---|---|
Time
|
7:00 a.m. - 10:00 p.m.
|
10:00 p.m. - 7:00 a.m.
|
24 hours
|
Maximum
| |||
A-weighted sound level standard (dB)
|
55
|
40
|
55
|
*In those instances when a commercial facility shares a common wall/ceiling/floor
with another commercial facility that is producing the sound.
|
TABLE II
Maximum Permissible Octave Band Sound Pressure Levels In Decibels
| ||
---|---|---|
1.
|
No person shall cause, suffer, allow, or permit the operation of any source of sound on any source property listed in § 135-2A above in such a manner as to create a sound pressure level that equals or exceeds the sound levels listed below in one or more octave band.
[Amended 6-18-2003 by Ord. No. 886-03] | |
2.
|
When octave measurements are made, the sound from the source must be
constant in level and character. If octave band sound pressure level variations
exceed plus or minus 2dB in the bands containing the principal source frequencies,
discontinue the measurement.
|
Receiving Property Category
|
Residential property, or residential portion of a multiuse
property
|
Residential property, or residential portion of a multiuse
property
|
Commercial facility, public service facility, nonresidential
portion of a multiuse property,
|
Commercial facility* or nonresidential portion of a multiuse
property
| ||
---|---|---|---|---|---|---|
Outdoors
|
Indoors
|
Outdoors
|
Indoors
| |||
Octave Band Center Frequency
(Hz)
|
Octave Band Sound Pressure Level
(dB)
|
Octave Band Sound Pressure Level
(dB)
|
Octave Band Sound Pressure Level
(dB)
|
Octave Band Sound Pressure Level
(dB)
| ||
Time
|
7:00 a.m. - 10:00 p.m.
|
10:00 p.m. - 7:00 a.m.
|
7:00 a.m. - 10:00 p.m.
|
10:00 p.m. - 7:00 a.m.
|
24 hours
|
24 hours
|
31.5
|
96
|
86
|
86
|
76
|
96
|
86
|
63
|
82
|
71
|
72
|
61
|
82
|
72
|
125
|
74
|
61
|
64
|
51
|
74
|
64
|
250
|
67
|
53
|
57
|
43
|
67
|
57
|
500
|
63
|
48
|
53
|
38
|
63
|
53
|
1,000
|
60
|
45
|
50
|
35
|
60
|
50
|
2,000
|
57
|
42
|
47
|
32
|
57
|
47
|
4,000
|
55
|
40
|
45
|
30
|
55
|
45
|
8,000
|
53
|
38
|
43
|
28
|
53
|
43
|
*In those instances when a commercial facility shares a common wall/ceiling/floor