Area and Dimensional Requirements: O-R | Requirements for Tract1 | Requirements for Each Lot Within the Tract2 |
---|---|---|
Minimum net lot area | 25 acres | 2 acres |
Minimum average net lot areas | 3 acres | |
Minimum width | 200 feet or 40% of the maximum tract depth, whichever is greater | 200 feet |
Maximum building coverage | 35% | Must be limited so that tract requirement of 35% is not exceeded |
Maximum impervious surface ratio | 65% | Must be limited so that tract requirement of 65% is not exceeded |
Front yard | 100 feet | 50 feet |
Side yard | 75 feet/100 feet if adjoining a residential district | 50 feet |
Rear yard | 75 feet/100 feet if adjoining a residential district | 50 feet |
Maximum building height | 3 stories, up to a maximum of 50 feet not including mechanical equipment located on the roof3 | 3 stories, up to a maximum of 50 feet not including mechanical equipment located on the roof3 |
Maximum building height | 35 feet | 35 feet |
NOTES: 1 Tract requirements shall apply to any property held in single and separate ownership on the date of adoption of this amendment. (Editor's Note: The date of adoption of this amendment is 4-6-1998.) |
2 The lot requirements shall apply to lots created by subdivision after the effective date of this amendment, shall only apply to boundary lines newly created by such subdivisions and shall not apply to boundary lines existing on the effective date of the adoption of this amendment. In cases of subdivisions without land development, the applicable setbacks shall be recorded on the linen. (Editor's Note: The effective date of this amendment is 4-11-1998.) 3 Mechanical equipment located on the roof shall not exceed 10 feet in height, shall be located at least 10 feet from the edges of the building and shall be surrounded by screening constructed in the same general material and appearance as the building, unless otherwise approved by the Board of Supervisors. |