"101.1 Title: These regulations
shall be known as the Plumbing Code of the Borough of Trappe, hereinafter
referred to as "the code" or "this code."
|
"101.4 Severability: If any section,
paragraph, sentence, clause or word of this code or of the ordinance
adopting this code is declared to be unconstitutional, illegal or
invalid, that decision shall not affect the validity of any of the
remaining provisions of the code or of the ordinance adopting the
code. It is declared as a legislative intent that the said code and
ordinance would have been adopted had such unconstitutional, illegal
or invalid provision not been included therein."
|
"102.10 Validity of other laws, regulations
and ordinances: Nothing in this code shall be construed to
prevent the enforcement of other laws, state regulations and ordinances
of this Borough which prescribe more restrictive or stricter requirements
or limitations on any subject covered in this code. When any provision
specified in the code pertaining to health, safety and/or welfare
is more restrictive than any such other provisions, this code shall
control, but in any case, the most rigid requirements of either this
code or other laws, regulations or ordinances shall apply wherever
they may be in conflict."
|
"103.2 Appointment of Plumbing Official;
qualifications and tenure: The Plumbing Official shall be appointed
by Borough Council and shall serve at the pleasure of Council. The
requirements for eligibility for appointment as Plumbing Official
shall be determined by Borough Council through oral and/or written
examinations, interviews or such other means as deemed appropriate
by Council. As determined by Council, and from time to time, an individual
appointed to and holding another Borough appointment may be designated
Plumbing Official under this code as well. Furthermore, the Plumbing
Official under this code may be designated by Council, or by a specific
ordinance, to concurrently hold a comparable office or position, often
designated as "Code Official" or "Building Official" under one or
more other codes or ordinances in effect in the Borough. During the
temporary absence or disability of the Plumbing Official, Council
shall designate an acting Plumbing Official."
|
"103.4 Restriction of employees: An official or employee connected with the enforcement of this code
shall not be engaged in, or directly or indirectly connected with,
the furnishing of labor, materials or appliances for the construction,
alteration or maintenance of a structure where work is to be done
under this code, or the preparation of construction documents thereof,
unless that person is the owner of the structure, nor shall that officer
or employee engage in any work that conflicts with official duties
or with the interests of the office of Plumbing Official."
|
"105.1 Modifications: Whenever
there are practical difficulties involved in carrying out any provision
of this code, and upon application in writing by an owner of the property
involved or his representative (which application shall be kept on
file in the office of the Borough Secretary), the Plumbing Official
shall have power to authorize modifications of specific provisions
and requirements of this code. Such modifications may involve alternative
methods or materials or other types of modifications. Such authorization
shall be granted where there are practical difficulties in the way
of carrying out the strict letter of the code, providing that the
spirit of the code is observed, public safety secured and substantial
justice done. The particulars of every such modification, when granted
or allowed, and the decision of the Plumbing Official on the matter
shall be submitted to Council and kept on file with the Borough Secretary,
and a signed copy shall be furnished to the applicant."
|
"106.1 Permit required:
| |||
"1.
|
No plumbing work shall be commenced until a
permit for the work has been issued by the Borough Secretary following
authorization by the Plumbing Official. Provided, however: A permit
is not required for repairs that involve only the working parts of
a faucet or valve, the clearance of stoppages, or the repairing or
replacement of defective faucets or valves, provided that alterations
are not made in existing piping or fixtures.
| ||
"2.
|
Permits are issued only to master or registered
plumbers in all cases except the following:
| ||
"(a)
|
Any permit required by this code may be issued
to any person to do work required or regulated by this code on property
used exclusively for living purposes, including the usual accessory
buildings and quarters in connection with that building, provided
that such person is the bona fide owner of that dwelling, and that
the owner shall personally purchase all material and perform all labor
in connection with work authorized by the permit. Provided, however,
such plumbing work shall be inspected by the Plumbing Official, as
is the case with other permits under this ordinance."
| ||
"(b)
|
Institutions and manufacturing plants that employ
qualified maintenance crews and which designate one individual who
shall be selected to function in lieu of the Master Plumber and shall
be responsible for securing permits, supervising the work, and paying
fees provided in Section 106.5.2."
|
"Application for permit: Application
for a permit shall be made to the Borough Secretary on forms provided
by the Secretary and shall be accompanied by an adequate description
of the proposed plumbing work and its location and the required fee
as prescribed in Section 106.5.2. The application shall be signed
by the owner of the property or an authorized agent and shall indicate
the proposed occupancy of all parts of the building and of that portion
of the site or lot, if any, not covered by the building or structure
and any other information required by the Plumbing Official."
|
"106.4 Action on application:
| ||
"1.
|
The Plumbing Official shall examine or cause
to be examined every application for a permit, and amendments thereto,
and, within 15 days after the filing of the application, shall either
approve or reject the application. If the application or the construction
documents do not conform to the requirements of this code and all
pertinent laws and ordinances, he shall reject that application in
writing, stating the reasons for rejection. If he is satisfied that
the proposed work will conform to the requirements of this code and
all laws and ordinances applicable thereto, he shall issue a permit
as soon as practicable.
| |
"2.
|
If a permit is denied, the applicant may submit
revised construction documents without payment of any additional fee.
| |
"3.
|
If in the course of the work it is found necessary
to make any changes from the application and construction documents
on which a permit has been issued, an amended application and/or construction
documents shall be submitted and a supplemental permit, subject to
the same conditions applicable to the original application for permit,
shall be issued to cover this change.
| |
"4.
|
A plumbing permit shall not be transferable."
|
"106.5.2 Fee schedule: The fees
for all plumbing work, as set from time to time by resolution of Council,
shall be as indicated in the current fee schedule on file in the Borough
offices.[1]
| ||
Note:
|
When more than one building classification is
incorporated within the plumbing permit, the higher permit fee shall
govern.
| |
Failure to obtain the necessary permits will
result in a penalty of not less than $10 and not exceeding $50 for
each day that work continues without a permit."
|
"106.5.3 Fee refunds: The Plumbing
Official shall authorize the refunding of fees as follows:
| ||
"1.
|
The full amount of any fee paid hereunder which
was erroneously paid or collected.
| |
"2.
|
Not more than 75% of the permit fee paid when
no work has been done under a permit issued in accordance with this
code.
| |
"3.
|
Not more than 75% of the plan review fee paid
when an application for a permit for which a plan review fee has been
paid is withdrawn or canceled before any plan review effort has been
expended.
| |
"The Plumbing Official shall not authorize the
refunding of any fee paid except upon written application filed by
the original permittee not later than 180 days after the date of fee
payment."
|
"107.1 Required inspections and testing: The Plumbing Official shall conduct inspections during and upon
completion of the work for which a permit is issued. A record of all
such examinations and inspections and of all violations of this code
shall be maintained by the Plumbing Official. In order to facilitate
the making of inspections, every person to whom a permit is issued
under this code, or his agents, shall notify the Plumbing Official
that work is to commence under the permit within 24 hours prior to
the commencement of that work."
|
"108.2 Notice of violation: The
Plumbing Official shall serve a notice of violation or order to the
person responsible for the erection, installation, alteration, extension,
repair, removal or demolition of plumbing work in violation of any
provision of this code, or in violation of a detailed statement or
the approved construction documents thereunder, or in violation of
a permit or certificate issued under this code. The notice of a violation
or order shall direct the discontinuance of the illegal action or
condition and the abatement of the violation and shall allow a reasonable
time for the initiation and correction or the remedial action required,
except where emergency conditions exist which require immediate corrective
action."
|
"108.3 Prosecution of violation: If the notice of violation is not complied with within the time
stated in the notice, the Plumbing Official shall request the Borough
Solicitor to institute the appropriate proceeding by law or in equity
to restrain, correct or abate the violation, or to require the removal
or termination of the unlawful occupancy of the structure in violation
of this code or of the order or direction made pursuant thereto."
|
"108.4 Violation penalties: Any
person who violates any provision of this code or who fails to comply
with any requirement of this code or who erects, installs, alters
or repairs plumbing work in violation of the approved construction
documents, or of a permit or certificate issued under the provisions
of this code, shall be guilty of an offense; and for every such offense
shall, upon conviction, be sentenced to pay a fine of not less than
$50 or more than $1,000 and costs of prosecution; and in default of
payment of fine and costs, to undergo imprisonment for not more than
30 days. Provided: The imposition of one penalty for any such violation
shall not excuse the violation or permit it to continue, and all such
persons shall be required to correct or remedy every such violation
or defect within a reasonable time, and when not otherwise specified,
each 10 days that such prohibited conditions are maintained shall
constitute a separate offense."
|
"108.5 Stop-work orders: Upon notice
from the Plumbing Official, work on any plumbing system that is being
done contrary to the provisions of this code or is being done in a
dangerous or unsafe manner shall immediately cease. That notice shall
be in writing and shall be given to the owner of the property or to
the owner's agent or to the person doing the work. The notice shall
state the conditions under which work is authorized to be resumed.
Where an emergency exists, the Plumbing Official shall not be required
to give a written notice prior to stopping the work. Any person who
continues any work in or about a structure after having been served
with a stop-work order, except such work as that person is directed
to perform to remove a violation or unsafe condition, shall be subject
to a fine of not less than $200 or more than $1,000, and costs, and,
in default of payment of fine and costs, to undergo imprisonment for
not more than 30 days."
|
"305.6 Freezing: A water, soil
or waste pipe shall not be installed outside of a building, in attics
or crawl spaces, concealed in outside walls or in any place subjected
to freezing temperature, unless adequate provision is made to protect
them from freezing by insulation or heat or both. Water service piping
shall be installed below recorded frost penetration but not less than
three feet below grade."
|
"305.6.1 Sewer depth: Building
sewers that connect to private sewage disposal systems and laterals
shall be a minimum of 30 inches below finished grade at the point
of septic tank connection or connection to the public sewer line.
Building sewers shall have a minimum of 30 inches depth below grade."
|
"702.2 Sewer required: Every building
in which plumbing fixtures are installed and every premises having
drainage piping shall be connected to a public sewer, where available,
or an approved private sewage disposal system. A public sewer shall
be considered available to a structure where the structure is located
within 150 feet of the public sewer line."
|
"904.1 Roof extension: All open
vent pipes that extend through a roof shall be terminated at least
12 inches above the roof, except that where a roof is to be used for
any purpose other than weather protection, the vent extensions shall
be run at least seven feet above the roof."
|