[CC 1990 §20-105; Ord. No. 341, 5-9-2001]
A. The
subdivider shall submit to the Director of Public Works the following
plans, profiles and cross sections, drawn to a horizontal scale of
one (1) inch to one hundred (100) feet or less and a vertical scale
of one (1) inch to twenty (20) feet or less, and specifications for
the construction of the improvements for the subdivision as required
in this regulation. All elevations shall be referred to mean sea level.
1. The plan and profile of each street with tentative grades and street
intersection elevations.
2. The cross sections of proposed streets showing the width of roadways,
present and proposed grade lines, and location and size of utility
mains. The cross sections shall be taken and platted at intervals
of not more than one hundred (100) feet along the centerline, unless
otherwise required by the Director of Public Works, and shall extend
out to the sides to that point where the proposed grade intersects
the existing grade. In no case shall these cross sections be extended
less than the full width of the right-of-way.
3. The plan and profile of proposed sanitary sewers and storm water
sewers with grades and pipe sizes indicated, and a plan of the proposed
water distribution system showing pipe sizes and location of valves
and fire hydrants.
4. Specifications for the required improvements. Standard specifications
approved by the Director of Public Works may be used.