Minimum Parking Spaces and Aisle Dimensions
| |||
---|---|---|---|
Parking Angle
(X)
|
A
|
B
|
C
|
30º
|
11'-0"
|
17'-9 1/2"
|
18'-0"
|
45º
|
13'-0"
|
20'-6"
|
12'-9"
|
60º
|
18'-0"
|
21'-10"
|
10'-4 1/2"
|
70º
|
19'-0"
|
21'-10 1/2"
|
9'-7"
|
60º
|
25'-0"
|
21'-3"
|
9'-1 1/2"
|
90º
|
25'-0"
|
20'-0"
|
9'-0"
|
NOTE: THE MAXIMUM PERMISSIBLE SLOPE OF ANY PARKING AREA SHALL
BE 5%.
|
Table 11 — Parking Ratios
| |
---|---|
Parking Ratios
| |
Land Use/Activity
|
Minimum Vehicle Spaces
|
Residential Buildings
| |
Conversion dwellings
|
2 per dwelling unit
|
Duplex
|
2 per dwelling unit
|
Group home
|
1 for every three beds plus one for each employee
|
Manufactured housing, residential design
|
2 per dwelling unit
|
Mobile home park
|
2 per dwelling unit
|
Multifamily dwellings
|
1.2 per dwelling unit
|
Quadruplex
|
2 per dwelling unit
|
Single-family
|
2 per dwelling unit
|
Townhouses
|
2 per dwelling unit
|
Hotels, Motels or Other Accommodation
| |
Bed-and-breakfast
|
1 per guest room and 2 spaces for owner
|
Extended stay hotel/motel
|
1 per room plus 1 space per employee and 1 per 800 square feet
of public meeting area
|
Hotel, motel
|
1 per room plus 1 space per employee and 1 per 800 square feet
of public meeting area
|
Rooming and boarding house
|
1 per guest room plus 2 spaces for owner's portion
|
Commercial
| |
Adult business
|
Parking demand analysis to be performed by a traffic engineering
firm
|
After hours club
|
1 per 200 square feet GFA
|
Airport
|
1 per 4 seating accommodations for waiting passengers plus 1
per each 2 employees
|
Amusement park
|
1 per 600 square feet outdoor recreation area
|
Animal cemetery
|
1 per acre, but not less than 5 spaces
|
Animal day care
|
1 per 600 square feet GFA plus 1 per employee
|
Animal groomer
|
2 per grooming station plus one per employee
|
Art and craft studio
|
1 per each 200 square feet of floor area
|
Auditorium
|
1 per each 2 seats in the main seating area
|
Automobile repair and service
|
3 per repair bay and 1 per each employee
|
Bakery
|
1 per 300 square feet GFA
|
Beverage distributor
|
1 per 300 square feet GFA
|
Book store
|
1 per 300 square feet GFA
|
Car rental
|
1 per 375 square feet GFA of sales and service building
|
Car wash
|
1 per 375 square feet GFA, including service bays, wash tunnels,
and retail areas
|
Catering
|
1 per 300 square feet GFA
|
Cemetery and mausoleums
|
1 per each employee and ample accessways to the cemetery sections
so as to allow parking on the accessway for gravesite services and
visitations
|
Commercial recreation-indoor
|
1.5 per 500 square feet GFA
|
Commercial recreation, outdoor
|
1 per each 3 participants at maximum utilization
|
Communication antenna
|
1 per service employee
|
Conference center
|
1 per 5 seats or 1 per 300 square feet GFA if no permanent seats
|
Convenience stores or centers
|
1 per 300 square feet GFA
|
Custom printing
|
1 per 300 square feet GFA
|
Department stores
|
1 per 300 of GFA
|
Drive-through facilities
|
1 per 250 square feet GFA
|
Drug store
|
1 per each 200 square feet of floor area
|
Financial institution
|
1 per 300 square feet GFA
|
Flea market
|
1 per 300 square feet of outdoor display area
|
Funeral home
|
1 per 4 seats
|
Garden center
|
1 per 1,000 square feet
|
Gas station
|
1 per 375 square feet GFA including service bays, wash tunnels
and retail areas
|
Golf course
|
6 per hole
|
Hardware store
|
1 per each 200 square feet of floor area
|
Kennel
|
1 per each employee on the maximum shift and 1 per each 200
square feet of area devoted to the kennel area
|
Laundromat
|
1 per 300 square feet GFA
|
Lumberyard
|
1 per 375 square feet GFA of sales and service building
|
Manufactured home sales
|
1 per 300 square feet GFA of sales building
|
Massage establishment
|
1 per each 200 square feet of floor area
|
Micro brewery
|
1 per 75 square feet GFA
|
Nightclub
|
1 per 2 seats
|
Office, business and professional
|
1 per each 300 square feet of floor area
|
Outdoor advertising sign
|
1 space
|
Pawnshop
|
1 per each 200 square feet of floor area
|
Personal services
|
1 per each 200 square feet of floor area
|
Post office
|
1 per employee
|
Recording studio
|
1 per 300 square feet GFA
|
Restaurant
|
1 per 75 square feet GFA
|
Restaurant, drive-through
|
1 per 75 square feet GFA
|
Retail store
|
1 per each 200 square feet of floor area
|
Shopping center (3 plus acres)
|
1 per 300 square feet GFA
|
Tattoo parlor
|
1 per 300 GFA
|
Tavern or bar
|
1 per 2 seats
|
Tobacco establishment
|
1 per 200 GFA
|
Vehicle/boat/equipment sales
|
1 per each 2,000 square feet of lot area for employee and customer
parking (excludes vehicle display area)
|
Veterinarian office
|
1 per each 400 square feet of floor area
|
Warehouse/discount store
|
1 per 300 square feet GFA
|
Industrial
| |
Asphalt plant
|
1 per employee on max shift
|
Automotive wrecking and graveyards, salvage yards, and junkyards
|
1 per employee
|
Commercial motor vehicle repair
|
3 per repair bay and 1 per each employee
|
Constructions-related businesses
|
1 per 1,000 square feet GFA
|
Laboratory or specialized industrial facility
|
1 per 300 square feet GFA
|
Large area distribution or transit warehouse
|
1 per 1,000 square feet GFA
|
Light industrial structures and facilities
|
1 per 1,000 square feet GFA
|
Manufacturing facility
|
1 per 1,000 square feet GFA
|
Mini-warehouse
|
4 spaces plus 2 for manager's quarters
|
Process plants (metals chemicals etc.)
|
1 per 300 square feet GFA
|
Recycling business
|
1 per employee
|
Refrigerated warehouse and cold storage
|
1 per 1,000 square feet GFA
|
Research and development
|
1 per 500 square feet of GFA
|
Tank farms
|
1 per 1,000 square feet GFA
|
Warehouse and storage services (including distribution)
|
1 per 1,000 square feet GFA
|
Public Assembly
| |
Clubs and lodges
|
1 per 3 persons
|
Community center
|
1 per 300 square feet gross
|
Exhibition, convention, or conference structure
|
1 per 1,000 square feet GFA
|
Place of worship
|
1 per 8 seats
|
Institutional or Community Facility
| |
Animal hospitals
|
1 per employee
|
Assisted living facilities
|
1 per 3 rooms
|
Aquarium/zoo facility
|
1 per 1,000 square feet GFA
|
College or university facility
|
1 per 4 students
|
Day-care center
|
1 per 375 square feet GFA
|
Dormitories
|
1 per 4 students
|
Exhibitions and art galleries
|
1 per 500 square feet of GFA
|
Group care facility
|
1 per 3 rooms
|
Hospital building
|
1 per 400 square feet GFA
|
Life care or continuing care services
|
1 per 3 rooms
|
++Medical and dental offices
|
1 space per employee plus 4 spaces per doctor or practitioner
on duty at any given time
|
Methadone treatment center
|
1 per each 200 square feet of floor area
|
Nursing home
|
1 per 3 rooms
|
Public clinic, medical
|
1 per each 200 square feet of floor area
|
Retirement housing facility
|
1 per three dwelling units
|
School
|
1 per classroom
|
Skilled nursing
|
1 per 3 rooms
|
Trade or specialty school
|
1 per 200 feet
|
Government Uses
| |
Ambulance facility
|
1 per employee plus 1 per 200 square feet GFA
|
Correctional or rehabilitation facility
|
1 per employee on maximum shift, 1 per service vehicle
|
Emergency operation center
|
1 per employee
|
Fire station
|
1 per employee + 1 per each 3 volunteer personnel on normal
shift + 1 per 200 square feet usable office space
|
Library
|
1 per 300 square feet GFA
|
Magistrate office
|
1 per 300 square feet GFA
|
Municipal building
|
1 per 300 square feet GFA
|
Park
|
Parking demand analysis
|
Police station
|
1 per employee plus 1 per each 3 volunteer personnel on normal
shift plus 1 per 200 square feet usable office space
|
Salt storage facility
|
1 per employee
|
Transportation-related Facilities
| |
Airport control tower
|
1 per employee
|
Airport maintenance and hangar facility
|
1 per employee
|
Airport terminal
|
1 per 4 seating accommodations for waiting passengers plus 1
per each 2 employees
|
Automobile parking
|
1 per employee
|
Bus or truck maintenance facility
|
1 per employee
|
Bus terminal
|
1 per employee plus spaces required to satisfy projected peak
parking needs
|
Courier and messenger services
|
1 per employee
|
Heliport facility
|
1 per 4 seating accommodations for waiting passengers plus 1
per each 2 employees
|
Multistoried parking structure
|
Not applicable
|
Park and ride facility
|
Not applicable
|
Taxi and limousine service
|
1 per employee
|
Towing and other road services
|
1 per employee
|
Truck or freight transportation services
|
1 per employee
|
Utility Uses
| |
Co-location - communication facility
|
1 per service employee
|
Essential facilities
|
None
|
Gas or electric power generation facility
|
1 per employee
|
Hazardous waste collection
|
1 per employee
|
Hazardous waste treatment and disposal
|
1 per employee
|
Incinerator, or similar facility
|
1 per employee
|
Large solar energy production facility
|
1 per service employee
|
Large wind energy production facility
|
1 per service employee
|
Radio, television, or wireless transmitter
|
1 per service employee
|
Railroad facility
|
1 per employee
|
Sewer treatment plan
|
1 per employee
|
Solid waste transfer station
|
1 per employee
|
Solid waste combustor or incinerator
|
1 per employee
|
Solid waste landfill facility
|
1 per employee
|
Tower-based wireless communications facility (outside right-of-way)
|
1 per service
|
Water supply pump station
|
1 per employee
|
Water supply-related facility
|
1 per employee
|
Water tank (elevated, at grade, underground)
|
1 per service employee
|
Agriculture, forestry, fishing, and hunting
| |
Animal production, including slaughter
|
1 per 300 square feet GFA
|
Farmers market
|
1 per 300 square feet GFA
|
Forestry and logging
|
None
|
Grain silos and other storage structure for grains and agricultural
products
|
1 per 300 square feet GFA
|
Greenhouses/nurseries
|
1 per 375 square feet GFA
|
Hatcheries and poultry houses
|
1 per 300 square feet GFA
|
Livestock pens or hog houses
|
1 per 300 square feet GFA
|
Stables and other equine-related facilities
|
1 per 300 square feet GFA
|
Mining and extraction establishments
| |
Coal
|
1 per employee plus one per facility vehicle
|
Metals (iron, copper, etc)
|
1 per employee plus one per facility vehicle
|
Natural gas compressor station
|
1 per employee plus one per facility vehicle
|
Natural gas processing plant
|
1 per employee plus one per facility vehicle
|
Nonmetallic mining
|
1 per employee plus one per facility vehicle
|
Oil or gas well
|
1 per employee plus one per facility vehicle
|
Quarrying and stone cutting
|
1 per employee plus one per facility vehicle
|
TABLE 12 — Berths Required (Retail, Industrial or
Manufacturing)
| ||
---|---|---|
Gross Floor Area
(square feet)
|
Number of Berths Required
| |
Under 10,000
|
None
| |
10,000 to 19,999
|
1
| |
20,000 to 39,999
|
2
| |
40,000 to 65,000
|
3
| |
For each additional 20,000
|
1 additional
|
Table 13 — Berths Required (Auditoriums, Convention
Halls, Office Buildings)
| |
---|---|
Gross Floor Area
(square feet)
|
Number of Berths Required
|
Under 40,000
|
None
|
40,000 to 59,999
|
1
|
60,000 to 99,999
|
2
|
100,000 to 160,000
|
3
|
Over 160,000
|
4
|