Within any identified floodplain area, any new construction or substantial improvements shall be prohibited. If a variance is obtained for new construction or substantial improvements in the identified floodplain area in accordance with the criteria in Article
VIII, then the following provisions apply:
A. Residential structures.
(1) In A Zones, where there are no base flood elevations specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation determined in accordance with §
113-18A of this chapter.
(2) The design and construction standards and specifications contained
in the 2009 International Building Code (IBC) and in the 2009 International
Residential Code (IRC), or the most recent revisions thereof, and
ASCE 24 and 34 Pa. Code (Chapters 401 through 405, as amended) shall
be utilized where they are more restrictive.
B. Nonresidential structures.
(1) In A Zones, where no base flood elevations are specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation determined in accordance with §
113-18A of this chapter, or be designed and constructed so that the space enclosed below the regulatory flood elevation:
(a)
Is floodproofed so that the structure is watertight with walls
substantially impermeable to the passage of water; and
(b)
Has structural components with the capability of resisting hydrostatic
and hydrodynamic loads and effects of buoyancy.
(2) Any nonresidential structure, or part thereof, made watertight below
the regulatory flood elevation shall be floodproofed in accordance
with the W1 or W2 space classification standards contained in the
publication entitled "Flood Proofing Regulations," published by the
U.S. Army Corps of Engineers (June 1972, as amended March 1992), or
with some other equivalent standard. All plans and specifications
for such floodproofing shall be accompanied by a statement certified
by a registered professional engineer or architect which states that
the proposed design and methods of construction are in conformance
with the above referenced standards.
(3) The design and construction standards and specifications contained
in the 2009 International Building Code (IBC) and in the 2009 International
Residential Code (IRC), or the most recent revisions thereof, and
ASCE 24 and 34 Pa. Code (Chapters 401 through 405, as amended) shall
be utilized where they are more restrictive.
C. Space below the lowest floor.
(1) Fully enclosed space below the lowest floor (including basements)
is prohibited.
D. Historic structures. Historic structures undergoing repair or rehabilitation
that would constitute a substantial improvement, as defined in this
chapter, must comply with all chapter requirements that do not preclude
the structure's continued designation as an historic structure.
Documentation that a specific ordinance requirement will cause removal
of the structure from the National Register of Historic Places or
the State Inventory of Historic places must be obtained from the Secretary
of the Interior or the State Historic Preservation Officer. Any exemption
from chapter requirements will be the minimum necessary to preserve
the historic character and design of the structure.
The following minimum standards shall apply for all construction
and development proposed within any identified floodplain area:
A. Fill.
(1) Within any identified floodplain area, the use of fill shall be prohibited. If a variance is obtained in accordance with the criteria in Article
VIII, then the following provisions apply. If fill is used, it shall:
(2) Extend laterally at least 15 feet beyond the building line from all
points;
(3) Consist of soil or small rock materials only; sanitary landfills
shall not be permitted;
(4) Be compacted to provide the necessary permeability and resistance
to erosion, scouring, or settling;
(5) Be no steeper than one vertical to two horizontal feet unless substantiated
data justifying steeper slopes are submitted to, and approved by,
the Floodplain Administrator; and
(6) Be used to the extent to which it does not adversely affect adjacent
properties.
B. Drainage facilities. Storm drainage facilities shall be designed
to convey the flow of stormwater runoff in a safe and efficient manner.
The system shall ensure proper drainage along streets, and provide
positive drainage away from buildings. The system shall also be designed
to prevent the discharge of excess runoff onto adjacent properties.
C. Water and sanitary sewer facilities and systems.
(1) All new or replacement water supply and sanitary sewer facilities
and systems shall be located, designed and constructed to minimize
or eliminate flood damages and the infiltration of floodwaters.
(2) Sanitary sewer facilities and systems shall be designed to prevent
the discharge of untreated sewage into floodwaters.
(3) No part of any on-site waste disposal system shall be located within
any identified floodplain area except in strict compliance with all
state and local regulations for such systems. If any such system is
permitted, it shall be located so as to avoid impairment to it, or
contamination from it, during a flood.
(4) The design and construction provisions of the UCC and FEMA No. 348,
"Protecting Building Utilities From Flood Damages" and "The International
Private Sewage Disposal Code" shall be utilized.
D. Other utilities. All other utilities such as gas lines, electrical
and telephone systems shall be located, elevated (where possible)
and constructed to minimize the chance of impairment during a flood.
E. Streets. The finished elevation of all new streets shall be no more
than one foot below the regulatory flood elevation.
F. Storage. All materials that are buoyant, flammable, explosive, or in times of flooding could be injurious to human, animal, or plant life, and not listed in §
113-25, Development which may endanger human life, shall be stored at or above the regulatory flood elevation or floodproofed to the maximum extent possible.
G. Placement of buildings and structures. All buildings and structures
shall be designed, located, and constructed so as to offer the minimum
obstruction to the flow of water and shall be designed to have a minimum
effect upon the flow and height of floodwater.
H. Anchoring.
(1) All buildings and structures shall be firmly anchored in accordance
with accepted engineering practices to prevent flotation, collapse,
or lateral movement.
(2) All air ducts, large pipes, storage tanks, and other similar objects
or components located below the regulatory flood elevation shall be
securely anchored or affixed to prevent flotation.
I. Floors, walls and ceilings.
(1) Wood flooring used at or below the regulatory flood elevation shall
be installed to accommodate a lateral expansion of the flooring, perpendicular
to the flooring grain, without causing structural damage to the building.
(2) Plywood used at or below the regulatory flood elevation shall be
of a marine or water-resistant variety.
(3) Walls and ceilings at or below the regulatory flood elevation shall
be designed and constructed of materials that are water-resistant
and will withstand inundation.
(4) Windows, doors, and other components at or below the regulatory flood
elevation shall be made of metal or other water-resistant material.
J. Paints and adhesives.
(1) Paints and other finishes used at or below the regulatory flood elevation
shall be of marine or water-resistant quality.
(2) Adhesives used at or below the regulatory flood elevation shall be
a marine or water-resistant variety.
(3) All wooden components (doors, trim, cabinets, etc.) used at or below
the regulatory flood elevation shall be finished with a marine or
water-resistant paint or other finishing material.
K. Electrical components.
(1) Electrical distribution panels shall be at least three feet above
the base flood elevation.
(2) Separate electrical circuits shall serve lower levels and shall be
dropped from above.
L. Equipment. Water heaters, furnaces, air-conditioning and ventilating
units, and other electrical, mechanical or utility equipment or apparatus
shall not be located below the regulatory flood elevation.
M. Fuel supply systems. All gas and oil supply systems shall be designed
to prevent the infiltration of floodwaters into the system and discharges
from the system into floodwaters. Additional provisions shall be made
for the drainage of these systems in the event that flood water infiltration
occurs.
N. Uniform Construction Code coordination. The standards and specifications
contained in 34 Pa. Code (Chapters 401 through 405 as amended) and
not limited to the following provisions shall apply to the above and
other sections and subsections of this chapter, to the extent that
they are more restrictive and supplement the requirements of this
chapter.
(1) International Building Code (IBC) 2009 or the latest edition thereof:
Secs. 801, 1202, 1403, 1603, 1605, 1612, 3402, and Appendix G.
(2) International Residential Building Code (IRC) 2009 or the latest
edition thereof: Secs. R104, R105, R109, R322, Appendix E, and Appendix
J.
Within any identified floodplain area, any structure of the
kind described in Subsection A below shall be prohibited. No variance
shall be granted.
A. In accordance with the Pennsylvania Flood Plain Management Act, and the regulations adopted by the Department of Community
and Economic Development as required by the Act, any new or substantially
improved structure which will be used for the production or storage
of any of the following dangerous materials or substances, or will
be used for any activity requiring the maintenance of a supply of
more than 550 gallons, or other comparable volume, of any of the following
dangerous materials or substances on the premises, or will involve
the production, storage, or use of any amount of radioactive substances
shall be subject to the provisions of this section, in addition to
all other applicable provisions. The following list of materials and
substances are considered dangerous to human life:
(11)
Nitric acid and oxides of nitrogen.
(12)
Petroleum products (gasoline, fuel oil, etc.).
(16)
Sulphur and sulphur products.
(17)
Pesticides (including insecticides, fungicides, and rodenticides).
(18)
Radioactive substances, insofar as such substances are not otherwise
regulated.
All subdivision proposals and development proposals containing
at least 50 lots or at least five acres, whichever is the lesser,
in identified floodplain areas where base flood elevation data are
not available, shall be supported by hydrologic and hydraulic engineering
analyses that determine base flood elevations and floodway information.
The analyses shall be prepared by a licensed professional engineer
in a format required by FEMA for a conditional letter of map revision
and letter of map revision. Submittal requirements and processing
fees shall be the responsibility of the applicant.
Within any identified floodplain area, manufactured homes shall be prohibited. If a variance is obtained in accordance with the criteria in Article
VIII, then the following provisions apply:
A. Within any identified floodplain area, manufactured homes shall be
prohibited within the area measured 50 feet landward from the top-of-bank
of any watercourse.
B. Where permitted within any identified floodplain area, all manufactured
homes, and any improvements thereto, shall be:
(1) Placed on a permanent foundation;
(2) Elevated so that the lowest floor of the manufactured home is at
least 1 1/2 feet above base flood elevation;
(3) Anchored to resist flotation, collapse, or lateral movement; and
(4) Have all ductwork and utilities, including HVAC/heat pump, elevated
to the regulatory flood elevation.
C. Installation of manufactured homes shall be done in accordance with
the manufacturers' installation instructions as provided by the
manufacturer. Where the applicant cannot provide the above information,
the requirements of Appendix E of the 2009 International Residential
Building Code or the U.S. Department of Housing and Urban Development's
Permanent Foundations for Manufactured Housing, 1984 Edition, draft
or latest revision thereto, and 34 Pa. Code Chapters 401 through 405
shall apply.
D. Consideration shall be given to the installation requirements of
the 2009 IBC, and the 2009 IRC, or the most recent revisions thereto,
and 34 Pa. Code, as amended where appropriate and/or applicable to
units where the manufacturers' standards for anchoring cannot
be provided or were not established for the proposed unit(s) installation.
Within any identified floodplain area, recreational vehicles shall be prohibited. If a variance is obtained in accordance with the criteria in Article
VIII, then the following provisions apply:
A. Recreational vehicles in Zones A, A1-30, AH and AE must either:
(1) Be on the site for fewer than 180 consecutive days; and
(2) Be fully licensed and ready for highway use; or
(3) Meet the permit requirements for manufactured homes in §
113-27.