Table 3. Applicability of Soil Erosion and Sediment
Control Performance Standards**
[Amended 9-6-2016 by Ord. No. 7290] | ||||||
---|---|---|---|---|---|---|
Type of Development
|
Basic Requirements
(Subsection A)
|
Requirements for Development Disturbing 1 Acre
or More
(Subsection B)
|
Channel Requirements
(Subsection C)
|
Inspections and Maintenance Requirements
(Subsection D)
|
Notification Requirements
(Subsection E)
|
Special Precautions
(Subsection F)
|
General permit
|
Waived*
|
N/A
|
Waived*
|
Waived*
|
Waived*
|
Waived*
|
Minor
|
X
|
N/A
|
If channel construction included
|
X
|
X
|
X
|
Intermediate
|
X
|
N/A
|
If channel construction included
|
X
|
X
|
X
|
Major
|
X
|
X
|
If channel construction included
|
X
|
X
|
X
|
Public road
|
X
|
If development greater than 1 acre
|
If channel construction included
|
X
|
X
|
X
|
Mining
|
X5
|
If development greater than 1 acre
|
If channel construction included
|
X
|
X
|
X
|
Flood hazard area
|
X
|
If development greater than 1 acre
|
If channel construction included
|
X
|
X
|
X
|
Wetland
|
X
|
If development greater than 1 acre
|
If channel construction included
|
X
|
X
|
X
|
5
|
Requirements may be waived by the enforcement officer
for portions of the development site that do not drain off site.
|
*
|
Refer to the Performance Standards and Terms and Conditions
of Specified Development of the specific General Permit.
|
**
|
See the Crystal Lake Watershed Design Manual and Crystal
Lake Watershed Stormwater Management Program Implementation Plan for
Soil Erosion and Sediment Control Performance Standards in the Crystal
Lake Watershed
|
where "n" is Manning's roughness factor, "A" is the effective
flow area of the cross-section, and "R" is the ratio of the area to
the wetted perimeter.
|
Table 4. Minimum Elevation Standards for Public
Health Protection
| |||||||
---|---|---|---|---|---|---|---|
Type of Flood Hazard Area
|
Storage of Materials Outside a Building
Subsection J(1)
|
Water Supply Systems
Subsection J(2)
|
Sanitary Sewers
Subsection J(2)
|
Wells
Subsection J(3)
|
New On-Site Waste Disposal Systems
Subsection J(4)
|
Replacement On-Site Waste Disposal Systems
Subsection J(5)
|
Wastewater Treatment Plants
Subsection J(5)
|
Flood-prone area
|
Waived
|
Waived
|
Waived
|
Waived
|
Waived
|
Waived
|
FPE
|
Floodplain: flood fringe and floodway
|
BFE
|
FPE
|
FPE
|
FPE
|
N/A
|
Waived
|
FPE
|
Table 5. Building Protection Standards for Flood Hazard
Areas
| |||
---|---|---|---|
Type of Building
|
Type of Flood Hazard Area
|
Flood Protection Elevation
(feet above BFE)
|
Lowest Floor Elevation
(feet above BFE)6
|
Residential
|
Flood-prone area
|
2
|
2
|
Floodplain
|
2
|
2
| |
Attached garage
|
Flood-prone area
|
0.5
|
0.5
|
Floodplain
|
0.5
|
0.5
| |
Accessory
|
Flood-prone area
|
2
|
<BFE
|
Floodplain
|
2
|
0.5
| |
Small accessory
|
Flood-prone area
|
0.5
|
<BFE
|
Floodplain
|
0.5
|
<BFE
| |
Nonresidential
|
Flood-prone area
|
2
|
2
|
Floodplain
|
2
|
2
| |
Agricultural
|
Flood-prone area
|
2
|
<BFE
|
Floodplain
|
2
|
<BFE
|
6
|
This requirement does not apply to dry floodproofed buildings.
|
Table 6. Acceptable Measures for Flood Protection
| |||||
---|---|---|---|---|---|
Type of Building
|
Type of Flood Hazard Area
|
Construction on Permanent Fill
Subsection K(2)(a)
|
Elevation on Crawl Space, Stilts, Piles, Walls, etc.
Subsection K(2)(b)
|
Dry Flood- proofing
Subsection K(2)(c)
|
Wet Flood- proofing
Subsection K(2)(d)
|
Residential
|
Flood-prone area
|
YES
|
NO
|
YES
|
NO
|
Floodplain
|
YES
|
NO
|
NO
|
NO
| |
Attached garage
|
Flood-prone area
|
YES
|
NO
|
YES
|
NO
|
Floodplain
|
YES
|
NO
|
NO
|
NO
| |
Accessory
|
Flood-prone area
|
YES
|
NO
|
YES
|
YES
|
Floodplain
|
YES
|
NO
|
YES
|
NO
| |
Small accessory
|
Flood-prone area
|
YES
|
NO
|
YES
|
YES
|
Floodplain
|
YES
|
NO
|
YES
|
YES
| |
Nonresidential
|
Flood-prone area
|
YES
|
NO
|
YES
|
NO
|
Floodplain
|
YES
|
NO
|
YES
|
NO
| |
Agricultural
|
Flood-prone area
|
YES
|
NO
|
YES
|
YES
|
Floodplain
|
YES
|
NO
|
YES
|
YES
|
FIGURE 1
| |
---|---|
How to Elevate Your Floodplain Building*
| |
(IDNR Floodplain Management in Illinois Quick Guide, 2001)
| |
*Note: The Crystal Lake Stormwater Ordinance recognizes elevation
on fill only and does not allow elevation by crawl space, piles, stilts,
walls, etc.
|
Table 7. Compensatory Storage Exemptions
| |||||
---|---|---|---|---|---|
Type of Flood Hazard Area
|
Fill Less than 5 Cubic Yards
Subsection M(1)(a)
|
Replacement Septic Systems and Wells
Subsection M(1)(b)
|
Floodproofing Habitable Buildings
Subsection M(1)(c)
|
Artificially Created Storage
Subsection M(1)(d)
|
All Other Regulated Development
Subsection M(2)
|
Flood-prone area
|
Exempt
|
Exempt
|
Exempt
|
Exempt
|
Not exempt
|
Floodplain: flood fringe
|
Exempt
|
Exempt
|
Exempt
|
Exempt
|
Not exempt
|
Floodplain: designated or nondesignated floodway
|
Not exempt
|
Not exempt
|
Exempt
|
Exempt
|
Not exempt
|
Table 8. Required Compensatory Storage Ratios
| ||||
---|---|---|---|---|
Type of Flood Hazard Area
|
Regulated Development without As-Builts7
|
Regulated Development with As-Builts
|
Public Road Development
| |
Riverine floodplain
|
1.5:1
|
1.2:1
|
Minimum 1:1
| |
Riverine flood-prone area
|
1.5:1
|
1.2:1
|
Minimum 1:1
| |
Non-riverine floodplain
|
1:1
|
1:1
|
1:1
| |
Non-riverine flood-prone area
|
1:1
|
1:1
|
1:1
|
7
|
As-built plans shall be required for any regulated development
resulting in 100 cubic yards or more of fill in a flood hazard area.
|
Table 9. IWMC Mitigation Ratios
| |||||||||
---|---|---|---|---|---|---|---|---|---|
Category
|
IWMC Quality
|
Impact Area
(acres)
|
Regulated Develop- ment Type
|
Sub- section
E(1)
|
Sub- section
E(3)(a)
|
Sub- section E(3)(b)
|
Sub- section
E(3)(c)
|
Sub- section
E(3)(d)
|
Sub- section
E(3)(e)
|
I
|
Any
|
<0.10
|
Any
|
Exempt
| |||||
I
|
Standard8
|
0.1-1.0
|
Any
|
1.5:1 or 1:1
| |||||
II
|
Standard8
|
1.0-2.0
|
Any
|
1.5:1 or 1:1
| |||||
III
|
Standard8
|
>2.0
|
Any
|
1.5:1 or 1:1
| |||||
III
|
HFVW
|
Any
|
Any
|
3:19
| |||||
III
|
HQAR or HQHS
|
Any
|
Any
|
5:19
| |||||
Impacts prior to permit issuance
|
5:19
| ||||||||
IV
|
Any
|
Any
|
Restoration, creation, and enhance- ment
|
1:1
| |||||
V
|
Any
|
Any
|
Temporary impact
|
1:1
|
8
|
"Standard" means any IWMC that is not a HFVW, HQAR,
or HQHS.
|
9
|
May be reduced to 1:1. Refer to Subsection D(5)(c)[6].
|
Table 10. Buffer Widths
| ||||||
---|---|---|---|---|---|---|
Buffer Type
|
Criteria
|
Subsection A(2)(a)
|
Subsection A(2)(b)
|
Subsection A(3)(a)
|
Subsection A(3)(b)
|
Subsection A(3)(c)
|
Linear
|
Tributary area > 20 acres
|
50 feet
| ||||
Linear
|
HFVW, HQHS, or HQAR
|
100 feet
| ||||
Nonlinear
|
0.25 acre < surface area < 0.50 acre
|
30 feet
| ||||
Nonlinear
|
0.50 acre < surface area
|
50 feet
| ||||
Nonlinear
|
HFVW, HQHS, or HQAR
|
100 feet
|