Minimum Slope in Feet per 100 Feet
| ||
---|---|---|
Sewer Size
|
Ductile Iron
|
PVC
|
8-inch
|
0.40
|
0.30
|
10-inch
|
0.28
|
0.20
|
12-inch
|
0.22
|
0.15
|
15-inch
|
0.15
|
0.10
|
18-inch
|
0.12
|
0.075
|
21-inch
|
0.10
|
0.06
|
24-inch or above
|
0.08
|
0.05
|
Table I
Minimum Duration For Air Test Pressure Drop
| ||
---|---|---|
Pipe Size
|
Time
(minutes)
| |
Inches
|
Millimeters
| |
4
|
100
|
2 1/2
|
6
|
150
|
4
|
8
|
200
|
5
|
10
|
225
|
6 1/2
|
12
|
305
|
7 1/2
|
15
|
380
|
9 1/2
|
Section 603: Inlets and Manholes.
|
Processor
|
171CCC76010
|
TOD
|
Option Adapter
|
I/O Base 1
|
ANR 120-90
|
I/O Base 2
|
ADM 350-10
|
Com. Adapter
|
170INT 11000
|
*Table 1
Time Requirements for Air Testing For Sewer Line of Uniform
Pipe Size
| ||
---|---|---|
Pipe Size
(inches)
|
Time
| |
Minutes
|
Seconds
| |
**4
|
2
|
32
|
**6
|
3
|
50
|
**8
|
5
|
6
|
10
|
6
|
22
|
12
|
7
|
39
|
14
|
8
|
56
|
15
|
9
|
35
|
16
|
10
|
12
|
18
|
11
|
34
|
20
|
12
|
45
|
21
|
13
|
30
|
NOTES:
| |
---|---|
*
|
Multi-pipe sizes: When sewer line undergoing test is eight-inch
or larger diameter pipe and includes different sized laterals, the
figure in Table 1 for uniform sewer main sizes will not give reliable
or accurate criteria for the test. Where multi-pipe sizes are to undergo
air testing, the Engineer will compute "average" size in inches which
is multiplied by 38.2 seconds. The results give minimum time in seconds
acceptable for pressure drop of 0.5 psig for "average" diameter pipe.
|
**
|
For eight-inch and smaller pipe only, if during the five-minute
stabilization period pressure drops less than 0.5 psig after initial
pressurization and air is not added, pipe section undergoing test
shall have passed.
|