Table 8: Buffer Type Standards
| ||
---|---|---|
Buffer Type
|
Land Uses
|
Minimum Buffer Yard Setback
|
Type A buffer
|
Minor separation shall be required between similar land developments
or compatible land uses.
|
20 feet
|
Type B buffer
|
Moderate separation shall be required between single-family
residential that is adjacent to more dense, smaller lot single-family,
multifamily housing or rural business centers.
|
30 feet
|
Type C buffer
|
Major separation shall be required between single-family residential
or multifamily housing that is adjacent to commercial areas, schools,
institutional, cultural facilities, regional commercial areas, hotels,
motels and office parks, or active recreation areas.
|
40 feet
|
Type D buffer
|
Major separation shall be required between single-family residential
or multifamily housing that is adjacent to adjacent land uses where
steep slopes of 15% or more are present.
|
75 feet separation between the land use and the steep slope
area
|
Table 9: Octave Bond Sound Pressure
| |
---|---|
Octave Band Center Frequency
(Hz)
|
Level
(dBa)
|
31.5
|
96
|
63
|
82
|
125
|
74
|
250
|
67
|
500
|
63
|
1,000
|
60
|
2,000
|
57
|
4,000
|
55
|
8,000
|
53
|
Table 10: Octave Bands
| |
---|---|
Octave Band Sound Pressure Level
(dBa)
|
Octave Band Center Frequency
(Hz)
|
31.5
|
86
|
63
|
71
|
125
|
61
|
250
|
53
|
500
|
48
|
1,000
|
45
|
2,000
|
42
|
4,000
|
40
|
8,000
|
38
|
PV = 6.28 F x D
|
Where:
| ||
PV
|
=
|
Particle velocity (inches per second).
|
F
|
=
|
Vibration frequency (cycles per second).
|
D
|
=
|
Single amplitude replacement of the vibrations (inches).
|
The three velocities shall be the vector sum of the three components
recorded.
|
Table 11: Maximum Ground-Transmitted Vibration
| ||
---|---|---|
Zone
|
Particle Velocity
(inches per second)
Adjacent Lot Line
|
Residential Zone
|
Commercial districts
|
0.10
|
0.02
|
Industrial districts
|
0.15
|
0.02
|
Residential districts
|
0.02
|
0.02
|
Table 12: Minimum Off Street Parking Requirements
| |
---|---|
Land Use/Activity
|
Minimum Vehicle Spaces
|
Adult and sexually oriented business
|
Determined as per parking demand analysis
|
Agricultural use/operation
|
1 per 200 square feet of gross leasable area of building used
for sale of products produced on the premises
|
Animal day care
|
1 per 600 square feet of floor area plus 1 per employee
|
Animal hospital and veterinary service
|
1 per employee on peak shift plus 1 per each 2 animal enclosures
|
Bed-and-breakfast establishment (B&B)
|
1 per each offered sleeping room plus 2 per each permanent resident
plus 1 per each employee on peak shift
|
Care facility and senior housing
| |
Life care community
|
2 per living unit plus 1 per each employee on peak shift
|
Nursing home
|
1 per each 4 beds plus 1 per each employee on peak shift
|
Car wash, principal
|
1 per each employee on the maximum shift and 1 per vehicle if
drop off service is offered, plus vehicle queue area
|
Cemetery
|
1 per employee and ample accessways to the cemetery sections
so as to allow parking on the accessway for gravesite services and
visitations
|
Civic club
|
1 per 300 square feet floor area
|
College/university
|
Parking demand analysis
|
Commercial or public parking garage or lot
|
Not applicable
|
Community center
|
1 per 300 square feet floor area
|
Day-care center
|
1 per employee on peak shift plus 1 per each 2 of the maximum
number of persons cared for at the center
|
Drive-through facility, principal
|
1 per employee on peak shift plus vehicle queue area
|
Drug and alcohol treatment facility
|
1 per 200 square feet of floor area
|
Dwelling types:
| |
Garden apartment
|
2 per apartment unit plus 0.5 spaces per unit for guest parking
|
Manufactured home
|
2 per dwelling unit
|
Single-family, detached
|
2 per dwelling unit
|
Single-family, attached (townhouse/row home)
|
2 per dwelling unit
|
Essential facility
|
1 per service vehicle that is necessary to service the facility
(if applicable) or 1 per employee plus 1 per each 3 volunteer personnel
on normal shift plus 1 per 200 square feet usable office space
|
Financial institution
|
1 per 300 square feet floor area plus 1 per employee plus 2
per drive-through lane
|
Forestry
|
None
|
Funeral home/mortuary
|
1 per 4 seats
|
Gas/fuel station
|
1 per 200 square feet floor area, including service bays, wash
tunnels, and retail areas
|
Group care facility
|
Parking demand analysis
|
Group home
|
1 per 3 beds plus 1 per each employee on peak shift
|
Halfway house/recovery community
|
1 per each employee on the maximum shift and 1 per each employee
on the preceding shift
|
Heliport
|
2 per landing area
|
Hospital
|
Parking demand analysis
|
Junkyard
|
1 per employee on peak shift, plus 1 per 200 square feet of
floor area used for office or administrative functions
|
Kennel
|
1 per each employee on the maximum shift and 1 per each 200
square feet of area devoted to the kennel area
|
Library
|
1 per 300 square feet of floor area
|
Light manufacturing, research, and testing
|
1 per employee on peak shift plus 1 per 300 square feet of office
area
|
Logging or timber harvesting
|
1 per service vehicle
|
Medical clinic
|
1 per 200 square feet of floor area
|
Medical marijuana dispensary
|
1 per 200 square feet of floor area
|
Medical marijuana grower/processor
|
1 per 200 square feet of floor area
|
Methadone treatment facility
|
1 per 200 square feet of floor area
|
Microbrewery/distillery
|
1 per 50 square feet of floor area plus 1 per employee on peak
shift
|
Mineral development
|
1 per employee plus 1 per facility vehicle
|
Mixed use
|
Combined total for the dwelling type plus the nonresidential
use
|
Motel or hotel
|
1 per rentable room plus 1 per employee on peak shift
|
Natural gas compressor station
|
1 per employee
|
Natural gas processing plant
|
1 per employee
|
Nature preserve
|
1 per each acre of land, 5 spaces minimum
|
Nightclub
|
1 per 2 seats
|
Nurserie
|
1 per employee on peak shift plus 5 spaces (minimum)
|
Office, business and professional
|
1 per 300 square feet of floor area
|
Oil and gas development
|
1 per employee plus 1 per facility vehicle
|
Outdoor advertising sign
|
1 per site
|
Park, dedicated open space, or recreational land
|
As determined by the Board of Supervisors, if part of a land
development determined as per parking demand analysis
|
Park-and-ride facility
|
Not applicable
|
Pharmacy
|
1 per 200 square feet of floor area
|
Place of worship
|
1 per 4 seats
|
Recreation facility, commercial or private
|
Determined as per parking demand analysis
|
Recreation facility, public
|
As determined by the Board of Supervisors, if part of a land
development determined as per parking demand analysis
|
Restaurants
|
1 per 50 square feet of floor area plus 1 per employee on peak
shift
|
Restaurants, drive-through
|
1 per 50 square feet of floor area plus vehicle queue area
|
Retail sales and services
|
1 per 200 square feet of floor area
|
School
|
Determined as per parking demand analysis
|
Self-storage facility
|
1 per 100 storage units plus 3 for management staff
|
Short-term rentals
|
2 per dwelling unit
|
Solar energy facilities, large
|
1 per service vehicle
|
Swimming pools, public/commercial, principal
|
Determined as per parking demand analysis
|
Theater, drive-in
|
Determined as per parking demand analysis
|
Theater, indoor
|
12 per 1,000 square feet of floor area
|
Trade school
|
Determined as per parking demand analysis
|
Transit bus stop
|
Not applicable
|
Vehicle dealership, new
|
1 per each 2,000 square feet of lot area for employee and customer
parking (excludes vehicle display area)
|
Vehicle dealership, used
|
1 per each 2,000 square feet of lot area for employee and customer
parking (excludes vehicle display area)
|
Vehicle repair and service station
|
3 per repair bay plus 1 per each employee on peak shift
|
Vehicle salvage yard
|
1 per employee on peak shift, plus 1 per 200 square feet of
floor area used for office or administrative functions
|
Vineyard
|
Determined as per parking demand analysis
|
Warehouses
|
1 per employee on peak shift plus 1 per 300 square feet of office
area
|
Warehouse sales
|
1 per employee on peak shift and 1 plus 200 square feet of sales
area
|
Wind energy facility, large
|
1 per service vehicle
|
Winery
|
Determined as per parking demand analysis
|
WCF
|
1 per service vehicle
|
Uses not listed
|
Determined as per parking demand analysis; parking spot approval
will be determined by the Township Traffic Engineer and Township staff
|
Table 13: Minimum Parking Stall Dimension Requirements
| ||||
---|---|---|---|---|
Type of Parking
|
Angle
|
Stall Length
(feet)
|
Stall Width
(feet)
|
Aisle Width
(feet)
|
Traditional
|
90
|
18
|
9
|
24
|
Traditional
|
60
|
22
|
10
|
20
|
Traditional
|
45
|
20
|
10
|
15
|
ADA
|
90
|
19
|
13
|
24
|
ADA
|
60
|
21
|
13
|
18
|
ADA
|
45
|
19
|
13
|
13
|
Table 14: ADA Parking Space Requirements
| |
---|---|
Total Spaces Provided
|
Required Minimum Number of Accessible Spaces
|
1 to 25
|
1
|
26 to 50
|
2
|
51 to 75
|
3
|
76 to 100
|
4
|
101 to 150
|
5
|
151 to 200
|
6
|
201 to 300
|
7
|
301 to 400
|
8
|
401 to 500
|
9
|
501 to 1,000
|
2% of total
|
More than 1,000
|
20, plus 1 for each 100 spaces over 1,000
|
Table 15: EV Charging Station Requirements
| |
---|---|
Land Use Type
|
% of EV Parking Spaces
|
Garden apartment (guest parking areas)
|
10%
|
Motel or hotel
|
3%
|
Retail
|
1%
|
Restaurant
|
1%
|
Office, business or professional
|
3%
|
Hospital
|
3%
|
Medical clinic
|
3%
|
Light research, manufacturing, testing
|
1%
|
School or trade school
|
3%
|
Place of worship
|
3%
|
All recreational uses (public, private, or commercial)
|
1%
|
Other
|
3%
|
Table 16: Minimum Off-Street Queuing/Stacking Requirements
| ||
---|---|---|
Land Use Type
|
Minimum Stacking Spaces
|
Measured From
|
Car wash, automatic
|
9
|
Entrance
|
Car wash, self-service
|
2
|
Entrance
|
Financial institution, ATM lane
|
3
|
Teller
|
Financial institution, teller lane
|
4
|
Teller or window
|
Gas/fuel station
|
4
|
Pump island
|
Pharmacy
|
4
|
Window
|
Restaurant, drive-through
|
6
|
Order box kiosk
|
Restaurant, drive-through
|
4
|
Order box to pick up window box kiosk
|
Vehicle repair and service station
|
3
|
Per bay service bay
|
Other
|
Determined by Zoning Officer
|
Table 17: Cluster Box Unit (CBU) Parking Requirements
| |
---|---|
Number of Mailboxes per Location
|
Number of Parking Spaces
(Minimum)
|
1 - 25
|
2
|
26 - 50
|
4
|
51 - 80
|
6
|
80 - 110
|
8
|
111+
|
8 + 1 per each additional 25 mailboxes
|
Table 18: Ground Monument Sign Allowable Increases
| ||
---|---|---|
Setback
(feet)
|
Height
(feet)
|
Area
(square feet)
|
15
|
5
|
60
|
18
|
6
|
68
|
21
|
7
|
76
|
24
|
8
|
84
|
27
|
9
|
92
|
30
|
10
|
100
|
Table 19: Freestanding and Pole/Pylon Sign Allowable Increases
| ||
---|---|---|
Setback
(feet)
|
Height
(feet)
|
Area
(square feet)
|
15
|
10
|
30
|
20
|
14
|
40
|
25
|
18
|
50
|
30
|
22
|
60
|