A.
|
In Section PM-100.l (page 1, second line), the
following shall be inserted: "City of Margate City."
| ||
B.
|
In Section PM-109.2 (page 7, third line), the
following amounts shall be inserted: "$25" and then "$1,000."
| ||
C.
|
In Section PM-109.2 (page 7, fourth line), the
following shall be inserted: "30 days."
| ||
D.
|
In Section PM-302.12 (page 17, first line.),
the following dates shall be inserted: "May 15 to October 15."
| ||
E.
|
In Section PM-601.1 (page 27, tenth line), the
following dates shall be inserted: "October 1 to May 1."
| ||
F.
|
In Section PM-601.2 (page 27, second line),
the following dates shall be inserted: "October 1 to May 1."
| ||
G.
|
Section PM-6O2.1.1, Receptacles, is amended
to add as follows:
| ||
(l)
|
Bathroom receptacles shall have ground-fault
circuit-interrupter protection for personnel.
| ||
(2)
|
All one-hundred-twenty-five-volt, single-phase,
fifteen- and twenty-ampere receptacles within six feet of a kitchen
sink to serve kitchen counter top surfaces shall have ground-fault
circuit-interrupter protection for personnel. Exception: receptacles
serving refrigerators and freezers that are not readily accessible.
Readily accessible receptacles serving refrigerators and freezers
shall be a single receptacle.
| ||
(3)
|
At least one twenty-ampere duplex receptacle
shall be installed to serve any kitchen counter top space wider than
12 inches.
| ||
(4)
|
All outdoor, basement and garage receptacles
shall comply with 1990 NEC 210-8.
| ||
H.
|
Section PM-602.l.2, Lighting fixtures, is amended
to add as follows:
| ||
(l)
|
At least one wall-switch-controlled lighting
outlet shall be installed at every outdoor entrance or exit.
| ||
(2)
|
Fixtures in clothes closets shall comply with
1990 NEC 410-8.
| ||
I.
|
Section PM-603.0, Elevators, Escalators and
Dumbwaiters, is hereby deleted.
[Amended 12-10-1992 by Ord. No. 1992-22] | ||
J.
|
Section PM-302.10, Handrails and guardrails,
first sentence, is amended to read as follows:
| ||
PM-302.10, Handrails and guardrails: Every flight of stairs which contains three or more risers shall
have a handrail on at least one side of the stairs, and every open
portion of the stairs, landing or balcony which is more than 30 inches
(762 millimeters) above the floor or grade below shall have guardrails.
| |||
K.
|
Section PM-302.10.1 is added as follows:
| ||
PM-302.10.1 Guards: Guards shall
be designed so as not to allow a six-inch sphere to pass through.
| |||
L.
|
Section PM-403.3, Area for sleeping purposes,
is amended as follows:
| ||
PM-403.3 Area for sleeping purposes: All square footage shall be 70 square feet.
| |||
M.
|
In Section PM-302.12, Insect screens, the following
dates shall be inserted in the first line: "April 1 to October 30."
| ||
N.
|
Section PM-303.9 is hereby added as follows:
| ||
PM-303.9 Guards: Guards shall be
designed so as not to allow a six-inch sphere to pass through.
| |||
O.
|
Section P.M. 607.0, Carbon monoxide detectors,
is added as follows:
[Added 3-13-2003 by Ord. No. 2003-3] | ||
P.M. 607.1 General: All homes rented
or sold within the City of Margate shall be required to have carbon
monoxide detectors, manufactured, listed and labeled in accordance
with UL 2034 and installed in accordance with the requirements of
N.F.P.A. 720.
| |||
P.M. 607.2 Installation: Carbon
monoxide detectors shall be installed in accordance with the manufacturer's
suggested installation instructions.
|