[HISTORY: Adopted by the Board of Health
of the Town of Westminster 8-19-2009, effective 9-1-2009, as amended through 6-15-2011. Subsequent amendments noted where applicable.]
GENERAL REFERENCES
Private and semipublic wells — See Ch.
255.
In accordance with MGL c. 111, § 31, and MGL c. 21A,
§ 13, the Town of Westminster Board of Health ("the Board")
hereby adopts the following local regulations for on-site subsurface
disposal of sewage for the purpose of protecting the public health,
safety, and welfare and for the protection of the environment.
The following regulations constitute an exercise of the power
of home rule as provided in Amendment Article 89 of the Massachusetts
Constitution. As such, they are in addition to the provisions of 310
CMR 15.000, the State Environmental Code Title 5, Standard Requirements
for the Siting, Construction, Inspection, Upgrade, and Expansion of
On-Site Sewage Treatment and Disposal Systems and for the Transport
and Disposal of Septage ("Title 5"). All minimum offsets and other
requirements of Title 5 shall apply unless otherwise hereby indicated
in these regulations. All previous local sewage disposal regulations
indicated in Chapter 245 of the Code of the Town of Westminster shall
be superseded by these regulations.
Any existing requirement of Title 5 not specifically addressed
in these regulations shall be deemed to be incorporated herein by
reference. Should any such Title 5 regulation be amended, supplemented
or modified after the adoption of these regulations so as to render
it less stringent than at the time of the adoption of these regulations,
such amendment, supplement or modification shall not apply hereunder
until and unless the Board votes to adopt such amendment, supplement
or modification.
The following words as used in these regulations shall have
the following meanings, unless a different meaning is required by
the context, or as specifically provided:
AGENT
Any person authorized by the Board to act pursuant to MGL
c. 111, § 30, 310 CMR 15.000 and these regulations.
BOARD OF HEALTH
The Board constituted in accordance with MGL c. 41, § 1
and/or § 1B .
CESSPOOL
A pit with open-jointed linings or holes in the bottom and/or
sidewalls into which raw sewage is discharged, the liquid portion
of the sewage being disposed of by seeping or leaching into the surrounding
soils, and the solids or sludge being retained in the pit.
EXPANSION OF USE
A change that would result in the increased utilization of
the current septic system. Examples include, but are not limited to,
increased flows, installation of a large whirlpool tub in a bathroom,
any change that may have an effect on how the system is functioning.
LOT
A single parcel of land undivided by a street under one ownership
with ascertainable boundaries established by a deed of record.
SHARED OR COMMON SEPTIC SYSTEM
Any privately owned on-site wastewater system that serves
more than one lot or more than one principal building or systems with
a designed flow greater than 2,500 gallons per day.
SOIL ABSORPTION SYSTEM PERIMETER
The area defined by the outer edge of the leaching bed/field
or the outer edge of the leaching trenches of a soil absorption system.
This is the same area as is used in Title 5 to calculate the minimum
area for the design of a soil absorption system.
A. All permits granted by the Board must be in writing and signed by
a representative of the Board.
B. No work shall be commenced prior to having a signed permit in hand.
In the Town of Westminster, all leaching areas shall be 125%
of Title 5 design criteria.
A passing official Title 5 inspection shall be required upon
an increase in habitable space requiring a building permit from the
local building inspector, where the estimated cost of such equals
or exceeds 30% of the assessed value of the structure at the time
of the application. A Title 5 inspection may be waived by the agent
where the landowner produces a valid certificate of compliance issued
not more than 10 years prior thereto or a valid Title 5 inspection
report issued not more than five years prior thereto. In either case,
no such waiver shall be issued unless the landowner also produces
records acceptable to the agent showing that the system had been pumped
at least every three years since the issuance of the certificate or
the Title 5 inspection, as applicable.
A. No septic system shall be located in whole or in part on a lot other
than the lot upon which the facility to be served is located or to
be located. No septic system fill shall be placed or located on a
lot other than the lot upon which the facility to be served is located.
These prohibitions shall not apply to the repair or replacement of
a system lawfully in place at the time of the effective date of these
regulations.
B. The use of a retaining wall in the design of a septic system is hereby
prohibited. The Board may issue a variance from this prohibition where
the applicant can prove to the Board's satisfaction that the retaining
wall can be maintained and/or be rebuilt if necessary from the applicant's
lot without affecting or encroaching on abutting property. The Board
may, as a condition of such a variance, require security for the repair
or rebuilding of the retaining wall. A survey may be required to delineate
the property line.
A Title 5 inspection, including a passing Title 5 inspection
report, shall not be interpreted as establishing that the system is
or will function properly, and the Board reserves the right to undertake
such enforcement action as it deems appropriate with regard to an
improperly functioning system notwithstanding such a passing Title
5 report.
[Amended 11-16-2021 STM by Art. 4]
In accordance with MGL c. 44, § 53G, the Board may
require an applicant for a subsurface disposal system to deposit funds
for the employment of outside consultants. The applicant shall have
the right to an administrative appeal from the selection of the outside
consultant to the Select Board. The grounds for such an appeal shall
be limited to claims that the consultant selected has a conflict of
interest or does not possess the minimum, required qualifications.
The minimum qualifications shall consist either of an educational
degree in or related to the field at issue or three or more years
of practice in the field at issue or a related field.
Shared and/or common subsurface disposal systems are hereby
prohibited. Any sewage disposal system must be located on the same
lot as the dwelling or facility it serves. The Board may issue a variance
from this prohibition of shared or common systems where an existing
system has failed or is otherwise in need of repair or replacement,
and due to soil or lot conditions it is not feasible to replace the
system with an individual system. The landowner shall have the burden
of establishing that an individual system is not feasible. The Board
may also grant a hardship variance for any shared and/or common systems
approved between September 21, 2005, and July 1, 2009, but not built.
Any shared and/or common system approved by variance or any system
that becomes a shared and/or common system by virtue of a conversion
of the property to condominium ownership, shall be subject to a financial
security agreement providing for the ongoing repair, upgrade and replacement
of the system in a form and on terms acceptable to the Board.
Percolation tests and deep hole observation tests shall expire
two years after the date of completion. Written requests for extensions
may be allowed on a site-specific basis, provided that the location
of the percolation test and deep hole observation tests can be located
from known and recoverable reference points or benchmarks so that
it may be located on the system design plan within one foot, and that
there have been no alterations of the area, adjacent areas, or other
changes that may have compromised the validity of the tests.
Percolation and soil testing shall be allowed to be conducted
year round. On lots where it is difficult to determine the estimated
seasonal high-water table by soil mottling, the Board may require
a groundwater-monitoring well to be installed on the lot for confirmation
of the estimated seasonal high-water table. The type, design, time
duration and other specifics of the monitoring wells will be left
to the discretion of the Agent and/or the Board. No leaching area
primary or reserve shall be sited within 25 feet from an abandoned
or unsuitable deep observation hole or unsuitable percolation test.
When the system design includes the reserve between the primary trenches,
there need to be two acceptable percolation tests within 10 feet of
the soil absorption system perimeter, with one being within the perimeter.
When the system design includes the reserve being separate from the
primary system, there needs to be one acceptable percolation test
within the soil absorption system perimeter and one within the designated
area for the reserve. When the percolation tests are not consistent,
the agent will require additional testing in order to assure proper
sizing of the system.
A. All piping, including the perforated leaching area pipe, shall be
a minimum Schedule 40.
B. Except when indicated otherwise by Title 5, every septic tank shall
be equipped with an effluent outlet tee filter approved by the Department
of Environmental Protection.
C. Access ports for gaining access to the D-box and tanks must be within
six inches of final grade.
D. All distribution boxes installed shall be H-20 load rated.
E. All systems utilizing pump chambers shall have a system operation
manual posted in immediate proximity to the alarm panel so the homeowner
can access it.
F. A septic plan shall contain a provision for pumping the tank if the
vertical distance between the bottom of the septic tank and the elevation
where the pumping truck is located is greater than 28 feet.
G. All septic plans shall contain a change/revisions log. No changes
from the original submitted plan will be deemed approved unless each
change has been initialed by the approving authority.
H. Inspections.
(1) All subsurface sewage disposal systems shall have the following minimum
inspections as required by the Board.
(a)
Initial inspection prior to filling the leaching area with fill
(bottom of the bed/trench).
(b)
Completed system prior to backfilling.
(c)
Final grading inspection.
(2) The agent may require additional inspections at his/her discretion.
I. The designer's as-built plan shall be prepared in accordance with
Title 5's requirements, include final grading elevations, and submitted
in triplicate. The as-built shall also be submitted on compact disc
in PDF format.
J. The installer's as-built plan shall be prepared on a form provided
by the Westminster Board of Health.
K. Prior to the issuance of a certificate of compliance by the Board
of Health, the applicant or the system installer shall provide the
designer's as-built drawing in a form specified by the Board as a
permanent document (laminated) at a location in the dwelling near
the building sewer exit location or electrical service entry, which
shows location on the lot of the septic tank, distribution box, leaching
area, and well where applicable.
L. No construction shall begin on a septic system until the Building
Department grants a building permit.
M. No certificate of compliance will be issued until such time as the
building is complete enough to ascertain the number of bedrooms and
bathrooms.
A. The Westminster Board of Health reserves the right to modify the
regulations and treat each system in drinking water and/or watershed
protection areas in the Town separately to assure the health and general
welfare of individuals using this resource.
B. Anyone planning on siting a system in these areas must contact the
Health Agent prior to expending any resources to find out if additional
requirements may be required.
Every subsurface disposal system septic tank shall be pumped
when the sludge exceeds 1/4 of the tank's depth or once every three
years, whichever occurs sooner. For multifamily dwellings, including
condominiums, apartments, motels, hotels and boardinghouses, the septic
tank shall be pumped at least once every year. The owner of any such
multifamily dwelling shall provide to the Board written proof of such
annual pumping, by paid invoice or other suitable documentation from
a septage handler who has a valid Massachusetts permit, on or before
February 1 of each year, for the preceding calendar year.
No new sewage disposal system shall be installed within 100
feet of any watercourse, stream, brook, river, pond or wetlands. For
any system, the distances required by Title 5 and these regulations
are minimum distances which may be increased if, in the opinion of
the agent, such an increase is required to protect the environment
or the public health. The Board may grant a hardship variance for
lots purchased or created between September 21, 2005, and July 1,
2009, in reliance on the prior regulation where the system could have
been located 50 feet from such watercourse, stream, brook, river,
pond or wetland, but cannot be located more than 100 feet therefrom.
The applicant shall install the subsurface disposal system in
strict conformity with the approved plan. Minor deviations from the
approved plan may be permitted by the agent where the designer submits,
in writing, a statement setting forth the deviation and affirming
that the deviation does not affect the plan's compliance with these
regulations. All such deviations shall be shown on the as-built plans.
The following events will require the applicant to file with
the Registry of Deeds a recording acceptable to the Board prior to
granting a construction permit or a certificate of compliance as specified
in Title 5. Reference in Title 5:
A. Smaller number of bedrooms than presumed by Title 5: 15.002, Bedroom.
B. Open space created in a cluster development: 15.002, Cluster Development.
C. A home with flow of less than 330 gallons per day: 15.203.
D. The number of bedrooms in a condominium: 15.203.
E. Installation of a tight tank: 15.260(6).
F. Installation of an alternative technology: 15.287(10).
G. Installation of a shared system: 15.290(2)(e).
H. For large systems, demonstration of an equal level of environmental
protection: 15.304(3)(b)6.
I. A variance issued for which a deed restriction is required: Title
5 15.413(1).
J. Facility aggregation plans: 15.216(5)(a)2.
All installers of subsurface disposal systems shall have a copy
of the stamped approved plan in their possession on the site while
installing the system, which shall be available to the agent at the
time of any inspection.
Where an existing unoccupied, dilapidated structure is proposed
for redevelopment, rehabilitated, renovated, reconstructed, or remodeled,
the septic system must have been designed and installed in compliance
with the then-current Title 5 regulations, and the owner shall provide
a current "passed" Title 5 inspection.
The Board reserves the right to revoke any approval, permit
or certificate of compliance which is found to be based on incorrect,
incomplete or misleading information.
All Title 5 inspections must be witnessed by the agent unless
a waiver is granted. All items included in a Title 5 onspection report
must be personally witnessed by the inspector, including but not limited
to the number of bedrooms, laundry facilities, water filtration systems,
and the presence of a garbage grinder. The report shall specifically
identify the source of the information in the report. Example: "Plan
located at Board of Health dated 5/16/2005," or "septic plan from
homeowner dated 5/16/2007." The agent must be notified at least 72
hours in advance of any proposed inspection.
A. All seepage pits must be located and inspected.
B. All cesspools systems shall constitute an automatic failure.
C. The Board or its agent may request a soil evaluation by a state-certified
soil evaluator for any Title 5 inspection.
D. Private wells must be tested as Part of the Title 5 inspection done
for transfer of property.
E. Groundwater determination may be accomplished with the concurrence
of the agent in the following ways:
(1) Perc test/soil evaluation data done after October 1995.
(2) Soil evaluation from nearby lot.
(3) Observe below the deepest component to show it is not sitting in
groundwater.
(4) The location/elevation of the system in proximity to a body of water
or wetland.
(5) Other evidence of water table levels, i.e., sump pump, shallow well,
lake level, etc.
(6) Other methods listed in Title 5 inspector training book.
F. Repairs to sanitary tees and the installation of risers do not need
a disposal works construction permit from the Board. All other repairs
will need a permit and require a licensed installer.
All plans approved and construction permits granted shall lapse
three years from the date of endorsement or issuance unless a certificate
of compliance is issued therefor. If a plan or permit lapses, the
applicant shall file a new application and meet the then-current regulations.
The Board may issue one extension, for a period of no more than one
year, provided that the application for such extension is filed prior
to the lapse of the permit.
A. Systems requiring power and/or alarms need a wiring permit and must
meet all applicable requirements.
B. Additional requirements:
(1) All pumps need to be hard-wired; no plugs.
(2) No plugs in pump chamber.
(3) All alarms need to be hard-wired and on their own circuit.
A fine of $50 per day will be imposed on anyone who knowingly
violates the state's and/or the Town's Sanitary Code.