Required
| |
---|---|
Total Parking Spaces
|
Accessible Spaces
|
1 to 25
|
1
|
26 to 50
|
2
|
51 to 75
|
3
|
76 to 100
|
4
|
101 to 150
|
5
|
151 to 200
|
6
|
201 to 300
|
7
|
301 to 400
|
8
|
401 to 500
|
9
|
501 to 1,000
|
2% of the total number of spaces
|
Over 1,000
|
20, plus 1 additional space per each 100 spaces over 1,000
|
Uses
|
Required Parking Spaces
(gross floor area)
| ||
---|---|---|---|
Banks/financial institutions
|
1 per 300 square feet gross floor area ("GFA")
| ||
Bowling centers
|
5 for each bowling lane, in addition to requirements for eating
establishments on site
| ||
Conference center
|
1 per sleeping room or suite, plus 1 per every 2 employees on
the largest work shift, plus 1 per 2 persons to the maximum capacity
of each public meeting and/or banquet room, plus 50% of the spaces
otherwise required for accessory uses (i.e., restaurants and bars)
| ||
Convenience stores
|
1 per 150 square feet GFA
| ||
Campground
|
1 10-foot-by-30-foot space per campsite
| ||
Swimming pools, roller/ice rinks, and other similar uses
|
1 per 100 square feet GFA of recreational surface, plus one
for each 30 square feet of GFA used for spectator seating purposes,
as applicable
| ||
Day-care facilities
|
1 per employee, plus 1 safe passenger off-street loading/unloading
space per 5 children
| ||
Eating establishments
|
1 per 2 seats
| ||
Fast-food establishments
|
1 per 30 square feet GFA
| ||
Family care and group care facilities
|
1 per 4 residents, plus 1 per employee in the maximum working
shift
| ||
Family day-care and group day-care facilities
|
1 per nonresident employee, plus 1 safe passenger off-street
loading/unloading space per 4 nonresident children
| ||
Funeral homes/mortuaries
|
1 per 100 square feet GFA used for memorial services, viewing
area, business office and products display
| ||
Furniture, carpet or appliance store
|
1 per 500 square feet GFA
| ||
Gasoline service station
|
1 per 3 gasoline pumps in addition to fueling and pump stacking
area
| ||
Golf course
|
4 per tee, plus 1 per employee
| ||
Golf course (miniature)
|
2.5 per hole plus 1 per employee
| ||
Golf driving range
|
1.5 per tee, plus 1 per employee
| ||
Health or exercise facility
|
1 per 100 square feet of GFA
| ||
Home occupations
|
1 per nonresident employee, in addition to the requirement for
the dwelling unit; plus requirements determined by the Zoning Hearing
Board in granting the special exception
| ||
Hospitals and medical facilities
|
1 per 4 beds, plus 1 per 2 employees of the maximum working
shift, plus one per staff doctor
| ||
Outpatient medical centers
|
2 per patient room, plus 1 per employee of the maximum working
shift
| ||
Hotels, motels, boardinghomes and lodging/rooming houses, bed-and-breakfast
establishments (excluding conference centers)
|
1 per sleeping room, plus 1 per 200 square feet GFA of public
meeting area, plus 1 per every 2 employees on the largest work shift
| ||
Industrial uses
|
1 per 800 square feet of GFA
| ||
Junkyard
|
1 per employee, plus 1 per 5,000 square feet of lot area, excluding
required buffer area
| ||
Laboratories, research and development
|
3.5 per 1,000 square feet of GFA
| ||
Laundries, self-serve
|
1 per washing machines
| ||
Building supply establishment
|
1 per 500 square feet GFA, plus 1 per 1,000 square feet of indoor/outdoor
storage area
| ||
Medical offices
|
1 per 250 square feet GFA
| ||
Nursery/greenhouse
|
1 per 1,000 square feet GFA, plus 1 per 2,000 square feet lot
area, excluding buffer area
| ||
Nursing/personal health care facilities
|
1 per 3 beds, plus 1 per 2 employees in the maximum working
shift, plus 1 per staff doctor
| ||
Office
| |||
50,000 square feet GFA or less
|
1 per 200 square feet GFA
| ||
50,001 to 100,000 square feet GFA
|
1 per 225 square feet GFA
| ||
100,001+ square feet GFA
|
1 per 250 square feet GFA
| ||
Places of public or private assembly (churches, community centers,
theaters or similar meeting and assembly uses)
|
1 per 3 seats or 1 per 100 square feet GFA where no seats are
provided
| ||
Residential uses
| |||
Single-family dwellings
|
2 per dwelling unit
| ||
Multifamily dwellings (including conversion apartments
and excluding accessory apartments)
|
[NOTE: The total number of required off-street parking spaces
for a multifamily dwelling building shall not be less than two spaces
per dwelling unit]
| ||
Age-restricted dwellings
|
0.5 per dwelling unit
| ||
Efficiency/studio
|
1 per dwelling unit
| ||
1 bedroom
|
1 per dwelling unit
| ||
2 bedrooms
|
2 per dwelling unit
| ||
3 bedrooms or more
|
3 per dwelling unit
| ||
Visitor parking
|
0.2 per dwelling unit
| ||
Staff parking
|
1 per employee on maximum shift
| ||
Retail sales establishments
| |||
50,000 square feet GFA or less
|
1 per 200 square feet GFA
| ||
50,001 to 100,000 square feet GFA
|
1 per 250 square feet GFA
| ||
100,001 to 400,000 square feet GFA
|
1 per 300 square feet GFA
| ||
400,001+ square feet GFA
|
1 per 350 square feet GFA
| ||
Retail sales, outdoor
|
1 per 500 square feet of open sales/display area, plus 1 per
employee during maximum shift
| ||
Produce stands
|
1 per 200 square feet of sales area
| ||
Storage facility
| |||
Individual mini storage
|
1 per 10 units, plus 1 per 200 square feet of office area, plus
2 per resident manager
| ||
Commercial
|
2 per unit
| ||
Schools
| |||
Elementary
|
2 per classroom, but not less than 1 per teacher and staff member
| ||
Intermediate
|
1.5 per classroom, but not less than 1 per teacher and staff
member
| ||
Secondary
|
1 per teacher and staff member and 1 per four students, based
on design capacity
| ||
Stadiums, auditoriums, gymnasiums and similar places
of assembly
|
Additional spaces in accordance with places of assembly requirements
| ||
Shopping centers (regional)
| |||
Under 400,000 square feet GFA
|
1 per 250 square feet GFA
| ||
400,000 to 500,999 square feet GFA
|
1 per 300 square feet GFA
| ||
600,000+ square feet GFA
|
1 per 350 square feet GFA
| ||
Shopping centers (neighborhood)
|
1 per 250 square feet GFA for the first 1,000 square feet, plus
5 for each additional 1,000 square feet GFA, plus additional spaces,
as required herein, for associated offices, theaters and eating establishments
| ||
Taverns, clubs, lodges and similar uses
|
1 per bar seat, plus 1 per 20 square feet GFA of bar area, plus
1 per employee on maximum shift, plus public assembly requirements
for meeting space
| ||
Utility facilities
|
1 per vehicle normally required to service such facility
| ||
Vehicular parts sales/service garages sales area
|
3 per bay, plus 1 for every 200 square feet of retail parts
| ||
Vehicular sales or rental establishment
|
1 per 500 square feet of indoor GFA, plus 1 per 2,500 square
feet of outdoor sales/rental area, plus 2 per service bay, plus 1
per employee, but never fewer than five total spaces
| ||
Vehicular wash
|
2 per washing lane, in addition to stacking lanes
| ||
Veterinary facility
|
4 per doctor or allied professional trained person occupying
the use, plus 1 per every additional employee
| ||
Warehouse or distribution center
| |||
Under 50,000 square feet GFA
|
1 per 5,000 square feet GFA, plus required spaces for any office
or sales areas
| ||
50,001 square feet and over GFA
|
1 per 10,000 square feet GFA, plus required spaces for any office
or sales areas
|
Use
|
Required Stacking Area
|
---|---|
Car wash, automatic
|
4 vehicle lengths per bay at entrance; 2 vehicle lengths per
bay at exit
|
Car wash, self-service
|
4 vehicle lengths per bay at entrance; 1 vehicle length per
bay at exit
|
Fast-food eating establishment
|
6 vehicle lengths behind menu board; 4 vehicle lengths behind
first window
|
Financial establishment
|
4 vehicle lengths per lane, drive-up teller, kiosk or ATM
|
Gated parking lot entrance
|
1 vehicle length per gate
|
Gated unit or overhead door
|
1 vehicle length per door
|
Retail service, such as photo processing, dry cleaner, pharmacy,
coffee-to-go, etc.
|
2 vehicle lengths per window
|
Vehicular fueling pumps
|
2 vehicle lengths per pump
|
Angle of Parking
|
Parking Space Width
(feet)
|
Depth*
(feet)
|
Aisle Width One-Way
(feet)
|
Two-Way
(feet)
|
---|---|---|---|---|
90°
|
9
|
18
|
24
|
24
|
60°
|
9
|
20
|
18
|
20
|
45°
|
9
|
18
|
15
|
20
|
30°
|
9
|
16
|
12
|
20
|
Parallel
|
8
|
22
|
12
|
20
|
NOTES:
|
---|
* Space depth is the perpendicular measurement from the curb
or edge of the parking lot toward the interior portion of the lot
to be occupied by the parking vehicles and not including any part
of the drive.
|
Gross Floor Area
(square feet)
|
Required Number of Loading/Unloading Spaces
|
---|---|
6,000 or less
|
1
|
6,001 to 20,000
|
2
|
Above 20,000
|
2, plus 1 additional space for each additional 50,000 square
feet of gross floor area
|
Function
|
Required Cartway Width
(feet)
|
---|---|
2 lanes of traffic with on-street parking
|
36
|
2 lanes of traffic without on-street parking
|
24
|
1 lane of traffic with 1 lane of on-street parking
|
20
|
1 lane of traffic without on-street parking
|
12
|
NOTES:
| |
---|---|
1
|
Access drives that serve less than four residential units may
have a cartway width of 18 feet.
|
2
|
Off-street parking lots must be provided in accordance with
this chapter.
|
3
|
The one-way direction of traffic must be identified along the
cartway.
|