[R.O. 1992 § 405.290; CC 1984 § 43.500; Ord. No. 2269-08 § 1, 8-19-2008]
In order to protect the health, safety and general welfare of
the people, the Planning and Zoning Commission will reject any proposed
subdivision located in an area subject to periodic flooding. Whenever
a subdivision is proposed to be located in an area having poor drainage
or other adverse physical characteristics and impairment, the Planning
and Zoning Commission may approve the plat, provided the developer
binds himself/herself legally to make such improvements as, in the
judgment of the Planning and Zoning Commission, will render the subdivision
substantially safe and otherwise acceptable for the intended use.
[R.O. 1992 § 405.295; Ord. No.
2269-08 § 1, 8-19-2008]
All design elements submitted for consideration for the development
of subdivisions within the City limits of Camdenton shall be prepared
by a professional engineer licensed by the State of Missouri, including
streets, storm drainage (construction and permanent), street lighting
and water and sewer systems. These drawings and/or prints shall bear
the seal and signature of the professional engineer who has design
jurisdiction.
[R.O. 1992 § 405.300; CC 1984 § 43.510; Ord. No. 2269-08 § 1, 8-19-2008]
The subdivision layout shall conform to the official Comprehensive
Plan. Unless otherwise approved by the Board of Aldermen provision
must be made for the extension of main thoroughfares as designated
by the Planning and Zoning Commission, and other major or collector
streets must provide free circulation with the subdivision.
[R.O. 1992 § 405.310; CC 1984 § 43.520; Ord. No. 2269-08 § 1, 8-19-2008]
A. The system of streets designated for the subdivision shall connect
with streets already dedicated in adjacent subdivisions; and where
no adjacent connections are platted shall in general be the reasonable
projections of streets in nearest subdivided tracts, and shall be
continued to the boundaries of the tract subdivided, so that other
subdivisions may connect therewith.
1.
New street systems shall be designed to allow future continuation
of streets through adjoining properties and subdivisions whenever
possible.
2.
Cul-de-sac streets shall be limited in use and allowed only
when no other options are available.
3.
All new subdivisions shall be designed to allow access by platted streets that are accessed from existing City streets or from platted streets from subdivisions that have been approved per Article
III, Article
IV and Article
V of this Chapter.
a.
Subdivisions shall not be accessed by roadway easements.
b.
Subdivisions shall not be accessed by private driveways.
c.
Subdivisions shall not be accessed only from fire apparatus
access roads (fire lanes).
[R.O. 1992 § 405.320; CC 1984 § 43.530; Ord. No. 2269-08 § 1, 8-19-2008]
A. The following shall be the minimum street right-of-way requirements
and utility easements:
1.
Highways And Major Thoroughfares. Highways and major thoroughfares
as specified in the official thoroughfare plan, not less than seventy-two
(72) feet in any case.
2.
Collector Streets. Sixty (60) feet.
3.
Local Streets. Fifty (50) feet.
4.
Minor Streets, Dead-End Streets And Cul-De-Sac Streets. Cul-de-sac
streets shall be limited to five hundred (500) feet in length. All
dead-end streets shall terminate in a circular turn-around having
a minimum right-of-way diameter of one hundred (100) feet.
5.
Alleys. Alleys, where platted, shall have a minimum width of
twenty (20) feet.
6.
Utility Easements. Utility easements, where required, shall
be at least fifteen (15) feet wide along rear or side lot lines. Easements
of adequate width shall be provided for open drainage channels, where
required.
a.
A ten-foot horizontal separation shall be maintained between
parallel runs of water and sewer lines.
b.
A five-foot horizontal separation shall be maintained between
City regulated utilities and all other utilities.
c.
All underground electric utilities shall be thirty-six (36)
inches below finished grade and all communications utilities shall
be twenty-four (24) inches below finished grade.
[R.O. 1992 § 405.330; CC 1984 § 43.540; Ord. No. 2269-08 § 1, 8-19-2008]
A. Minimum pavement widths, required to be installed at subdivision
expense, shall be as follows:
1.
Major Thoroughfares And Collector Streets. Twenty (20) feet.
In the case of a major thoroughfare or collector street requiring
pavements wider than twenty (20) feet, the matter of financial and
other arrangements for installing such wider pavements at the time
the developer will make the improvements shall be taken up by the
developer with the officials having jurisdiction.
2.
Minor, Local, Dead-End And Cul-De-Sac Streets. Twenty (20) feet.
The pavement of a turning circle at the end of a dead-end street shall
have a minimum outside diameter of eighty (80) feet.
3.
Alleys And Service Drives. Eighteen (18) feet.
4.
Sidewalks. Installed sidewalks shall conform to the currently
adopted ICC/ANSI A117.1 standard and the current edition of the Americans
with Disabilities Act Accessibility Guidelines.
[R.O. 1992 § 405.340; CC 1984 § 43.550; Ord. No. 2269-08 § 1, 8-19-2008]
A. The grades of streets shall not exceed the following, except that
where unusual or exceptional conditions exist, the Planning and Zoning
Commission may modify these requirements.
1.
Highways And Major Thoroughfares. Four percent (4.0%).
2.
Collector Streets. Ten percent (10%).
3.
Minor And Local Streets, Service Drives And Alleys. Twelve percent
(12%).
4.
Pedestrianways And Crosswalks. Twelve percent (12%), unless
steps of an acceptable design are to be constructed.
5.
Minimum Grade. In no event shall the minimum grade of any street
or alley be less than four-tenth of one percent (0.4%).
6.
Radii Of Curvature. The radii of curvature on the center line
shall not be less than four hundred (400) feet for major thoroughfares
and one hundred (100) feet for collector and minor streets.
[R.O. 1992 § 405.350; CC 1984 § 43.560; Ord. No. 2269-08 § 1, 8-19-2008]
A. The size, shape and orientation of lots shall be appropriate for
the location and physical character of the proposed subdivision and
for the type of development contemplated in compliance with the applicable
Zoning Ordinance or Regulations.
1.
Street Access. Every lot shall abut on a street, subject to the requirements of Section
405.310.
2.
Width. Lots for residential purposes shall have sufficient width
at the building set-back lines to permit compliance with side yard
or distance requirements of the applicable Zoning Ordinance or Regulations
and still be adequate for a building of practicable width.
3.
Double-Frontage. Except as otherwise provided herein, double-frontage
lots and reversed-frontage lots shall be avoided.
4.
Side Lot Lines. Where practicable, side lot lines shall be approximately
at right angles to the right-of-way line of the street on which the
lot faces.
5.
Corner Lots. Corner lots for residential use shall be platted
wider than interior lots to permit compliance with the yard and setback
requirements for the applicable Zoning Ordinance.
6.
Minimum Lot Size. Where not otherwise determined by applicable
Zoning Ordinance or Regulations, the minimum lot size for residential
purposes shall be nine thousand (9,000) square feet with a minimum
frontage of seventy-five (75) feet.