The following standards apply to new development, including new and substantially improved structures, in the areas of special flood hazard shown on the Flood Insurance Rate Map designated in §
85-6, Basis for establishing areas of special flood hazard.
A. Subdivision proposals. The following standards apply
to all new subdivision proposals and other proposed development in
areas of special flood hazard (including proposals for manufactured
home and recreational vehicle parks and subdivisions):
(1) Proposals shall be consistent with the need to minimize
flood damage.
(2) Public utilities and facilities such as sewer, gas,
electrical and water systems shall be located and constructed so as
to minimize flood damage.
(3) Adequate drainage shall be provided to reduce exposure
to flood damage.
B. Encroachments.
(1) Within Zones A1-A30 and AE, on streams without a regulatory
floodway, no new construction, substantial improvements or other development
(including fill) shall be permitted unless:
(a)
The applicant demonstrates that the cumulative
effect of the proposed development, when combined with all other existing
and anticipated development, will not increase the water surface elevation
of the base flood more than one foot at any location; or
(b)
The Village of Victor agrees to apply to the
Federal Emergency Management Agency (FEMA) for a conditional FIRM
revision, FEMA approval is received and the applicant provides all
necessary data, analyses and mapping and reimburses the Village of
Victor for all fees and other costs in relation to the application.
The applicant must also provide all data, analyses and mapping and
reimburse the Village of Victor for all costs related to the final
map revision.
(2) On streams with a regulatory floodway, as shown on the Flood Boundary and Floodway Map or the Flood Insurance Rate Map adopted in §
85-6, Basis for establishing areas of special flood hazard, no new construction, substantial improvements or other development in the floodway (including fill) shall be permitted unless:
(a)
A technical evaluation by a licensed professional
engineer shows that such an encroachment shall not result in any increase
in flood levels during occurrence of the base flood; or
(b)
The Village of Victor agrees to apply to the
Federal Emergency Management Agency (FEMA) for a conditional FIRM
and floodway revision, FEMA approval is received and the applicant
provides all necessary data, analyses and mapping and reimburses the
Village of Victor for all fees and other costs in relation to the
application. The applicant must also provide all data, analyses and
mapping and reimburse the Village of Victor for all costs related
to the final map revisions.
[Amended 4-19-2004 by L.L. No. 6-2004]
A. Elevation. The following standards, in addition to the standards in §
85-14A, Subdivision proposals, and §
85-14B, Encroachments, and §
85-15, Standards for all structures, apply to structures located in areas of special flood hazard as indicated.
(1) Within Zones A1-A30, AE and AH, and also Zone A if
base flood elevation data are available, new construction and substantial
improvements shall have the lowest floor (including basement) elevated
to or above one foot above the base flood level.
(2) Within Zone A, when no base flood elevation data are
available, new and substantially improved structures shall have the
lowest floor (including basement) elevated at least three feet above
the highest adjacent grade.
(3) Within Zone AO, new and substantially improved structures shall have the lowest floor (including basement) elevated above the highest adjacent grade at least as high as one foot more than the depth number, specified in feet on the community's Flood Insurance Rate Map, enumerated in §
85-6 (at least two feet if no depth number is specified).
(4) Within Zones AH and AO, adequate drainage paths are
required to guide floodwaters around and away from proposed structures
on slopes.
[Amended 4-19-2004 by L.L. No. 6-2004]
The following standards apply to new and substantially improved commercial, industrial and other nonresidential structures, in addition to the requirements in §
85-14A, Subdivision proposals, and §
85-14B, Encroachments, and §
85-15, Standards for all structures.
A. Within Zones A1-A30, AE and AH, and also Zone A if
base flood elevation data are available, new construction and substantial
improvements of any nonresidential structure, together with attendant
utility and sanitary facilities, shall either:
(1) Have the lowest floor, including basement or cellar,
elevated to or above one foot above the base flood elevation; or
(2) Be floodproofed so that the structure is watertight
below one foot above the base flood level with walls substantially
impermeable to the passage of water. All structural components located
below the base flood level must be capable of resisting hydrostatic
and hydrodynamic loads and the effects of buoyancy.
B. Within Zone AO, new construction and substantial improvements
of nonresidential structures shall:
(1) Have the lowest floor (including basement) elevated
above the highest adjacent grade at least as high as one foot more
than the depth number specified in feet on the community's FIRM (at
least two feet if no depth number is specified); or
(2) Together with attendant utility and sanitary facilities, be completely floodproofed to that level to meet the floodproofing standard specified in §
85-17A(2).
C. If the structure is to be floodproofed, a licensed professional engineer or architect shall develop and/or review structural design, specifications, and plans for construction. A floodproofing certificate or other certification shall be provided to the Local Administrator that certifies the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions of §
85-17A(2), including the specific elevation (in relation to mean seal level) to which the structure is to be floodproofed.
D. Within Zones AH and AO, adequate drainage paths are
required to guide floodwaters around and away from proposed structures
on slopes.
E. Within Zone A, when no base flood elevation data are
available, the lowest floor (including basement) shall be elevated
at least three feet above the highest adjacent grade.
[Amended 4-19-2004 by L.L. No. 6-2004]
The following standards, in addition to the standards in §
85-14, General standards, and §
85-15, Standards for all structures, apply, as indicated, in areas of special flood hazard to manufactured homes and to recreational vehicles which are located in areas of special flood hazard.
A. Recreational vehicles.
(1) Recreational vehicles placed on sites within Zones
A1-A30, AE and AH shall either:
(a)
Be on site fewer than 180 consecutive days;
(b)
Be fully licensed and ready for highway use;
or
(c)
Meet the requirements for manufactured homes in §
85-18B,
D and
E.
(2) A recreational vehicle is ready for highway use if
it is on its wheels or jacking system, is attached to the site only
by quick-disconnect-type utilities and security devices and has no
permanently attached additions.
B. A manufactured home that is placed or substantially
improved in Zones A1-A30, AE and AH that is on a site either outside
of an existing manufactured home park or subdivision as herein defined;
in a new manufactured home park or subdivision as herein defined;
in an expansion to an existing manufactured home park or subdivision
as herein defined; or in an existing manufactured home park or subdivision
as herein defined on which a manufactured home has incurred substantial
damage as the result of a flood, shall be elevated on a permanent
foundation such that the lowest floor is elevated to or above one
foot above the base flood elevation and is securely anchored to an
adequately anchored foundation system to resist flotation, collapse
and lateral movement. Elevation on piers consisting of dry stacked
blocks is prohibited. Methods of anchoring may include, but are not
limited to, use of over-the-top or frame ties to ground anchors.
C. A manufactured home to be placed or substantially
improved in Zone A1-A30, AE and AH in an existing manufactured home
park or subdivision that is not to be placed on a site on which a
manufactured home has incurred substantial damage shall be:
(1) Elevated in a manner such as required in §
85-18B; or
(2) Elevated such that the manufactured home chassis is
supported by reinforced piers or other foundation elements of at least
equivalent strength that are no less than 36 inches in height above
the lowest adjacent grade and are securely anchored to an adequately
anchored foundation system to resist flotation, collapse or lateral
movement. Elevation on piers consisting of dry stacked blocks is prohibited.
D. Within Zone A, when no base flood elevation data are
available, new and substantially improved manufactured homes shall
be elevated such that the manufactured home chassis is supported by
reinforced piers or other foundation elements of at least equivalent
strength that are no less than 36 inches in height above the lowest
adjacent grade and are securely anchored to an adequately anchored
foundation system to resist flotation, collapse or lateral movement.
Elevation on piers consisting of dry stacked blocks is prohibited.
E. Within Zone AO, the floor shall be elevated above the highest adjacent grade at least as high as one foot more than the depth number specified on the Flood Insurance Rate Map enumerated in §
85-6 (at least two feet if no depth number is specified). Elevation on piers consisting of dry stacked blocks is prohibited.