Angle of Parking
(degrees)
|
Parking Space Size
(feet)
|
Drive Aisle Width One-Way
(feet)
|
Two-Way
(feet)
|
---|---|---|---|
65
|
9 by 21
|
18
|
20
|
45
|
9 by 19
|
14
|
18
|
Use in SPD
|
Number of Parking Stalls Required
|
---|---|
Hotel
|
1 for each hotel room designed primarily for the purpose of
overnight accommodations; shared parking with other uses is permitted
|
Restaurant or assembly hall
|
1 for every 200 square feet of floor area
|
Retail business
|
1 for every 250 square feet or 1 for every 100 square feet of
floor area for retail establishments that collectively occupy more
than 30%, by area of the building in which they are situated
|
Bank, professional office, or business office
|
3 for every 1,000 square feet of floor area. In addition, where
a drive-in facility and/or automated banking machine is to be included,
6 in-line motor vehicles waiting spaces for each bank teller or remote
teller station or window; shared parking with other uses is permitted
|
Bus or railroad passenger terminal
|
1 for every 500 square feet of floor area
|
Personal service shops
|
1 for every 100 square feet of floor area
|
Meeting room facilities
|
1 for every 5 seats provided
|
Fitness center, health club
|
1 for every 100 square feet of floor area
|
Square Feet of Aggregate Gross Floor Area Devoted to Such Use
|
Number of Loading Spaces Required
|
---|---|
Up to and including 100,000
|
1
|
Over 100,000 up to and including 200,000
|
2
|
Over 200,000 up to and including 500,000
|
3
|
For each additional 200,000 or fraction thereof
|
1 additional
|