The following minimum standards shall apply for all construction
and development proposed within any identified floodplain area:
A. Fill. If fill is used, it shall:
(1) Extend laterally at least 15 feet beyond the building line from all
points;
(2) Consist of soil or small rock materials only; sanitary landfills
shall not be permitted;
(3) Be compacted to provide the necessary permeability and resistance
to erosion, scouring or settling;
(4) Be no steeper than one foot vertical to two feet horizontal, unless
substantiated data justifying steeper slopes are submitted to and
approved by the Floodplain Administrator; and
(5) Be used to the extent to which it does not adversely affect adjacent
properties.
B. Drainage facilities. Storm drainage facilities shall be designed
to convey the flow of stormwater runoff in a safe and efficient manner.
The system shall ensure proper drainage along streets and shall provide
positive drainage away from buildings. The system shall also be designed
to prevent the discharge of excess runoff onto adjacent properties.
C. Water and sanitary sewer facilities and systems.
(1) All new or replacement water and sanitary sewer facilities and systems
shall be located, designed and constructed to minimize or eliminate
flood damages and the infiltration of floodwaters.
(2) Sanitary sewer facilities and systems shall be designed to prevent
the discharge of untreated sewage into floodwaters.
(3) No part of any on-site sewage system shall be located within any
identified floodplain area except in strict compliance with all state
and local regulations for such systems. If any such system is permitted,
it shall be located so as to avoid impairment to it or contamination
from it during a flood.
D. Other utilities. All other utilities, such as gas lines and electrical
and telephone systems, shall be located, elevated (where possible)
and constructed to minimize the chance of impairment during a flood.
E. Streets. The finished elevation of all new streets shall be no more
than one foot below the regulatory flood elevation.
F. Storage. All materials that are buoyant, including but not limited to storage of wood, logs, timber, aboveground swimming pools, structures for housing animals or swing sets, flammable, explosive or, in times of flooding, could be injurious to human, animal or plant life and are not listed in §
86-29 shall be stored at an elevation of two feet above the regulatory flood elevation and/or floodproofed to the maximum extent possible.
G. Placement of buildings and structures. All buildings and structures
shall be designed, located and constructed so as to offer the minimum
obstruction to the flow of water and shall be designed to have a minimum
effect upon the flow and height of floodwater.
H. Anchoring.
(1) All buildings and structures shall be firmly anchored, in accordance
with accepted engineering practices, to prevent flotation, collapse
or lateral movement.
(2) All air ducts, large pipes, storage tanks and other similar objects
or components located below the regulatory flood elevation shall be
securely anchored or affixed to prevent flotation.
I. Floors, walls and ceilings.
(1) Wood flooring used at or below the regulatory flood elevation shall
be installed to accommodate a lateral expansion of the flooring, perpendicular
to the flooring grain, without causing structure damage to the building.
(2) Plywood used at or below the regulatory flood elevation shall be
of a marine or water-resistant variety.
(3) Walls and ceilings at or below the regulatory flood elevation shall
be designed and constructed of material that is water-resistant and
will withstand inundation.
(4) Windows, doors and other components at or below the regulatory flood
elevation shall be made of metal or other water-resistant material.
J. Paints and adhesives.
(1) Paints and other finishes used at or below the regulatory flood elevation
shall be of a marine or water-resistant quality.
(2) Adhesives used at or below the regulatory flood elevation shall be
of a marine or water-resistant variety.
(3) All wooden components (doors, trim, cabinets, etc.) shall be finished
with a marine or water-resistant paint or other finishing material.
K. Electrical components.
(1) Electrical distribution panels shall be at least three feet above
the one-hundred-year-flood elevation.
(2) Separate electrical circuits shall serve lower levels and shall be
dropped from above.
L. Equipment. Water heaters, furnaces, air-conditioning and ventilating
units and other electrical, mechanical or utility equipment or apparatus
shall not be located below the regulatory flood elevation.
M. Fuel supply systems. All gas and oil supply systems shall be designed
to prevent the infiltration of floodwaters into the system and discharge
from the system into floodwaters. Additional provisions shall be made
for the drainage of these systems in the event that floodwater infiltration
occurs.
All subdivision proposals and development proposals containing
at least 50 lots or at least five acres, whichever is the lesser,
in flood hazard areas where base flood elevation data are not available
shall be supported by hydrologic and hydraulic engineering analyses
that determine base flood elevations and floodway information. The
analyses shall be prepared by a licensed professional engineer in
a format required by FEMA for a conditional letter of map revision
or letter of map revision. Submittal requirements and processing fees
shall be the responsibility of the applicant.