This plan shall be an update of the sketch plan that was selected
and approved by the Village Board of Solvay. The proposed plan shall
contain:
A. Title, scale, north arrow and date.
B. Sheet size and scale, 24 inches by 36 inches, one inch equals 50
feet.
C. Bearings and distances of tract boundary lines and reference to horizontal
control points.
D. Locations and dimensions existing and proposed:
(1) Sections into which the final plat is to be divided, if to be drawn
in more than one section.
(2) Streets, public facilities or land, easements and similar features.
(3) Facilities or land dedicated to public use.
(4) Utilities on and adjacent to the tract, including sanitary, storm
and combined sewers, water mains, gas lines, fire hydrants, electric
and telephone facilities, and streetlights, invert elevation of sewers
at proposed points of connection and the location of all sewers not
adjacent to tract but to which connections are proposed, together
with invert elevations at points of connection.
E. Topography of subdivisions shall be included as follows:
(1) For land with an average slope of less than 2%, existing contour
lines at not more than one-foot intervals.
(2) For land with an average slope of 2% to 10%, existing contour lines
at not more than two-foot intervals.
(3) For land with an average slope exceeding 10%, existing contour lines
at not more than five-foot intervals.
(4) Datum plane for all topographic information shall be that of the
United States Geological Survey. Benchmarks used shall be indicated
by location and elevation.
F. Location of percolation test sites, if required.
G. Names or filed map numbers of:
(1) Owners of adjoining land.
H. Location and neighborhood maps must be provided and shall contain:
(1) Subdivision location and boundaries.
(2) Location of adjoining tracts and subdivisions, existing and proposed
streets, public facilities, and watercourses within 400 feet of any
part of the subdivision.
(3) Scale, which may vary from one inch equals 100 feet to one inch equals
200 feet.
I. Development data shall contain:
(1) Corrected and updated development data from sketch plan, or as required
by sketch plan.
(2) Results of any percolation tests.
(3) Drawings showing:
(a)
Proposed street cross sections and center line profiles.
(b)
Preliminary sketches of any bridges or culverts.
(c)
General feasibility of sewer design and stormwater drainage.
J. General plans of water distribution systems.
K. Legal data shall contain:
(1) Draft restrictions of all types which will run with the land to become
covenants in the deed for lots.
(2) Drafts of offers of cession, as required.
(3) Applications for public hearing, obtained from the Village Clerk.
L. Time schedule of operations.
M. Preliminary storm drainage report.